COMPLIANCE INFO 2008 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
707
>
2300 - Underground Storage Tank Program
>
PR0505735
>
COMPLIANCE INFO 2008 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2023 3:29:34 PM
Creation date
11/8/2018 9:53:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2015
RECORD_ID
PR0505735
PE
2361
FACILITY_ID
FA0006972
FACILITY_NAME
TSI TRANS SYSTEM INC
STREET_NUMBER
707
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231-9774
APN
19332008
CURRENT_STATUS
01
SITE_LOCATION
707 E ROTH RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\R\ROTH\707\PR0505735\COMPLIANCE INFORMATION 2008 - 2015.PDF
QuestysFileName
COMPLIANCE INFORMATION 2008 - 2015
QuestysRecordDate
6/29/2018 3:29:31 PM
QuestysRecordID
3930717
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5 WRCB,January 2002 Page_of <br /> 7. UNDER-DISPENSER CONTAINIUNT UDC TESTING <br /> Test Method Developed By: I UDC Manufacturer 11 Industry Standard X Professional Engineer <br /> U Other(Specify) <br /> Test Method Used: LI Pressure 1-1 Vacuum X Hydrostatic <br /> D Other(Sped) <br /> Test Lquipment Used: Caldwell Systems Equipment Resolution: .005/30 min <br /> � .. '::iaS215M"' lY.::I•�Aji•^.. W.,ll��:'. +�.... . .rai..v ,.:.wn8CA543`L9Th+'.Ci,e.Y�a •..••_3.v.�-. uL51%:h."Wfo'v b^ <br /> ; % UDC#1&2 UDC#Sate 1 UDC#Sate 2 UDC# <br /> UDC ManuracLurer: Bravo Bravo Brava <br /> UDC Material: Fiberglass Fiberglass Fiberglass <br /> UDC Depth: 28" 3C• 27" <br /> Height from UDC Bottom to Top 8" 10" T' <br /> of Highest Piping Penetration: <br /> Height I-om UDC Bottom to 7" 12" 10" <br /> Lowest lectrical Penetration: <br /> Conditin ofUDC prior to Dry Dry Dry <br /> testing: <br /> Portion if UDC Tested 2"above Highest Piping Penetration <br /> Does tui bine shut down when <br /> UDC se or detects liquid(both xYes LINO DNA xYes I'INo Fl NA xYes fl No IINA fl Yes CINo UNA <br /> roduct'.. nd water)?' <br /> Turbine shutdown response time <br /> Is syste programmed for fail- x Yes D No UNA x Yes D No D NA x Yes IINo riNA Dyes r1No UNA <br /> safe sh own? <br /> Wasfai-saFeverifiedtobe DYes xNo DNA nYes xNo nNA t7 Yes xNo UNA ❑Yes LINO UNA <br /> o erati nal? <br /> Wait tir e between apply ing <br /> pressure vacuum/water and 5 min 5 min 5 min 5 min <br /> starting test <br /> Test StartTime: 11:15 11:10 12:00 <br /> Initial Reading(Rt): .00" 1 .00" 1 .00" .00" <br /> Test End Time: 11:45 11:40 12:30 <br /> Final Reading r): .00 .00 .00 <br /> Test Duration: 30 min 30 min 30 min 30 min <br /> Chan a in Reading(Rr Rt): .00 .00 .00 <br /> Pass/Fail Threshold or Criteria: .005/30 min .005/30 min .005130 min .005/30 min <br /> Test Result: x Pass D Fal x Pass D Fail x Pass D rail D Pass D Rail <br /> Was sensor removed for testing? xYes LINO UNA xYes LINO I-INA xYes ONO DNA xYes FINo UNA <br /> Was sensor properly replaced and xYes LINO DNA xYes ONo UNA xYes NNo UNA xYes LINO TINA <br /> verified Functional after testing' <br /> Comments—(include information on repairs made prior to testing, and recommended follmv-upforfailed lews) <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(")is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />