Laserfiche WebLink
Underground Storage Tank Program Inspection Report <br />Date: <br />September 05, 2017 <br /> Facility Address: <br /> 20 W TURNER RD, LODI <br /> Facility Name: <br /> SHORT STOP FOOD MART <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />UST System Observations <br /> 322 □ V □ R □ COSUnburied below grade emergency generator system failed to meet exemption statusHSC 25281.6(a) <br /> 323 □ V □ R □ COSUnburied below grade UST system failed to meet exemption statusHSC 25283.5(a) <br /> 324 □ V □ R □ COSTampered with red tagCCR 2717.1(g) <br /> 325 □ V □ R □ COSDeposited petroleum into a red tagged USTCCR 2717.1(f) <br /> 326 □ V □ R □ COSTampered with or disabled leak detection devices or alarmsHSC 25299(a)(9) <br /> 327 □ V □ R □ COSUST system not compatible with the substance storedCCR 2631.1 <br /> 328 □ V □ R □ COSFailed to comply with temporary closure requirementsHSC 25298 <br /> 329 □ V □ R □ COSFailed to comply with permanent closure requirementsHSC 25298 <br /> 330 □ V □ R □ COSFailure to meet all requirements in lieu of a line leak detector for emergency generator tank systemCCR 2636(f)(6) <br />Single-Walled Non-Pressurized Piping <br /> 401 □ V □ R □ COSSuction piping not properly sloped or incorrectly located check valveCCR 2636(a)(3) <br /> 402 □ V □ R □ COSDaily monitoring of suction pipe (pre-Jan 1984) not performedCCR 2643(d) <br /> 403 □ V □ R □ COSTriennial 0.1 gph line test for conventional suction piping not performed (pre-January 1984)CCR 2643(d) <br /> 404 □ V □ R □ COSBiennial 0.1 gph test for gravity piping not performed (pre-January 1984)CCR 2643(e) <br />Other Violations <br /> 2010 □ V □ R □ COSUnlisted Administration/Documentation violation See below <br /> 2030 □ V □ R □ COSUnlisted Operations/Maintenance violation See below <br /> 2060 □ V □ R □ COSUnlisted Design/Construction violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br />UST Tank Information forms for Tank ID #TA0507912, #TA0507913, and #TA0507914 are not current in CERS. <br />Under Vent, Vapor Recovery (VR) and Riser / Fill Pipe Piping Construction, Riser Pipe Secondary Containment <br />should be single walled, not double walled. Any change of information must be updated in CERS within 30 days of <br />the changes. Immediately log into CERS, update the required information, and submit for review by the EHD. <br />This is a repeat violation, Class II. <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br />On August 9, 2017, there was a cold start performed on the system. The facility did not properly document the <br />alarms in the facility alarm log. <br /> These records shall be maintained on site for at least three years. Monitoring records include: (1) date and time of <br />all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any visual <br />observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other <br />monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings and <br />reconciliations. Immediately locate and maintain all maintenance and monitoring records for the last three years on <br />site and submit copies to the EHD. <br />This is a minor violation. <br />Page 3 of 6 <br />FA0000645 PR0231380 SC001 09/05/2017 <br />EHD 23-01 Rev. 09/22/16 Underground Storage Tank Program OIR