My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3775
>
2300 - Underground Storage Tank Program
>
PR0231418
>
COMPLIANCE INFO 2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:19:01 PM
Creation date
11/8/2018 9:55:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231418
PE
2361
FACILITY_ID
FA0003715
FACILITY_NAME
Tracy Blvd Chevron
STREET_NUMBER
3775
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
3775 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TRACY\3775\PR0231418\COMPLIANCE INFO\COMPLIANCE INFO 2012-2015.PDF
QuestysFileName
COMPLIANCE INFO 2012-2015
QuestysRecordDate
10/10/2017 8:57:48 PM
QuestysRecordID
3096410
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br /> MAR 0 4 2015 <br /> D.Results of Testing/Servicing <br /> Software Version Installed: 328.03 FNVIRONMENTA!. <br /> �gn.rury— <br /> Complete the following checklist: <br /> * Yes r No' s the audible alarm operational? <br /> • Yes r No* s the visual alarm operational? <br /> • Yes r No* Nere all sensors visually inspected,functionally tested,and confirmed operational? <br /> • Yes r No. Nere all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere wit <br /> heir proper operation? <br /> Yes r No' f alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> • N/A <br /> yes r No- or pressurized piping systems,does the turbine automatically shut down if the piping secondary containment monitoring <br /> "Ystern detects a leak,fails to operate,or is electrically disconnected?If yes:which sensors initiate positive shut-down?(Check <br /> N/A 11 that applyr Sump/Trench Sensors; r Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection?r, Yes; R No <br /> Yes - No" or tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no mechanical overfill <br /> revention valve is installed),is the overfill warning alarm visible and audible at the tank fill point(s)and operating properly?If <br /> • N/A o at what percent of tank capacity does the alarm trigger?% <br /> Yes* • No Nas any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment replaced and list the <br /> anufacturer name and model for all replacement parts in Section E below. <br /> • Yes" r No as liquid found inside any secondary containment systems designed as dry systems?(Check all that apply) <br /> Product r'Water.[f es describe causes in Section E below. <br /> • Yes No' as monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> ♦ Yes No. <br /> s all monitoring equipment operational per manufacturers specifications? <br /> •In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E.Comments: <br /> Very small amount of water was located in 91 Stp and Diesel Stp. <br /> Monitoring System Certification Page 2 of 3 12/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.