Laserfiche WebLink
RECEIVE <br /> Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.swrcb.ca.gov.)MAR U 4 20 15 <br /> MONITORING SYSTEM CERTIFICATION ENVIRONMENTAL <br /> For Use By All Jurisdictions Within the State of California MENTAL <br /> Authority Cited.,Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23,California Codeldf"-^^o+��,,,-�,� <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.Acopy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CHEVRON#98264(N-534) Bldg.No.: <br /> Site Address: 3775 N.TRACY BLVD City: TRACY Zip: 95376 <br /> Facility Contact Person: MGR-PAT Contact Phone No.: 209-836-9422 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing(Servicing: 2/17/2015 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: T1-SUPREME Tank ID: T2-PLUS <br /> r In-Tank Gauging Probe. Model: Mao r In-Tank Gauging Probe. Model: Mag <br /> r Annular Space or Vault Sensor. Model: 409 r Annular Space or Vault Sensor. Model: 409 <br /> r Piping Sump/Trench Sensor(s). Model: 208 r Piping Sump/Trench Sensor(s). Model: 206 <br /> r Fill Sump Sensor(s). Model: 208 r Fill Sump Sensor(s). Model: 208 <br /> r Mechanical Line Leak Detector. Model: r Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: Veeder Root PLLD r Electronic tine Leak Detector. Model: Veeder Root PLLD <br /> r Tank Overfill/High-Level Sensor.Model: Flapper r Tank Overfill/High-Level Sensor.Model: Flapper <br /> Other(specify equipment and model in Section E on Pae 2. Other(specify equipment and model in Section E on Pae 2). <br /> Tank ID: T3-REGULAR Tank ID: <br /> r In-Tank Gauging Probe, Model: Mag r In-Tank Gauging Probe. Model: <br /> WO Annular Space or Vault Sensor. Model: 409 r Annular Space or Vault Sensor. Model: <br /> W Piping Sump/Trench Sensor(s). Model: 208 r Piping Sump/Trench Sensor(s). Model: <br /> W Fill Sump Sensor(s). Model: 208 r Fill Sump Sensor(s). Model: <br /> F Mechanical Line Leak Detector. Model: r Mechanical Line Leak Detector. Model: <br /> (v Electronic Line Leak Detector, Model: Veeder Root PLLD r Electronic line Leak Detector. Model: <br /> jr Tank Overfill/High-Level Sensor.Model: Flapper r Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equipment and model in Section E on Pae 2. Other s eci equipment a and model in Section E on Pae 2). <br /> Dispenser 1j2 Dispenser 3/4 <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: 209 r Dispenser Containment Sensor(s).Model: 208 <br /> r Shear Valve(s). r Shear Valve(s). <br /> F Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Floats and Chain(s). <br /> Dispenser 5/6 Dispenser 7/8 <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: 208 r Dispenser Containment Sensor(s).Model: 208 <br /> P Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Floats and Chains. r Dispenser Containment Floats and Chain(s). <br /> Dispenser 9/10 Dispenser 11/12 <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: 208 r Dispenser Containment Senwr(s).Model: 218 <br /> V Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). Dispenser Containment Floats and Chain(s). <br /> "If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-1 certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply):r System set- <br /> up r Alarm history report <br /> pal <br /> i' <br /> Technician Name(print): Ryan Casey Signature: i <br /> Certification No.: 838961 License.No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)8004633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 2/17/2015 <br /> Monitoring System Certification Page 1 of 3 12/07 <br />