My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2115
>
2300 - Underground Storage Tank Program
>
PR0526335
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 2:25:29 PM
Creation date
11/8/2018 10:03:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0526335
PE
2351
FACILITY_ID
FA0017819
FACILITY_NAME
7 ELEVEN 2369-39858A
STREET_NUMBER
2115
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
2115 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\Y\YOSEMITE\2115\PR0526335\COMPLIANCE INFO 2016 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
4/13/2017 6:43:54 PM
QuestysRecordID
3126416
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
261
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Date: <br />May 04, 2018 <br /> Facility Address: <br /> 2115 W YOSEMITE AVE, MANTECA <br /> Facility Name: <br /> 7 ELEVEN 2369-39858A <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually. <br />Annual monitoring system certification and leak detector testing were last performed on 03/29/2018 and was due <br />next calender year. Monitoring system certification testing is being performed on 05/04/18, and is two months past <br />due. These tests are required once every 12 months. Take all necessary precautions to ensure testing is <br />performed in a timely manner. <br />This is a repeat violation, Class II. <br /> 115 CCR 2715(a) Failed to submit to EHD notification of designated operator identification or change w/in 30 days. <br />A new designated operator was chosen since the last monitoring certification and notification was not provided to <br />the EHD within 30 days of the change. ECO-Check is the designated operator. The current Designated operator <br />form on CERS indicates Afforda-test as the DO Any changes shall be reported to the EHD within 30 days. <br />Immediately log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov and upload <br />the notification identifying all the designated operators for this facility. <br />This is a minor violation. <br /> 201 CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br />The facility, and the designated operator failed to check that alarms were responded to appropriately. The missing <br />alarms include an L23 Dispenser 1-2 brine alarm that occurred on the designated operator monthly inspection <br />reports dated: 2/15/18, 1/18/18, 12/21/17, 11/17/17, and 10/27/17. During the monthly inspection, the designated <br />operator shall review the alarm history for the previous month, check that each alarm was documented and <br />responded to appropriately, and attach a copy of the alarm history with documentation taken in response to any <br />alarms to the monthly report. Ensure that designated operators performing monthly inspections at this facility are <br />including all of the required information on the reports. <br />This is a minor violation. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to check and note the correct test dates for the last monitoring system certification <br />that occurred on 3/29/17 on the April 2017 through April 2018 designated operator monthly inspection reports. <br />During the monthly inspection, the designated operator shall check that all required testing and maintenance for the <br />UST system have been completed and document the dates they were done. Ensure that designated operators <br />performing monthly inspections at this facility are including all of the required information on the reports. <br />This is a minor violation. <br />Page 4 of 5 <br />FA0017819 PR0526335 SC001 05/04/2018 <br />EHD 23-01 Rev. 10/31/2017 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com
The URL can be used to link to this page
Your browser does not support the video tag.