My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
707
>
2300 - Underground Storage Tank Program
>
PR0505735
>
COMPLIANCE INFO 2008 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2023 3:29:34 PM
Creation date
11/8/2018 9:53:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2015
RECORD_ID
PR0505735
PE
2361
FACILITY_ID
FA0006972
FACILITY_NAME
TSI TRANS SYSTEM INC
STREET_NUMBER
707
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231-9774
APN
19332008
CURRENT_STATUS
01
SITE_LOCATION
707 E ROTH RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\R\ROTH\707\PR0505735\COMPLIANCE INFORMATION 2008 - 2015.PDF
QuestysFileName
COMPLIANCE INFORMATION 2008 - 2015
QuestysRecordDate
6/29/2018 3:29:31 PM
QuestysRecordID
3930717
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring' System Certification ' • <br /> D. Results of'llesting/Servicing <br /> Software V rsion Installed; <br /> Complete t ie following checklist: <br /> x)Yes Nn* Fis the audible alann operational? <br /> dX1 Yes 3 No* I Is the visual alarm operational? <br /> x Yes 3 No* Were all sensors visually inspected,functionally tested,and confirmed n erational? <br /> (x)Yes 3 No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper o enation? <br /> ( )Yes ) No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> x) N/A operational? <br /> (x)Ves ) No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ) N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? if yes: which sensors initiate <br /> Positive shut-down? (Check all that apply) IM Sump/Trench Sensors; ❑O Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? Il Yes; ❑No. <br /> O <br /> Yes ) No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> Fill point(s)and operating ro rl 7 if so at what percent of tank capacity does the alarm trio ger? % <br /> ( )Yes* ) No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E, below. <br /> ( )Yes* t) No Was liquid found inside any secondary containment systems designed as dry systems7 (Check all that apply) ❑ <br /> Product; ❑ Water, If yes, describe causes in Section F.,below. <br /> x Yes I No* Was monitoring-s stem set u reviewed to ensure re er settin s?Attach setue reports,if applicable <br /> x Yes I No" Is all monitoring equipment oerational per manufacturer's specifications? <br /> * In Section'F below,describe how and when these deficiencies were or will be corrected. <br /> U1. colnments: <br /> Pagc z ora 03101 <br />