My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
13975
>
2300 - Underground Storage Tank Program
>
PR0231622
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:27 AM
Creation date
11/8/2018 10:26:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231622
PE
2351
FACILITY_ID
FA0000055
FACILITY_NAME
TESORO (SHELL) 68150 (WRR 6133)
STREET_NUMBER
13975
Direction
E
STREET_NAME
STATE ROUTE 88
City
LOCKEFORD
Zip
95237
APN
01908014
CURRENT_STATUS
01
SITE_LOCATION
13975 E HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\E\HWY 88\13975\PR0231622\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
6/2/2014 6:52:07 PM
QuestysRecordID
90861
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
144
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN- Pae 1 of 2 <br /> TYPF.OF ACTION ❑ I.NEW PLAN X 2.CHANGE OF INFORMATION 4va.1 <br /> PLAN TYPE X 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 4v 2 <br /> /Check one item aniy) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> I. FACILITY INFORMATION <br /> FACILITY ID q(.4gerny Lire On7)/ <br /> _ _ I <br /> BUSINESS NAME(Some as Facility;Vome or DBA) <br /> USAITesoro 88150 <br /> BUSINESS SITE ADDRESS 13975 E. Highway 88 101 CITY <br /> Lockeford Ia <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenmum mid calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)most be performed a the frequency specified <br /> by the equipment manufacturer ins"etions,or annually,whichever is more frequent.Suc_h work most be performed by qualifiedQersonrml.Iv cta gz63z,m>.,zess_.:wi I <br /> -_____ <br /> _ .__ -_ - _ <br /> MONITORING EQUIPMENT IS SERVICED x 1.ANNUALLY ❑ 99.OTHER S ci 490.1` <br /> III. MONITORING LOCATIONS <br /> ❑ 1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN X 2.SITE PLOT PLAN/MAY PREVIOUSLY SUBMITTED R3 CCR 1263;36341 600'+ <br /> IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) that <br /> "`�wf <br /> X L CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT vAULT(S) +vOJ <br /> W ITH AUDIBLE AND VISUAL ALARMS.(v Cat§2632,2634) <br /> SECONDARY CONTAINMENT IS: X R DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d. UNDER VACUUM 49 <br /> PANEL MANUFACTURER: Gilbarco 400.7 MODEL#- EMC a9°' <br /> LEAK SENSOR MANUFACTURER: Veeder Root 690'9 MODEL#(S): 794390-420 60°10 <br /> rr 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINQLE WALL TANKlcJ.fv cca pz6OI [vo:i i <br /> PANEL MANUFACTURER: 4valz. MODEL#: 690 13 <br /> IN-TANK PROBE MANUFACTURER: 6°0'1i MODEL#(S): 490.11 <br /> 1 LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ K DAILY/NIGHTLY ❑ c.WEEKLY +9p'16 <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 490-13 <br /> _-PROGRAMMED TESTS_ ❑ a0.lg_p_h_ ❑ b.0.2 h. ❑ c.OTHERS wale <br /> ❑ 1.MONTHLY STATISTICAL INVENTORY RECONCILIATION Iv CCR}.646 it av0.zo <br /> _.__ __. _-.. _ __ <br /> 4 WEEKLY MANUAL TANK GAUGING(INTO)In ccR 4w4sl TESTING PERIOD <br /> ❑ a.36 HOURS ❑ b.60 HOURS 990.31 <br /> - .__-.- avo-v. <br /> 5. AN fMEGRfTY TESTING PER[v CCR yzbn.11 46ov <br /> TEST FREQUENCY: ❑ a ANNUALLY - ❑ b.BIENNIALLY ❑ c.OTHER(Specify): 490.90'34 <br /> - _ 's__.- <br /> X 99.OTHER(Specify): Tanks are monitored b Sacrificial Anodes. <br /> Evan. <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) <br /> X I.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CO <br /> Iv CCR NTAINMENT WITH AUDIBLE&VISUAL ALARMS. d°028 <br /> SECONDARY CONTAINMENT IS: X a DRY ❑ d.UNDER VACUUM <br /> g26n1 ❑ b.LIQUID FILLED ❑ c.PRESSURIZED 49429 <br /> PANEL MANUFACTURER:Gilbarco 400.30. MODEL#: EMC 49411 <br /> LEAK SENSOR MANUFACTURER: Veeder Root i90'12 MODEL#(S): 794380-208 69 13 <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. X a YES ❑ b.NO 490-4 <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. X a YES ❑ b.NO 'w-1: <br /> X 2. MECHANICAL LLNE LEAK DETECTOR(MELD)THAT ROUTINELY PERFORMS J.0 g.p.h. LEAK TESTS AND RESTRICTS OR SHUTS OFF +9436. <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.Iv CCRJ26361 <br /> MLLD MANUFACTURER(S):Vaporless40037 MODEL#(S): LD2000 4s 33. <br /> ❑ 3.ELECTRONIC LME LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS[v ccRgzbJbl as0.1v <br /> ELLD MANUFACTURER(S): 690'0 MODEL#(S): <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a.MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. 490.ip <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a YES ❑ b.NO 490-13 <br /> ELLD FAILUREIDISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a YES ❑ b.NO 490.46 <br /> S-PIPE INTEGRITY TESTING. - - - - _-- - -- - avori <br /> TEST FREQUENCY ❑ a ANNUALLY_ ❑ b.EVERY 3 YEARS ❑ c.O"IHER(S cify) 69049°!'46 <br /> Ej 5.VISUAL PIPE MONITORING. - -oaa. <br /> FREQUENCY: ❑ eDAILY ❑ b.WEEKLY ❑ C.MIN.MONTHLY&.EACH TIME SYSTEM OPERATED' <br /> ._ -.. PIP <br /> ❑ 6 SUCTIONONPIPING MEETS EXEMPTION CRITERIA.(n CCR q263q.µ1)I 4vo.16. <br /> [I 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. <br /> 99.OTHER(Specify) - - - -� 6vasi <br /> i90.5J <br /> 11PCF UST-D(122007)-1/S www.unidoes.org <br />
The URL can be used to link to this page