My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1998
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
15600
>
2300 - Underground Storage Tank Program
>
PR0231585
>
INSTALL_1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2021 11:18:19 AM
Creation date
11/8/2018 10:22:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1998
RECORD_ID
PR0231585
PE
2361
FACILITY_ID
FA0000174
FACILITY_NAME
JOES TRAVEL PLAZA
STREET_NUMBER
15600
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19620079
CURRENT_STATUS
01
SITE_LOCATION
15600 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\H\HARLAN\15600\PR0231585\INSTALL 1998.PDF
QuestysFileName
INSTALL 1998
QuestysRecordDate
12/20/2017 9:22:38 PM
QuestysRecordID
3752004
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
240
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ D. Alternate construction for new underground storage tanks containing motor vehicles fuel [Section 26331. <br /> (1) Monitoring and response plan [Section 26342. <br /> (2) Underground storage tank composed of.... <br /> (a) Fiberglass reinforced plastic. <br /> _ (b) Cathodically protected steel. <br /> (c) Steel clad with fiberglass reinforced plastic. <br /> _ (d) Other material that complies with section 2631 and 2632. <br /> --�—(3) Floor of leak interception and detection system constructed on a firm base and sloped to a <br /> collection sump (use of membrane Liners comply with section 2631 (d) (6) requirements.) <br /> �- (4) Access casings installed in the collection sump of the secondary containment system with <br /> backfill in the interstitial space. The access casing shall meet all of the following: <br /> _ Designed and installed to allow the liquid to flow into the casing. <br /> _ Sized to allow removal of collected liquid and able to withstand all anticipated applied <br /> stresses. <br /> _ Constructed of material that will not be structurally weakened. <br /> _ Screened along entire vertical zone of permeable material. <br /> _ Capable of preventing leakage of any hazardous substance from the casing. <br /> Extend to the ground surface and covered with a Locked waterproof cap. <br /> _ Capable of meeting S.J. Co. PHS-EHD well Standards. <br /> _ Leak interception and detection system shall prevent the Leaked hazardous substance from <br /> entering ground water. <br /> 14. INTERSTITIAL SPACE MONITORING <br /> A. Visual monitoring [Section 2632 (c) (1)] <br /> (a) Exterior surface and floor beneath tank monitored by direct viewing <br /> _ (b) Daily visual inspections <br /> _ (c) Liquid Level in tank to be recorded at time of inspection <br /> _ (d) If Liquid observed around or beneath primary tank, owner will determine if an unauthorized release <br /> has occurred. <br /> 8. Mechanical or electronic monitoring (Section 2632 (c) (2)1 <br /> �- (a) Continuous monitoring system connected to an audible and visual alarm system. <br /> Monitoring equipment to be installed p � L /� <br /> Manufacturer: ��P-2cllR.R- 1`s'v`I ©4� • f� <br /> _ Model Number: <br /> Sensor Type: Vapor Liquid _ Both. <br /> Sensor/Panel specifications. <br /> _ Location(s) for sensors: <br /> Tank: PIC Piping: <br /> Dispenser: <br /> C. Monitoring and response plan submitted [Section 2632 (d) (1) & (2)]. <br /> t <br /> 15. Any special accessories, fittings, coatings, or linings not inherent within the initial design of the 10 tank or <br /> double-wall UST. [Section 2631 (b)] <br /> A. Approved by a nationally recognized independent testing organization. <br /> B. Demonstration of integrity with the primary and/or secondary containment. <br /> 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.