My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
1111
>
2300 - Underground Storage Tank Program
>
PR0506724
>
COMPLIANCE INFO 2008 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 10:12:19 AM
Creation date
11/8/2018 10:22:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2015
RECORD_ID
PR0506724
PE
2361
FACILITY_ID
FA0007594
FACILITY_NAME
WINE COUNTRY STATION/7-ELEVEN
STREET_NUMBER
1111
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04931056
CURRENT_STATUS
01
SITE_LOCATION
1111 E KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\K\KETTLEMAN\1111\PR0506724\COMPLIANCE INFO 2008 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2008 - 2015
QuestysRecordDate
6/27/2018 4:14:35 PM
QuestysRecordID
3926585
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
368
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• SAN JOAQUIN COUNTY • <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.swaov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility address: Inspection Date: <br /> Wine Country Station/7-Eleven 1111 E. Kettleman Ln. Lodi, CA 95240 October 6, 2010 <br /> # Code Section VIOLATIONS V R <br /> HSC=CA Health&Safety Code;CCR=CA Code of Regulations;V=Violation; Repeat Violation V <br /> Designated operator monthly inspection:(cx1)alarms not documented;(c)(2-4)spill containers, <br /> 23c CCR 2715(c),(e) UDCs,and sumps(if necessary)not inspected;(cx5)required test dates not checked or noted;(c)(6) X <br /> employee training not verified; (e)monthly inspection reports not maintained on site for at least 12 <br /> months <br /> 23d CCR 2715(f) Designated operator employee training:(1)not performed; (2)not current for at least one employee <br /> on site 3 log not kept <br /> Monitoring equipment certification: (a)not performed annually;(d)test report not submitted within 30 <br /> 24 CCR 2638 days;(e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, <br /> repair, replacement,calibration,or Certification;(f)performed,and failed to affix a tag/sticker on each <br /> monitoring equipment corn onent that was certified repaired, or relaced <br /> 25 NSC 25291 Annual line leak detector test not performed 1Mt <br /> 26 HSC 25284.2 Annuals ill containment testing not performed <br /> 27 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (MI) <br /> 28 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to permit (M2) <br /> conditions <br /> 29 CCR 2643(e) Biennial tightness test of gravity pipingnot performed(pre-January 1, 1984 (Mf) <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed re-Janus 1, 1984 Mt <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and <br /> retested <br /> 32 CCR 2661 Permit toreair UST system not obtained <br /> 33 HSC 25286(a) rational permit not amended when UST storage and/or monitoring system changed <br /> 34 HSC 25298(b) Permit to temporarily dose UST system not obtained <br /> 35 HSC 25298(c) Permit to dose UST system not obtained <br /> 36 HSC 25299(0(2) Tampering with or disabling leak detection devices or alarms <br /> 37 HSC 25298(a) Illegally abandoned UST s stem <br /> 38 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not keDt <br /> 39 CCR 2631.1 a UST system is not compatible with the substance stored <br /> Emergency generator systems <br /> 40 CCR 2636 6 Eme en enerator monitoringsystem not checked dailyor I not keptif no leak defector <br /> 41 HSC 25281.5 b 3 Unburied fuel i in not visual) inspected at least month) or I not kept (M1 <br /> AB 1702(2003-2004) HSC 25290.2(installed between 07/01/03 and 05130/04) <br /> VPH Systems HSC 25290.1 installed on or after 07/01/04 <br /> Compatibility and permeability requirements:(a)UST system is not compatible with the substance <br /> 42 CCR 2631.1 stored;(b)results of the compatibility and permeability testing requirements listed in subsections CCR <br /> 2631 b and d for a UST system installed after July 1,2004,were not submitted <br /> 43 HSC 25290.2 SC 25290.1(c)(1) <br /> Hc1 Primary containment not liquid or vapor tight <br /> 44 HSC 25290.1(0)(2) Secondary containment not liquid or vapor tight <br /> HSC 25290.2 c 2 <br /> 45 HSC25290.1(0)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c)'3) <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or ill <br /> HSC 25290.2 d the entry of liquid or vapor from the primary containment into the secondary containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum, or constant pressure in the interstitial (1111) <br /> space of the UST system not maintained <br /> HSC 25290.1() UST system not tested by one of the following methods prior to use:(1)Enhanced leak detection;(2) <br /> 48 HSC 25290.2(1) inert gas pressure test approved by SWRCB; (3)test method deemed equivalent to(1)or(2)by the <br /> SWRCB <br /> Other violations <br /> 999 1 Other. See attached"continuation-official Inspection Report"for violation(s)not listed above. <br /> EHD inspect 7N SAI� S UIC <br /> SOotic system: <br /> Serves>20 people/day <br /> Received by: Tine: ❑Receives other than sanitary waste <br /> Other disposal methods: <br /> - El Dry wells/French Drains <br /> EHO 23-02-002 REV 08/13/10 Page 2 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.