My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1985-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
930
>
2300 - Underground Storage Tank Program
>
PR0502817
>
COMPLIANCE INFO 1985-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:50:15 PM
Creation date
11/8/2018 9:58:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2006
RECORD_ID
PR0502817
PE
2361
FACILITY_ID
FA0005584
FACILITY_NAME
VALLEY PACIFIC LODI PLANT & CARDLOCK
STREET_NUMBER
930
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04905023
CURRENT_STATUS
01
SITE_LOCATION
930 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\V\VICTOR\930\PR0502817\COMPLIANCE INFO\COMPLIANCE INFO 1985-2006.PDF
QuestysFileName
COMPLIANCE INFO 1985-2006
QuestysRecordDate
5/19/2016 8:14:18 PM
QuestysRecordID
3086574
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
184
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 2 of 8 <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: U Tank Manufacturer M Industry Standard U Professional Engineer <br /> U Other(Spec) <br /> Test Method Used: U Pressure XI Vacuum U Hydrostatic <br /> U Other(Specify) <br /> Test Equipment Used: Vacuum Generator Ga es Equipment Resolution: <br /> Tank If 1 K 2 Tank# Tank# Tank# <br /> Is Tank Exempt From Testing?' U Yes Xl No U Yes U No U Yes U No U Yes U No <br /> Tank Capacity: 0 <br /> Tank Material: G1 ss Clad S eel <br /> Tank Manufacturer: lodern Weldin <br /> Product Stored: Re Su er <br /> Wait time between applying <br /> pressure/vacuum/water and i hr. <br /> z <br /> starting test: <br /> Test Start Time: 8:20 <br /> Initial Reading(R,): 7" HG <br /> Test End Time: 9:20 <br /> Final Reading(Rr): 7" HG <br /> Test Duration: <br /> Change in Reading(R, &): 0 <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: l KPass U Fail U Pass U Fail U Pass U Fail U Pass U Fall <br /> Was sensor removed for testing? K Yes U No U NAU Yes U No U NA U Yes U No U NA U Yes U No U NA <br /> Was sensor properly replaced and Yes-UNo U NA U Yea U No U NA U Yes U No U NA U Yes U No U NA <br /> verified functional after testing? <br /> Comments— (include information onOTirs made prj6r to testing, and recommended follow-up forfailed tests) <br /> ' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. (California Code of Regulations,Title 23,Section 2637(a)(6)) <br />