COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
23500
>
2300 - Underground Storage Tank Program
>
PR0231636
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2021 1:16:42 PM
Creation date
11/8/2018 10:22:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231636
PE
2381
FACILITY_ID
FA0003869
FACILITY_NAME
DEUEL VOCATIONAL INSTITUTION*
STREET_NUMBER
23500
STREET_NAME
KASSON
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
23912001
CURRENT_STATUS
02
SITE_LOCATION
23500 KASSON RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\K\KASSON\23500\PR0231636\COMPLIANCE INFO 1986 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 1986 - 2015
QuestysRecordDate
10/10/2017 4:11:16 PM
QuestysRecordID
175458
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
216
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Results of '.S. EPA Standard Evaluatior <br />Automatic Tank Gauging System (A?GS) <br />lhis form tells whether the automatic tank gauging system (ATGS) described below complies with <br />the performance requirements of the federal underground storage tank regulation. The evaluation <br />was conducted by the equipment manufacturer or a consultant to the manufacturer according to <br />the U.S. EPA's "Standard Test Procedure for Evaluating Leak Detection Methods: Automatic <br />Tank Gauging Systems." The full evaluation report also includes a form describing the method and <br />a form summarizing the test data. <br />Tank owners using this leak detection system should keep this form on file to prove compliance <br />with the federal regulations. Tank owners should check with State and local agencies to make sure <br />this form satisfies their requirements. <br />ATGS Description <br />Name EASI Level -Tru <br />Version number <br />Vendor <br />721 Charcot Avenue <br />street a dress qoe <br />San Jose, CA 95131 (JdM) 954-9081 <br />M,,, 7io (0hone) <br />Evaluation Results <br />This ATGS, which declares a tank to be leaking when the measured leak rate exceeds the <br />threshold of 0.1gallon per hour, has a probability of false alarms [P(FA)] of 4. 6 %. <br />The corresponding probability of detection [P(D)] of a 0.20 gallon per hour leak is 95. 4 %. <br />The minimum water level (threshold) in the tank that the ATGS can detect is 0.896 inches. <br />The minimum change in water level that can be detected by the ATGS is <br />(provided that the water level is above the threshold). <br />Therefore, this ATGS 0 does ❑ does not meet the federal performance standards <br />established by the U.S. Environmental Protection Agency (0.20 gallon per hour at P(D) of 95% <br />and P(FA) of 5%), and this ATGS El does ❑ does not meet the federal performance <br />standard of measuring water in the bottom of the tank to the nearest 1/8 inch. <br />023 inches <br />Test Conditions During Evaluation <br />The evaluation testing was conducted in a 10.000 gallon L111 steel ❑ fiberglass tank that <br />was 96 inches in diameter and 324 inches long. <br />The temperature difference between product added to fill the tank and product already in the <br />tank ranged from -5.7 °F to 6.1 OF, with a standard deviation of 4.5 F. <br />The tests were conducted with the tank product levels 50 and 90-95 % full. <br />The product used in the evaluation was diesel fuel <br />ATGS - Results Form <br />_- -- -1 lowac, itmdly notify of at once. <br />,re not „ noted, kindly notify w ,t onc.. <br />11 enclo,mv err not .. -m.n <br />Page 1 of 2 <br />