My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2003 - 2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
8606
>
2300 - Underground Storage Tank Program
>
PR0232261
>
COMPLIANCE INFO 2003 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 1:10:35 PM
Creation date
11/8/2018 9:54:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003 - 2006
RECORD_ID
PR0232261
PE
2361
FACILITY_ID
FA0002590
FACILITY_NAME
THORNTON 76
STREET_NUMBER
8606
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
07242019
CURRENT_STATUS
01
SITE_LOCATION
8606 THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\THORNTON\8606\PR0232261\COMPLIANCE INFO 2003 - 2006.PDF
QuestysFileName
COMPLIANCE INFO 2003 - 2006
QuestysRecordDate
2/27/2018 6:46:39 PM
QuestysRecordID
3808828
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
302
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITQ,RING SYSTEM CEMT ,F TION <br />se By All Jurisdictions Within the State of Calif'! <br />Authority Cited: Chapter 6.7, HlWth and Safety Code; Chapter 16, Division 3 Title 23, Momia Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility, a separate <br />certification or report must be prepared for each monitorinq system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: CONOCO PHILLIPS #2708671 <br />Site Address: 8606 THORNTON ROAD <br />Facility Contact Person: MANAGER <br />Make/Model of Monitoring System:TLS350 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced <br />City: STOCKTON <br />Contact Phone No: 478-8959 <br />Date of Testing/Service: 03/02/2006 <br />Work Order Number: 2241243 <br />CA Zip: 95209 <br />Tank ID: 1 <br />Tank ID: 2 <br />X In -Tank Gauging Probe. <br />Model: MAG <br />X In -Tank Gauging Probe. <br />Model: MAG <br />X Annular Space or Vault Sensor. <br />Model: 407 <br />Annular Space or Vault Sensor. <br />Model: 407 <br />X Piping Sump/Trench Sensor(s). <br />Model: 208 <br />Piping Sump/Trench Sensor(s). <br />Model: 208 <br />Fill Sump Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />Mechanical Line Leak Detector. <br />Model: LD2000 <br />Mechanical Line Leak Detector. <br />Model: LD2000 <br />Electronic Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and <br />model in Section E on page 2). <br />Other (specify equipment type and model in Section E on page 2). <br />Tank ID: 3 <br />Tank ID: <br />X In -Tank Gauging Probe. <br />Model: MAG <br />In -Tank Gauging Probe. <br />Model: <br />X Annular Space or Vault Sensor. <br />Model: 407 <br />Annular Space or Vault Sensor. <br />Model: <br />X Piping Sump/Trench Sensor(s). <br />Model: 208 <br />Piping Sump/Trench Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />X Mechanical Line Leak Detector. <br />Model: MLD <br />Mechanical Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Tank Overril/High-Level Sensor. <br />Model: <br />Other (specify equipment type and <br />model in Section E on page 2). <br />7 Other (specify equipment type and model in Section E on page 2). <br />Dispenser : 1/2 <br />Dispenser ID: 3/4 <br />❑ Dispenser Containment Sensor(s) <br />Model: <br />Dispenser Containment Sensor(s) <br />Model: <br />X❑ Shear Valve(s). <br />X Shear Valve(s) <br />MDispenser Containment Float(s) and Chain(s). <br />X Dispenser Containment Float(s) and Chain(s). <br />Dispenser lD: <br />Dispenser ID: <br />FiDispenser Containment Sensor(s) <br />Model: <br />Dispenser Containment Sensor(s). <br />Model: <br />F]Shear Valve(s). <br />Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser lD: <br />Dispenser lD: <br />F]Dispenser Containment Sensor(s) <br />Model: <br />Dispenser Containment Sensor(s). <br />Model: <br />Shear Valve(s). <br />Shear Valve(s). <br />ID Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification <br />I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this certification is information (e.g manufacturers' checklists) necessary to verify that this information is correct. <br />and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached <br />a copy of the (Check all that apply): ❑X System set-up X❑ Alarm history report <br />Technician Name (print): RHOME DESBIENS <br />Certification No.: 1938 <br />Signature: <br />License. No.: <br />Testing Company Name:Tanknology Phone No.: (800) 800-4633 <br />Site Address: 8501 N. MoPac Expressway, suite 400, Austin, TX 78759 Date of Testing/Servicing: 03/02/2006 <br />Monitoring System Certification Page 1 of 3 Based on CA form dated 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.