My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1986-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
560
>
2300 - Underground Storage Tank Program
>
PR0231421
>
COMPLIANCE INFO 1986-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:39:24 PM
Creation date
11/8/2018 9:55:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-2007
RECORD_ID
PR0231421
PE
2381
FACILITY_ID
FA0003502
FACILITY_NAME
TRACY CITY PUBLIC WORKS
STREET_NUMBER
560
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23515006
CURRENT_STATUS
02
SITE_LOCATION
560 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TRACY\560\PR0231421\COMPLIANCE INFO 1986-2007.PDF
QuestysFileName
COMPLIANCE INFO 1986-2007
QuestysRecordDate
8/18/2017 3:15:11 PM
QuestysRecordID
3590253
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
242
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FROM - - • • <br /> Magloatostrictive <br /> TLS Tank Monitoring <br /> Certified performance for inventory control and in-tank leA Qi <br /> detection gasolines, diesel <br /> approved <br /> f r, <br /> ry . Highly accurate Magne- NEW!Series 8473 MAG 2 Probe <br /> tostrictive measurement The new MAG 2 probe provides the same reliability, <br /> q technology inventory control features and fluid compatibility as <br /> �. <br /> s <br /> >j ► Fast, accurate leak tests the MAG 1 probe, but offers 0.2 GPH leak detection <br /> at a lower cost. It's ideal for people who want MAG <br /> i , <br /> ► MAG 1(0.1 GPH)and probe performance with 0.2 GPH monthly monitoring <br /> NEW MAG 2(0.2 GPH) capability. <br /> r; I <br /> �,, probes available <br /> t ' <br /> MAG 1 probe third-party The new MAG 2 probe has also been third-party <br /> certified to exceed U.S. tested and certified to perform far better than the U.S. <br /> E.P.A. performance E.P.A. standards for 0.2 GPH automatic tank gauging. <br /> standards for 0. GPH See the summary of leak test performance on back <br /> Volumetric Tank Tight- or call us for a copy of the complete test results. <br /> ness Testing MAG 1 Probe and the TLS-350 with CSLD — <br /> ► MAG 1 probe compatible Leak detection without shutting down your tacks! <br /> with TLS-350 with CSLD CSLD, Continuous Statistical Leak Detection, is a . <br /> for continuous statistical new, advanced tank testing technology that makes full <br /> leak detection use of the TLS-350's in-tank monitoring capabilities. <br /> ► MAG 2 probe third-party CSLD eliminates the need for tank shutdown to per- <br /> certified to exceed U.S. form a leak test— no lost business, no lost <br /> E.P.A. performance <br /> operating time! f <br /> standards for 0.2 GPH The TLS-350 with CSLD uses the MAG 1 probe to <br /> Automatic Tank Gauging continuously monitor fuel height and temperature <br /> ► Compatible with information to detect idle times in the tank. During <br /> gasolines, diesel and each idle time, data is collected and combined with <br /> other approved fluids information from other idle periods to form a highly <br /> MAG 1 MAG 2 accurate leak detection database. Sophisticated <br /> ► Water measurement statistical analysis techniques in CSLD constantly <br /> capability evaluate the database to discard invalid data and <br /> ► 2"and 4"Float Kits available perform leak tests based on only high-quality informa- <br /> tion in the current database. In fact, a new leak test <br /> Series 8473 MAG 1 Probe is performed every time new data from an idle period <br /> The MAG 1 probe provides highly accurate, trouble- is added. <br /> free performance in gasolines, diesel and a wide <br /> variety of approved fluids. Its magnetostrictive tech- It's the next generation in leak detection technology <br /> nology and five-point temperature sensing make it made possible, in part, by the accuracy of the - <br /> capable of extremely accurate inventory control and MAG 1 probe! <br /> in-tank leak testing. <br /> Approved for Aboveground Tank Applications <br /> The MAG 1 probe has been third-party tested and Veeder-Root Magnetostrictive Probes are approved <br /> certified to perform far better than the U.S. E.P.A. for use in aboveground storage tanks to monitor fuel <br /> standards for both 0.1 GPH volumetric tank tightness inventory. An AST Installation Kit (Form Number <br /> testing and 0.2 GPH automatic tank gauging. See the 312020-984) is required for these applications and is <br /> summary of leak test performance on back or call us available from Veeder-Root or your authorized <br /> for a copy of the complete test results. Veeder-Root distributor. <br /> 4 <br />