My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
8606
>
2300 - Underground Storage Tank Program
>
PR0232261
>
COMPLIANCE INFO 2007 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 1:19:49 PM
Creation date
11/8/2018 9:54:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2010
RECORD_ID
PR0232261
PE
2361
FACILITY_ID
FA0002590
FACILITY_NAME
THORNTON 76
STREET_NUMBER
8606
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
07242019
CURRENT_STATUS
01
SITE_LOCATION
8606 THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\THORNTON\8606\PR0232261\COMPLIANCE INFO 2007 - 2010.PDF
QuestysFileName
COMPLIANCE INFO 2007 - 2010
QuestysRecordDate
2/27/2018 5:13:36 PM
QuestysRecordID
3808429
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
345
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 i Page 5 <br /> 7. UNDER-DISPENSER CONTAINMENT (UDC) TESTING <br /> Test Method Developed By: ❑ UDC Manufacturer ❑ Industry Standard X❑ Professional Engineer <br /> Other (Specify) <br /> Test Method Used: Pressure ❑ Vacuum Hydrostatic <br /> Other (Specify) <br /> Test Equipment Used: vp1t Equipment Resolution: .05gph <br /> UDC# 1/2 UDC# 3/4 UDC# UDC# <br /> UDC Manufacturer: bravo bravo <br /> UDC Material: metal metal <br /> UDC Depth: 81, 811 <br /> Height from UDC Top to Top of 01' 01, <br /> Highest Piping Pentration: <br /> Height from UDCTop to Lowest 01, off <br /> Electrical Pentration: <br /> Condition of UDC prior to testing: good good <br /> Portion of UDC Tested: 1 211 211 <br /> Does turbine shut down when <br /> sump sensor detects liquid(both XUYes UNoUN ❑Yes UNo❑N ❑Yes UNoUN []Yes UNoa <br /> product and water)?* <br /> Turbine shutdown response time: 2-5 secs 2-5 sec s <br /> Is system programmed for fail-safe ❑ ❑ � [:]Yes <br /> X] ^ ❑ ❑ � []Yes <br /> ❑ <br /> shutdown?* Yes N N Yes NUON Yes N N Yes No <br /> Was fail-safe verified to be ❑ ❑ " ❑ ❑ ^ [:]Yes <br /> ❑ � ❑ ❑ <br /> operational?* Yes N �N Yes NOUN Yes X N N Yes No <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 min 5 min <br /> test: <br /> Test Start Time: 9:2 5 9:2 7- <br /> Initial Reading(R1): 8.489 3 .734 <br /> Test End Time: 9:40 9:42 <br /> Final Reading(RF): 8.465 3.658 <br /> Test Duration: 15 min 15 min <br /> Change in Reading(R F-R1 ): .0 0 2 gph .0 0 9hph <br /> Pass/Fail Threshold or Criteria: .05gph 05gph <br /> T Lw ',. ✓�yi--i a fi`dIri i .5 1[ <br /> Was sensor removed for testing. ❑Yes N^^�� ❑ X❑ ❑ ❑ []Yes❑NA Yes N NA Yes N NA No <br /> F7_--1 <br /> "U <br /> Was sensor properly replaced and ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ <br /> verified functional after testing? Ye N NA Ye N NA Ye N NA Yes N <br /> Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> staring and ending values are taken off the vplt <br /> 1 If the entire depth of the UDC is not tested,specify how much was tested.If the answer to any of the questions indicated with an <br /> asterisk(*)is "NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />