COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
23500
>
2300 - Underground Storage Tank Program
>
PR0231636
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2021 1:16:42 PM
Creation date
11/8/2018 10:22:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231636
PE
2381
FACILITY_ID
FA0003869
FACILITY_NAME
DEUEL VOCATIONAL INSTITUTION*
STREET_NUMBER
23500
STREET_NAME
KASSON
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
23912001
CURRENT_STATUS
02
SITE_LOCATION
23500 KASSON RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\K\KASSON\23500\PR0231636\COMPLIANCE INFO 1986 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 1986 - 2015
QuestysRecordDate
10/10/2017 4:11:16 PM
QuestysRecordID
175458
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
216
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING ALTERNATIVE 6 <br />Implementation of this monitoring alternative will require <br />Daily Inventory Reconciliation, Annual Tank Integrity <br />Testing, Pipeline Leak Detection, Vadose Zone or Ground Water <br />Monitoring Wells, and Soil Testing. If this monitoring <br />alternative is chosen, implementation should be carried out <br />as follows: <br />1) Perform the initial tank integrity test/tests to confirm that <br />the tank/tanks do/does not leak at the time of implementation <br />of the monitoring alternative. Integrity testing must be <br />done within one year prior to implementation of the <br />monitoring alternative. Based on information obtained from <br />facility personnel all/the tanks/tank at this facility have <br />passed an integrity test within the last year. <br />Vadose Zone Wells <br />2a) Undisturbed soil samples shall be taken from the soil <br />immediately surrounding each/the tank. The boring/borings <br />shall be drilled to a depth of 40 feet and undisturbed soil <br />samples shall be taken at 5 foot intervals with the last <br />sample obtained from the base of the borings. All samples <br />shall be properly sealed, labeled and preserved until they <br />are delivered to a location where they can be analyzed to <br />determine the presence of any possible hazardous substances <br />that are present. Soil sampling and testing shall be carried <br />out as specified in Section 2645 of the Underground Storage <br />Tank Regulations. <br />3a) If the soil samples obtained are determined to be free of <br />hazardous material a vadose zone monitoring well shall be <br />installed in the vacated boring/borings. Vadose zone <br />monitoring wells shall be designed and installed as specified <br />in Sections 2646 and 2648 of the Underground Storage Tank <br />Regulations. Vadose zone testing shall be performed <br />semi-annually, at a minimum. Three types of vadose zone leak <br />detectors, each of which would be acceptable for use at this <br />site are attached at the end of the package. <br />4a) Implementation of this monitoring alternative will require <br />annual calibration of flow meters by the State of California <br />Bureau of Weights and Measures. <br />