My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
707
>
2300 - Underground Storage Tank Program
>
PR0505735
>
COMPLIANCE INFO 2008 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2023 3:29:34 PM
Creation date
11/8/2018 9:53:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2015
RECORD_ID
PR0505735
PE
2361
FACILITY_ID
FA0006972
FACILITY_NAME
TSI TRANS SYSTEM INC
STREET_NUMBER
707
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231-9774
APN
19332008
CURRENT_STATUS
01
SITE_LOCATION
707 E ROTH RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\R\ROTH\707\PR0505735\COMPLIANCE INFORMATION 2008 - 2015.PDF
QuestysFileName
COMPLIANCE INFORMATION 2008 - 2015
QuestysRecordDate
6/29/2018 3:29:31 PM
QuestysRecordID
3930717
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB January 2002 Page_of <br /> 4. TANK ANNULAR TESTING <br /> Test Met iod Developed By: x Tank Manufacturer G Industry Standard I l Professional Engineer <br /> ❑Other(Specify) <br /> Test Met md Used: ❑Pressure x Vacuum 11 Hydrostatic <br /> ❑Other(Spec) <br /> Test F.qu pment Used: Dwyer Manometer Equipment Resolution: +/-2% <br /> Tank# I Tank# Tank# Tank# <br /> Is Tank Exempt From Testing?' 0 Yes x No !I Yes fl No I !Yes 11 No Yes .No <br /> Tank Capacity: 10,000 <br /> Tank Material- Fiberglass <br /> Tank Manufacturer: Unknown <br /> Product Stored: Diesel <br /> Wait tim betweenapplying <br /> pressure acuum/waler and 30 min 30 min 30 min 30 min <br /> starting test; <br /> Test St Time: 11:30 <br /> Initial Reading(R): 7.23 <br /> Test End Time: 12:30 <br /> Final Reading(RF): 6.77 <br /> Test Duration: 1 hour I hour 1 hour I hour <br /> Change in Reading(RF-R[): .46 <br /> Pass/Fail Threshold or Criteria: No less than 1" No less than I" No less than 1" No less than I" <br /> Test Result: x Pass ❑Fail ❑ Pass ❑Fail ❑ Pass D Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? x Yes I-I No fl NA x Yes ❑No DNA x Yes ':_I No ❑NA x Yes IJNo I—NA <br /> Was sensor properly replaced and x Yes 11 No U NA x Yes ❑No FI NA x Yes I l No NA x Yes ❑No <br /> verified functional after <br /> 7 JNA <br /> COM14 nts—(include information on repairs made prior to testing, and recommended follow-up or ailed tests <br /> Secondaly containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containm nt,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. ( alifornia Code of Regulations,Title 23,Section 2637(a)(6)) <br />