My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - PRESENT
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
20
>
2300 - Underground Storage Tank Program
>
PR0231380
>
COMPLIANCE INFO 2016 - PRESENT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2023 1:43:08 PM
Creation date
11/8/2018 9:56:31 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - PRESENT
RECORD_ID
PR0231380
PE
2361
FACILITY_ID
FA0000645
FACILITY_NAME
SHORT STOP FOOD MART
STREET_NUMBER
20
Direction
W
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04134015
CURRENT_STATUS
01
SITE_LOCATION
20 W TURNER RD # A
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TURNER\20\PR0231380\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
10/26/2016 4:14:22 PM
QuestysRecordID
3242119
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
173
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank Program Inspection Report <br />Date: <br />September 05, 2017 <br /> Facility Address: <br /> 20 W TURNER RD, LODI <br /> Facility Name: <br /> SHORT STOP FOOD MART <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br />An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br />accessible on site at all times. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br /> 205 CCR 2712(i) Failure to have an approved UST response plan available onsite. <br />An approved copy of the response plans were not available for inspection. A copy of these plans shall be <br />accessible on site at all times. <br />This was corrected on site. <br />This is a minor violation. <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions. <br />According to EHD records, a cold start was performed on August 9, 2017. Records of the cold start were not <br />located on site during the inspection. When performing a cold start, the EHD needs to be notified 48 hours in <br />advance. Proof the sensors were properly retested and copies of the certifications of the tester need to be kept on <br />site. Immediately obtain the required information and store them on site. <br />This is a minor violation. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator (DO) failed to document all the alarms from the attached alarm history on the 9/4/2017 <br />designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br />DO did not document the cold start that occurred on August 9, 2017. During the monthly inspection, the designated <br />operator shall review the alarm history for the previous month, check that each alarm was documented and <br />responded to appropriately, and attach a copy of the alarm history with documentation taken in response to any <br />alarms to the monthly report. Ensure that designated operators performing monthly inspections at this facility are <br />including all of the required information on the reports. <br />This is a minor violation. <br />Page 4 of 6 <br />FA0000645 PR0231380 SC001 09/05/2017 <br />EHD 23-01 Rev. 09/22/16 Underground Storage Tank Program OIR
The URL can be used to link to this page
Your browser does not support the video tag.