My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1985-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
930
>
2300 - Underground Storage Tank Program
>
PR0502817
>
COMPLIANCE INFO 1985-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:50:15 PM
Creation date
11/8/2018 9:58:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2006
RECORD_ID
PR0502817
PE
2361
FACILITY_ID
FA0005584
FACILITY_NAME
VALLEY PACIFIC LODI PLANT & CARDLOCK
STREET_NUMBER
930
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04905023
CURRENT_STATUS
01
SITE_LOCATION
930 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\V\VICTOR\930\PR0502817\COMPLIANCE INFO\COMPLIANCE INFO 1985-2006.PDF
QuestysFileName
COMPLIANCE INFO 1985-2006
QuestysRecordDate
5/19/2016 8:14:18 PM
QuestysRecordID
3086574
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
184
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
:002 Page,; of 6 <br /> 6. PIPING SUMP TESTING <br /> .i Developed By: ❑Sump Manufacturer _44ndustry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Method Used: ❑Pressure ❑Vacuum Hydrostatic <br /> ❑Other(Specify) <br /> fest Equipment Used: Zr l C, -=s 7`S Equipment Resolution: <br /> Sump# 7 Sump# Z Sump# SUMP# <br /> Sump Diameter: qj 4 tj Z tl <br /> Sump Depth: t4S h 8 H <br /> Sump Material: 7A P <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: <br /> Condition of sump prior to testing: , <br /> Portion of Sump Tested' <br /> Does turbine shut down when <br /> sump sensor detects liquid(both $Yes ❑No [INA AYes ❑No ❑NA ❑Yes ❑No [INA ❑Yes ❑No ❑NA <br /> product and water)?` <br /> Turbine shutdown response time <br /> Is system programmed for fail-safe <br /> shutdown?` 0Q Yes ❑No ❑NA Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ElNA <br /> Was fail-safe verified to be <br /> operational?* Yes ❑No ❑NA 4Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Wait time between applying <br /> pressure/vacuum/waterand starting <br /> test: <br /> Test Start Time: ;Q <br /> Initial Reading(R,): .5{ (� ;D�S ;Z <br /> Test End Time: (o -Z it 2.- & Z �i <br /> Final Reading(RF): _ S� 4f 2.CI;2 <br /> Test Duration: S , -A;. ;'I ja <br /> Change in Reading(RF-R,): 0,2 / -19 <br /> Pass/Fail Threshold or Criteria: —.of Z pJ7 Jv y r ooL <br /> Test Result: J6 Pass ❑Fail Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? AYes ❑No ❑NA JaYes ❑No ❑NA ❑Yes ❑No [INA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and G3Yes ❑No ❑NA Yes ❑No ❑NA ❑Yes El No El NA 11 Yes 11 No 11 NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> ' If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(")is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.