1868 <br />Telephone: <br />San Joaquin County <br />Environmental Health Department <br />East Hazelton Avenue, Stockton, California 95205-6232 <br />(209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />SUPER CENTER MART <br />1701 E DR MARTIN LUTHER KING JR BLVD, <br />June 19, 2014 <br />UST System Observations <br />326 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R ❑ COS <br />327 <br />CCR 2717.1(0 <br />Deposited petroleum into a red tagged UST <br />❑ V ❑ R ❑ COS <br />328 <br />HSC 25299(f)(2) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V ❑ R ❑ COS <br />329 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />o V ❑ R ❑ COS <br />330 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R ❑ COS <br />331 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />❑ V ❑ R ❑ COS <br />Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R ❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />❑ V ❑ R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R r_ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V ❑ R ❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V ❑ R ❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />104 <br />UST Operating Permit Application for Facility and Tank information not submitted or current. UST Tank Information <br />forms for the 87 and 91 tanks are not current in CERS. Any change of information must be updated in CERS within 30 <br />days of the changes. Immediately log into CERS, update the required information, and submit for review by the EHD. <br />Complete a separate tank form for each tank. This is a repeat violation, Class II. <br />106 <br />Monitoring and response plans not current or approved by the EHD. The monitoring and response plans are not current <br />and/or not approved by the EHD. The monitoring plans submitted are incomplete; the portions that are filled in are <br />inaccurate. The response plan submitted is incomplete. The monitoring and response plans must be uploaded to the <br />California Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, and <br />submit for review by the EHD. Maintain an approved copy on site. This is a repeat violation, Class II. <br />107 <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed. An accurate UST <br />Monitoring Site Plan was not submitted. A site plan must be submitted identifying the locations where monitoring will be <br />performed. Immediately submit an accurate copy of the UST Monitoring Site Plan to the EHD for approval. <br />Alternatively, log into CERS, upload the completed form, and submit for review by the EHD. Maintain an approved copy <br />on site. This is a minor violation. <br />111 <br />Failed to test monitoring and leak detection equipment annually. Annual monitoring system certification, leak detector <br />testing, and spill container testing was scheduled to be performed on June 18, 2014 and a test report was submitted to <br />the EHD on August 23, 2013, more than 30 days later. A copy of the test report must be submitted within 30 days of <br />these tests. Ensure that all test reports are submitted within the required time frames. This is a repeat violation, Class <br />ll. <br />122 <br />Permit to repair UST system not obtained. The 87 STP relay was replaced on March 7, 2014 and a permit was not <br />obtained from the EHD. Emergency repairs relating to UST system monitoring and release detection may be performed <br />by a properly licensed, trained, and certified contractor pursuant to the EHD'S policy and a permit obtained within one <br />business day from the EHD. All other repairs must have a permit submitted to and approved by the EHD prior to <br />beginning work. Immediately obtain a permit from the EHD for the relay replacement. A "Failure to Obtain a Permit" <br />penalty applies. This is a Class II violation. <br />Received by initisInspector: <br />one: <br />ate: <br />STACY RIVERA, Senior REHS <br />(209) 468-3440 <br />06/19/2014 <br />Page 3 of 5 <br />