Laserfiche WebLink
Fm:KPH Io:tW: can you please tax MUMM3) <br />19:01 10/0y/lb H F9 7-11 <br />ion <br />P.O. Box 1289....... Waterford, CA 95386 Telephone: (209) 969-0851 i <br />Email: spccorp,(u,hotmail.co>_n ri E j E l y a <br />Website: www.spcplan.com <br />Certified Assessment Form (PE) for AST Systems OCT 05 <br />Assessor: Spill Prevention Compliance Corporation Onsite Assessor: Todd McWhorter <br />P.O. Box 1289 Telephone: (209) 969-0851 rNVIRONMENTAL <br />Waterford, CA 95386 email: spccorp i�hotmail.comy„a` rEpARTMEAIT <br />Client: Stockton Hyundai Contact Person: Andy McCue, Service Manager <br />Address: 2979 Auto Center Cir. 2nd Contact: <br />City/State/Zip: Stockton,, CA 95212 Date of Test: 9-22-1.5 <br />Assessment Data- Waste Oil AST —a <br />1. AST Configuration & age of AST Horizontal AST Single wall steel/approx. 15 yrs. old ( estimate ) <br />Ia. Useful Life Remaining of AST Approximately 15 years of remaining life (Subsection k1410) <br />2. AST Primary vessel construction (describe) 570 gals/Waste Oil/IJ” 402905 XL142-Container/ Made to UL. <br />142 construction standard -at least .123in. steel thickness per UL Std. - <br />3, AST piping (describe) 1 in, galvanized and painted piping from Graco Husky 1040 Pump to 2 in opening <br />w/fitting, from pump for supply to tots of AST. <br />4. Internal/Lxtemal pump description external Graco Hus!q 1040 primp w/2 solenoid 12volt-10-20012si-- <br />External numn, which numps waste oil from service areas (see pic)--_--_--_--- <br />5. ASI'drawing (provided/drawn: source) (see attached} <br />6. Design Standard (ASME, UL, etc_) UL 142 -Cylindrical Single Wall Steel /Mfr: ACE Tank <br />7. AST foundation (describe) concrete berm sub -floor, Base of AST under UL 142 adequate to withstand the <br />load of a full tank -Tank is anchored to floor <br />8. AST anchoring (seismic zone/floatation risk) AST is anchored to the floor slab with 3/8 in, diameter <br />expansion anchors into the concrete berm floor. Stockton is in a round-shaking)seismic rtgjon., but the AST <br />is unlikely to move outside the room in an event, nor pose a risk of flotation in such an event. The AST is <br />situated in secured lubricants room. <br />9. AS 1' will withstand frost -heave XX Yes No AST sits in concrete cinder block berm <br />10. AST previously relocated? Ycs XX No <br />11. AST Corrosion Protection Tank is completely covered in paint, without evidence of corrosion. Tank has <br />no specific corrosion protection beyond the paint No part of the AST touches the ground. The base of the <br />AST is steel raising the AST 1 inch above the floor. There is no evidence of corrosion taking place, however <br />there is debris beneath AST which should be removed. Tank's construction material is carbon steel. <br />1.2. AST Spill Prevention l quipmcnt AST has product is placed into AST via pumping from external Graco <br />Husky Pump Product generally not handled outside of its intended containers. Product removal occurs via <br />pumping out thru a 2 plugged opening in top of AST <br />13. Overfill Protection: AST sits in concrete berm with a Sentry product level alarm in the berm. This alarm <br />was tested and found to be operating. The sound was minimal and indicative that the ba eries in the flat°ttt <br />should be changed. AST has Krueger level gauge to indicate product levels in AST. <br />