Laserfiche WebLink
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br />-1P7bnknaiggy <br />TEST DATE: 03/02/06 8501 N MOPAC EXPRESSWAY, SUITE 400 <br />AUSTIN, TEXAS 78759 (512) 451-6334 WORK ORDER NUMBER: 2241243 <br />CLIENT: CONOCO-PHILLIPS SITE: CONOCO PHILLIPS #2708671 <br />rANK TEST RESULTS Test Method: NONE <br />PSI at tank bottom: <br />Fluid level in inches: <br />UFT/OFT: <br />Fluid volume in gallons: <br />Tank water level in inches: <br />Test time: <br />Number of thermisters: NOT <br />Specific gravity: TESTED <br />Water table depth in inches: <br />Determined by (method): <br />Leak rate in gph: <br />Result: <br />COMMENTS <br />ULLAGE TEST RESULTSTest Method: NONE <br />Test time: <br />Ullage volume: <br />Ullage pressure: <br />Results: <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: NOT <br />Flow rate (cfh): TESTED <br />Time of test 2: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 3: <br />Temperature: <br />Flow rate (cfh): <br />COMMENTS <br />LEAK DETECTOR TEST RESULTS Test method: <br />Test type: <br />B <br />TANK INFORMATION <br />Tank ID: <br />UNL 3 <br />Tank manifolded: NO <br />Bottom to top fill in inches: <br />Product: <br />UNLEADED <br />Vent manifolded: NO <br />Bottom to grade in inches: <br />Capacity in gallons: <br />9,816 <br />Vapor recovery manifolded: YES <br />Fill pipe length in inches: <br />Diameter in inches: <br />91.00 <br />Overfill protection: YES <br />Fill pipe diameter in inches: <br />Length in inches: <br />353 <br />Overspill protection: YES <br />Stage I vapor recovery: DUAL <br />Material: <br />DW FIBERG <br />Installed: ATG <br />Stage II vapor recovery: ASSIST <br />CP installed on: <br />COMMENTS <br />rANK TEST RESULTS Test Method: NONE <br />PSI at tank bottom: <br />Fluid level in inches: <br />UFT/OFT: <br />Fluid volume in gallons: <br />Tank water level in inches: <br />Test time: <br />Number of thermisters: NOT <br />Specific gravity: TESTED <br />Water table depth in inches: <br />Determined by (method): <br />Leak rate in gph: <br />Result: <br />COMMENTS <br />ULLAGE TEST RESULTSTest Method: NONE <br />Test time: <br />Ullage volume: <br />Ullage pressure: <br />Results: <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: NOT <br />Flow rate (cfh): TESTED <br />Time of test 2: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 3: <br />Temperature: <br />Flow rate (cfh): <br />COMMENTS <br />LEAK DETECTOR TEST RESULTS Test method: <br />Test type: <br />B <br />New/passed Failed/replaced New/passed Failed/replaced <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />Make: <br />VAPORLESS <br />Model: <br />LD2000 <br />S/N: <br />unreadable <br />Open time in sec: <br />2.00 <br />Holding psi: <br />27 NOT <br />Resiliency cc: <br />125 TESTED <br />est leak rate ml/m: <br />189.0 <br />Metering psi: <br />13 <br />Calib. leak in gph: <br />3.00 <br />Results: <br />PASS <br />COMMENTS <br />LINE TEST R <br />Material: <br />Diameter (in): <br />Length (ft): <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />Start time: <br />End time: <br />Final gph: <br />Result: <br />Pump type: <br />Pump make: <br />COMMENTS <br />rs <br />A <br />Test type: <br />B <br />DW FIBERG <br />2.0 <br />60.0 <br />NOT <br />NOT <br />TESTED <br />TESTED <br />PRESSURE <br />RED JACKET <br />TLD -1 <br />NOT <br />TESTED <br />Impact Valves Operational: UNKNOWN <br />Printed 03/17/2006 07:59 SBOWERS <br />NOT <br />TESTED <br />