My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3775
>
2300 - Underground Storage Tank Program
>
PR0231418
>
COMPLIANCE INFO 2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:19:01 PM
Creation date
11/8/2018 9:55:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231418
PE
2361
FACILITY_ID
FA0003715
FACILITY_NAME
Tracy Blvd Chevron
STREET_NUMBER
3775
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
3775 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TRACY\3775\PR0231418\COMPLIANCE INFO\COMPLIANCE INFO 2012-2015.PDF
QuestysFileName
COMPLIANCE INFO 2012-2015
QuestysRecordDate
10/10/2017 8:57:48 PM
QuestysRecordID
3096410
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MAR 0 4 2015 <br /> F.In-Tank Gauging/SIR Equipment: r7.Check this box if tank gauging is used only for inventory control. <br /> r Check this box if no tank gauging or SIR equipmepbi�i' gdfONM ENTAD. <br /> This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. I V—�,�n_ <br /> Complete the following checklist: <br /> Yes NO las all input wiring been inspected for proper entry and termination,including testing for ground faults? <br /> Yes No* Nere all tank gauging probes visually inspected for damage and residue buildup? <br /> Yes No* Nas accuracy of system product level readings tested? <br /> Yes No* Nas accuracy of system water level readings tested? <br /> Yes No* Nere all probes reinstalled properly? <br /> Yes No* Nere all hems on the equipment manufacturer's maintenance checklist completed? <br /> *In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> G.Line Leak Detectors(LLD): r Check this box if LLDs are not installed. <br /> Complete the following checklist: <br /> • Yes No* or equipment start-up or annual equipment certifications was a leak simulated to verify LLD performance?(Check all that <br /> N/A pply)Simulated leak rate:*r 3 g.p.h.; r 0.1 g.p.h; 1 0.2 g.p.h. <br /> • Yes r No* Nere all LLDs confirmed operational and accurate within regulatory requirements? <br /> • Yes r No* Nas the testing apparatus properly calibrated? <br /> Yes r No' or mechanical LLDs,does the LLD restrict product Row if it detects a leak? <br /> • N/A <br /> • Yes r No* For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? <br /> N/A <br /> IT Yes r No' For electronic LLDs that are programmed for positive shut down,does the turbine automatically shut off if any portion of the <br /> N/A omboring system is disabled or disconnected? <br /> • Yes r <br /> No* or electronic LLDs that are programmed for positive shut down,does the turbine automatically shut off if any portion of the <br /> N/A onitonng system malfunctions or fails a test? <br /> IT Yes r No* or electronic LDS,have all accessible wiring connections been visually inspected? <br /> N/A <br /> • Yes r No* ere all items on the equipment manufacturer's maintenance checklist completed? <br /> *In the Section N,below,describe how and when these deficiencies were or will be corrected. <br /> N. Comments: <br /> First attempt of 87 Id did not pass.Purged under 2 gallons of fuel then 87 ld passed.No repairs needed. <br /> Page 3 of 3 12/07 <br />