My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1985-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
930
>
2300 - Underground Storage Tank Program
>
PR0502817
>
COMPLIANCE INFO 1985-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:50:15 PM
Creation date
11/8/2018 9:58:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2006
RECORD_ID
PR0502817
PE
2361
FACILITY_ID
FA0005584
FACILITY_NAME
VALLEY PACIFIC LODI PLANT & CARDLOCK
STREET_NUMBER
930
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04905023
CURRENT_STATUS
01
SITE_LOCATION
930 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\V\VICTOR\930\PR0502817\COMPLIANCE INFO\COMPLIANCE INFO 1985-2006.PDF
QuestysFileName
COMPLIANCE INFO 1985-2006
QuestysRecordDate
5/19/2016 8:14:18 PM
QuestysRecordID
3086574
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
184
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.002 Page�of 6 <br /> 7. UNDER-DISPENSER CONTAINMENT DC TESTING <br /> Developed By: 0 UDC Manufacturer ;9.iudustry Standard 0 Professional Engineer <br /> 0 Other(Specify) <br /> ,ethod Used: - 0 Pressure 0 Vacuum AHydrostatic <br /> 0 Other(Specify) <br /> lest Equipment Used: (.v Y1 — S Equipment Resolution: , oc i <br /> UDC # 2 UDC# UDC# _ UDC # <br /> UDC Manufacturer: C w oa <br /> UDC Material: <br /> UDC Depth: ( VI 12 <br /> Height from UDC Bottom to TopD rl �I <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to D h h <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testing: <br /> Portion of UDC Tested <br /> Does turbine shut down when <br /> UDC sensor detectsliquid(both 1�Yes 0 No 0 NA ,✓ryes 0 No 0 NA 0 Yes 0 No DNA 0 Yes 0 No DNA <br /> product and water <br /> Turbine shutdown response time /I M 91'4- <br /> is <br /> Is system programmed for fail- li es 0 No 0 NA ,gYes 0 No 0 NA 0 Yes 0 No DNA .0 Yes 0 No 0 NA <br /> safe shutdown? Y <br /> Was fail-safe verified to be yes 0 No DNA *jYes 0 No DNA 0 Yes 0 No DNA 0 Yes 0 No DNA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and (S lM ILA �,�M t*e� <br /> starting test <br /> Test Start Time: 't't rn't <br /> Initial Readin (R,): 51l <br /> elgq <br /> Test End Time: :�'t • .b1 Final Readin (Rr): V ."to Test Duration:Chan a in Readin (Rr-R,): ,uo 01Pass/Fail Threshold or Criteria: •06y ao2 I""Test Result: L9'Pass 0Fail EPass 0 Fail 0 Pass 0 Fail 0 Pass 0 Fail <br /> Was sensor removed for testing? Yes 0 No 11-NA Yes 0 No 0 NA 0 Yes 0 No [INA 0 Yes 0 No DNA <br /> Was sensor properly replaced and yes 0 No 0 NA Yes 0 No 0 NA 0 Yes 0 No 0 NA 0 Yes 0 No DNA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any+of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire T)DC must be tested. (See SWRCB LG-160) <br />