My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1987 - 2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
244
>
2300 - Underground Storage Tank Program
>
PR0231137
>
COMPLIANCE INFO 1987 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 1:16:56 PM
Creation date
11/8/2018 10:22:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987 - 2007
RECORD_ID
PR0231137
PE
2361
FACILITY_ID
FA0001554
FACILITY_NAME
MIRACLE MILE MARKET
STREET_NUMBER
244
Direction
W
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13708014
CURRENT_STATUS
01
SITE_LOCATION
244 W HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\H\HARDING\244\PR0231137\COMPLIANCE INFO 1987 - 2007 .PDF
QuestysFileName
COMPLIANCE INFO 1987 - 2007
QuestysRecordDate
7/21/2016 3:39:19 PM
QuestysRecordID
3146929
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONI'V PRING SYSTEM CERTIF;�ATION <br /> ' For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared <br /> for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST sy&11ms widiut 30 <br /> days of test date. <br /> A. General Information <br /> Facility Name: ICd-S+ ar,e( tFasy MAit7- Bldg.No.: rn <br /> 1�^ <br /> Site Address: a44 NCr•d'vsc��t City: S+ockf-oA Zip�D� <br /> zi <br /> Facility Contact Person: Mf K z A L I Contact Phone No.: a1( Oy ) IF112 -899 <br /> _. <br /> Make/Model of Monitoring System: OminteC ZDEL 9000 Date of Testing/Servicing: S-A,-zZ 3rn^z <br /> p r <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific a ui ment inspected/serviced: <br /> Tank ID: ()A )-G 0.d{d , � Tank ID: r G wl t'J M <br /> / [.t, <br /> In-Tank Gauging Probe. Model: r IT67 'F 2rin-Tank Gauging Probe. Model: M T-(rt-r <br /> (-'Anular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model:Rii,- t-W F <br /> (�iping Sump/Trench Sensor(s). Model: X-L� $Piping Sump/Trench Sensor(s). Model: RX-L 5—Ai. <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: L"echanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> O Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specia a ui ment type and model in Section E on Pae 2). ❑ Other(specia equipment t e and model in Section E on Pae 2), <br /> Tank ID: Tan <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-Tank Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space or It Sensor. Model: <br /> ❑ Piping Sump/Trench Sensor(s). el: ❑ Piping Sump/Trench�S2nspr(s). Model: <br /> • Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). � Model: <br /> ❑ Mechanical Line Le ector. Model: ❑ Mechanical Line Leak Detector. Model <br /> ❑ Electronic Li ak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> 13 Tan ill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ME er(s eci a ui mine <br /> t e and model in Section E on Page 2). ❑ Other(specia a ui ment a and model in Section E on Page 2 .� <br /> Dispenser ID: Z Dispenser ID: -3 <br /> ( )Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> hear Valve(s). .9'�hear Valve(s). <br /> ,,�/Di5 enser Containment Float(s)and Chains . $Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: user ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Disp Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve <br /> LDispenser <br /> is enser Containment Floats and m s). ❑ Dispenser Containm loat(s)and Chain (s). <br /> ID: Dispenser ID: <br /> Dispenser Con inm nt Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Modekhe e(s). ❑ Shear Valve(s). <br /> �s enser Containment Float(s)and Chain (s). ❑ Dis enser Containment Floats and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipme t capable of generating such reports,1 have also <br /> attached a copy of the report; (check all that apply): ( )System set-up ( Alarm history report <br /> Technician Name(print): LEE A. WILLIAMS Signature: , <br /> Certification No.: S� I t7d- b y e 1 License.No.: 03160 <br /> Testing Company Name: Stockton Service Station Eauioment Co.,Inc. Phone No.:(209)464-8333 <br /> Site Address: JUIN k4rrJ rt,= tai q Date of Testing/Servicing: SV/GLC, 3 <br /> Page 1 of 0310I <br /> Monitoring System Certification <br />