My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1250
>
2300 - Underground Storage Tank Program
>
PR0231299
>
COMPLIANCE INFO 2005-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:09 PM
Creation date
11/8/2018 10:00:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2008
RECORD_ID
PR0231299
PE
2361
FACILITY_ID
FA0003972
FACILITY_NAME
THRIFTY OIL COMPANY
STREET_NUMBER
1250
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11731001
CURRENT_STATUS
02
SITE_LOCATION
1250 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WILSON\1250\PR0231299\COMPLIANCE INFO 2005-2008.PDF
QuestysFileName
COMPLIANCE INFO 2005-2008
QuestysRecordDate
5/24/2018 4:59:31 PM
QuestysRecordID
3904191
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IED PROGRAM CONSOLIDATED Fole <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN - Pae I of 3) <br /> TYPE OF ACTION ® 1.NEW PLAN ❑ 2.CHANGE OF INFORMATION 490-1. <br /> PLAN TYPE ® I.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490-2. <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): 490-2a. <br /> I. FACILITY INFORMATION <br /> FACILITY ID 4(Agency Use Only) 1 <br /> BUSINESS NAME(Same as Facility Name or DBA) 1 <br /> ARCO 09600 <br /> BUSINESS SITE ADDRESS 1250 N WILSON WAY 113. BUSINESS SITE CITY STOCKTON 04 <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> by theip <br /> equment manufacturers instructions,or annually,whichever is,more frequent Such work must be performed by qualified personnel.[23 CCR 42632,2634, 2641) <br /> ...... .. .. 2.63e ago 3e. <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY ❑ 99.OTHER(Specify): 490-3b <br /> III. MONITORING LOCATIONS <br /> ® L NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ❑ 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED [23 CCR§2632,2634] 490-4. <br /> IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) ;h hak,Y <br /> oj <br /> E I.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 4909. <br /> WITH AUDIBLE AND VISUAL ALARMS.[23 CCR§2632,2634] <br /> SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490.6, <br /> PANEL MANUFACTURER: Veeder Root 490-7 MODEL N: TLS-350 490-8 <br /> LEAK SENSOR MANUFACTURER: Veeder Root 490-9. MODEL H(S): 794390-420 490-10. <br /> --❑ 2 AJ1JT6_&fkT PC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).[23 CCR§2643] 49011. <br /> PANEL MANUFACTURER: 490-12. MODEL q: 490-I3. <br /> IN-TANK PROBE MANUFACTURER: 09014- MODEL 1)(S): 490-15. <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY 490-16. <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 490-17. <br /> 490 I8 <br /> PROGRAMMED TESTS ❑ a 0 1 g.p.h. ❑ b 0.2 g.p.h. ❑-c OTHER(Specify) 490 19 <br /> _...... .................. . .. ..._ .. - <br /> ❑ 3 MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR§2646.1) ago zo. <br /> ...._ _ ........___.__... __. . .._......... .. .__.-___... ..............__ ........._... __. .. <br /> ❑ 4 WEEKLY MANUAL TANK GAUGING(MTG)[23 CCR§26x5] TESTING PERIOD ❑ a 36 HOURS ❑ b 60 HOURS 490 z 1. <br /> ____._ .....____ ........ _.....__.,, . ... ....._.._........ ....___.. _- 490 22. ........ <br /> ❑ 5 TANK INTEGRITY TESTING PER[23 CCR 42643.17 490-23. <br /> 4 <br /> TEST FREQUENCY Ela El b 24. <br /> BIENNIALLY 0 c.OTHER(Specify): 490 2d25 <br /> ❑ 99.OTHER(Specify) 490-27 <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) ihi ak l) <br /> ® L CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT Wffl-1 AUDIBLE&VISUAL ALARMS. 99021. <br /> (23 CCR SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 400-29 <br /> §2616] <br /> PANEL MANUFACTURER:Veeder Root 490-30� MODEL#: TLS-350 490-31. <br /> LEAK SENSOR MANUFACTURER: Veeder Root 490-32_ MODEL N(S): 794380-323 490-33. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ® a.YES Elb.NO 490-34. <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 491-35. <br /> _.. __.. ____._.. .. --------------------------------------- .. .... <br /> ® 2 MECHANICAL LINE LEAK DETECTOR(MELD)THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS AND RESTRICTS OR SHUTS OFF 49036. <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.[23 CCR§26361 <br /> MELD MANUFACTURER(S):VMI 490-31. MODEL k(S): LD2000 490-38. <br /> ___.._ .... ............... .___-----------_.___...._............................... <br /> __ .__......_........ <br /> ❑ 3._..ELECTRONIC..__._..__ ... <br /> LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.[23 CCa§2636] 490-39. <br /> ELLD MANUFACTURER(S): 49640. MODEL N(S): 490-41. <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a.MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. 49042. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 49041- <br /> ELLD FAILUREIDISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO a9044. <br /> ........... ...... ... ... .......... ...................................--------.. ..... ..................... <br /> 4.PIPE INTEGRITY TESTING. 49045. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b EVERY 3 YEARS ❑ c 490-46 <br /> OTHER(Specify) 491-02- <br /> ❑ 5. VISUAL PIPE MONITORING. 490-48. <br /> FREQUENCY: ❑ a.DAILY ❑ b.WEEKLY ❑ C.MIN.MONTHLY&EACH TIME SYSTEM OPERATED' 49049. <br /> . ... .Alowdomoton.5 of unto n .emergeny... . fllxSC 2528L5bx)_ <br /> ... <br /> . ....___ ... _ <br /> ❑ 6 SUCTION PIPING MEETS EXEMPTION CRITERIA.[23 CCR§2616(a)(3)] 490 50 <br /> __________ .. ...... ..____.. __.._______ .......... ...._.______ ............ ... ........ <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20 CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 490 51 <br /> .__... .. ...._...... ................. _... ......._._ """ ... _..._..,......_ .................. .............. ..,.-.......- ....._ .. <br /> 490-52. <br /> ❑ 99.OTHER(Specify) 490-53. <br /> ............. .......:__r,_.:____-_._.o--.:--- ..__-i .....-o <br />
The URL can be used to link to this page
Your browser does not support the video tag.