Laserfiche WebLink
1868 <br />Telephone: <br />San Joaquin County <br />Environmental Health Department <br />East Hazelton Avenue, Stockton, California 95205-6232 <br />(209) 468-3420 Fax: (209) 468-3433 Web: www.sjaov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />SUPER CENTER MART` <br />Facility Address: <br />701 E DR MARTIN LUTHER KING JR BLVD, <br />Date: <br />June 19, 2014 <br />On Site Records <br />205 <br />HSC 25294, 25295 <br />Failed to record or report unauthorized release in appropriate time frame <br />■ V ❑ R ❑ COS <br />206 <br />CCR 2715 <br />Designated operator did not inspect all required items and/or the inspection reports not completed <br />❑ V ❑ R ❑ COS <br />207 <br />CCR 2715 <br />Designated operator monthly inspection reports not maintained on site for at least 12 months <br />❑ V ❑ R ❑ COS <br />208 <br />CCR 2715(f) <br />Designated operator employee training not performed or log not kept <br />■ V ■ R ❑ COS <br />209 <br />CCR 2715(f)(2) <br />Unstaffed facility failed to have or implement a training program approved by the EHD <br />❑ V ❑ R ❑ COS <br />210 <br />HSC 25281.5(b)(2) <br />Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br />❑ V ❑ R ❑ COS <br />211 <br />HSC 25281.5(b)(3) <br />Unburied emergency generator fuel piping not visually inspected at least monthly or log kept <br />❑ V ❑ R ❑ COS <br />UST System Observations <br />301 <br />HSC 25291.1 <br />UST system is not operated to prevent unauthorized release, including spills and overfills <br />❑ V ❑ R ❑ COS <br />302 <br />HSC 25291(b) <br />UST system incapable of detecting leak from primary into secondary containment (pre -Jul 2003) <br />❑ V ❑ R ❑ COS <br />303 <br />HSC 25290.2(d) <br />Monitoring system not maintained to detect entry into secondary containment (Jul 2003 -Jun 2004) <br />❑ V ❑ R ❑ COS <br />304 <br />HSC 25290.1(d) <br />Monitoring system not maintained to detect entry into secondary containment (after Jul 2004) <br />❑ V ❑ R ❑ COS <br />305 <br />HSC 25290.1(e) <br />VPH monitoring of the interstitial spaces of the UST system is not maintained <br />❑ V ❑ R ❑ COS <br />306 <br />CCR 2630(d) <br />Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity <br />■ V ❑ R ■ COS <br />307 <br />CCR 2632(c) <br />Monitoring system of the interstitial space of a double walled system not maintained <br />❑ V ❑ R ❑ COS <br />308 <br />CCR 2636(f) <br />Failed to maintain a continuous monitoring system that activates an audible and visual alarm <br />❑ V ❑ R ❑ COS <br />309 <br />CCR 2636(f)(1) <br />Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC <br />❑ V ❑ R ❑ COS <br />310 <br />CCR 2636(f)(1) <br />Sensor in a piping sump failed to activate an audible and visual alarm or stop the flow product <br />❑ V ❑ R ❑ COS <br />311 <br />CCR 2636(f)(5) <br />Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs <br />❑ V ❑ R ❑ COS <br />312 <br />CCR 2636 <br />Failed to properly program or operate leak detection equipment <br />❑ V ❑ R ❑ COS <br />313 <br />CCR 2638(f) <br />Failed to affix a tag sticker on monitoring equipment certified, repaired, or replaced <br />❑ V ❑ R ❑ COS <br />314 <br />CCR 2631(a) <br />Primary containment not tight (pre -Jul 2003) <br />■ V ❑ R ❑ COS <br />315 <br />HSC 25290. 1 (c)(1), <br />25290.2(c) <br />Primary containment not tight (after Jul 2003) <br />❑ V ❑ R ❑ COS <br />316 <br />HSC 25290.1, 25290.2, <br />25291 <br />Secondary containment not tight <br />❑ V ❑ R ❑ COS <br />317 <br />CCR 2636(a) <br />Failed to have secondary containment <br />❑ V ❑ R ❑ COS <br />318 <br />HSC 25290.1, 25290.2, <br />25291 <br />Failed to maintain all sumps (including UDCs) free of debris and liquid <br />❑ V ❑ R ❑ COS <br />319 <br />CCR 2636(c)(1) <br />All releases in secondary piping do not flow to a collection sump <br />■ V ❑ R ■ COS <br />320 <br />CCR 2636(f)(2) <br />Line leak detector not installed <br />❑ V ❑ R ❑ COS <br />321 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />■ V ■ R ■ COS <br />322 <br />CCR 2635(b) <br />No spill bucket installed or failed to provide a means to keep it empty <br />❑ V ❑ R ❑ COS <br />323 <br />CCR 2635(b) <br />Spill container failed to contain a minimum capacity of five gallons <br />❑ V ❑ R ❑ COS <br />324 <br />CCR 2635(b)(2) <br />Overfill prevention system was overridden or failed to meet overfill requirements <br />❑ V ❑ R ❑ COS <br />325 <br />HSC 25283.5 <br />Unburied below grade UST failed to meet exemption status <br />❑ V ❑ R ❑ COS <br />eceive I by (initial):Inspector: <br />STACY RIVERA, Senior REHS <br />Phone: <br />(209) 468-3440 <br />ate: <br />06/19/2014 <br />Page 2 of 5 <br />