My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006 - 2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAM
>
1331
>
2300 - Underground Storage Tank Program
>
PR0231332
>
COMPLIANCE INFO 2006 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2019 4:07:20 PM
Creation date
12/5/2018 9:18:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2010
RECORD_ID
PR0231332
PE
2361
FACILITY_ID
FA0003961
FACILITY_NAME
LODI MUNI SERVICE CENTER
STREET_NUMBER
1331
Direction
S
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95240
APN
03104050
CURRENT_STATUS
01
SITE_LOCATION
1331 S HAM LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SE-P-10-2009 17:01 CITY OF LODI 209 333 6710 P.09 <br /> Underground Storage Tank Monitoring a--)Page 2 of 2 <br /> VI. DISPENSER MONITORING <br /> MONITORING OF AREAS SENEATH DISPENSER(S)IS PERFORMED USING THE FOLLOWING METHOD(S)(Check all that apply) Wo. <br /> ® 1.CONTINUOUS ELECTRONIC MONITORING OF UNDER DISPENSER CONTAINMENT(UDC) <br /> PANEL MANUFACTURER;Veeder-Root _ M51. MODEL#.TLS 350 _ MS2. <br /> LEAK SENSOR MANUFACTURER; - `f53 MODEL#(S):OZ94380-208 M54 <br /> WILL DETECTION OF A LEAK INTO THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? ® a.YES ❑ b.NO MSS, <br /> WILL A UDC;LEAK ALARM TRIGGFR AUTOMATIC PUMP SHUTDOWN? E a,YES Ij b.NO M'6. <br /> WII,L FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? ® a YES ❑ b,NO Msz <br /> ❑ 2.MECHANICAL ASSEMBLY(e.g.,FLOAT AND CHAIN ASSEMBLY)IN UDC TRIPS.SHEAR VALVE IN CASE OF LEAK <br /> Msa <br /> ASSEMBLY MANUFACTURER: M58. MODEL#(S): <br /> ❑ 3.VISUAL MONITORING DONE: ❑ a.DAILY ❑ h.WEEKLY("ulros R8my aPPrwal) Meo <br /> Q 4,NO DISPENSERS <br /> Mbt <br /> ® 99.OTHER(Specify) Monthly Visual Ins ection <br /> VII. ENHANCED LEAK DETECTION <br /> ❑ I,WE HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED Ll?AK Mlo. <br /> DETECTION(ELD)FOR THE UST(S)COVERED BY THIS PLAN•PFR 23 CCR§2644.1,LLD IS PERFORMED EVERY 36 MONTHS AS REQUIRED <br /> VIII. TRAINING <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) Mao. <br /> I. ® THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) <br /> 2. 0 OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required) <br /> 3• ® THE FACILITY'S 13PST MANAGEMENT-PRACTICES(Required as or,)anuary 1,2005) <br /> 4. ® CALIFORNIA UNDERGROUND STORAGE TANK REGUI,ATIONS <br /> 5. ® CALIFORNIA UNDERGROUND STORAGE TANK LAW <br /> 6, ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL, AND <br /> S'T'ATISTICAL INVENTORY RECONCILIATION" <br /> 7. ❑ SWRCB PUBLICATION:"WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS" <br /> ME]. <br /> 99. ❑ OTHER(Specify): <br /> Personnel with UST monitoring responsibilities are familiar with all of the above documents relevant to their job duties and can access those documents when needed. <br /> 0y January 1,2005,this facility will have a"Designated UST Operator"who has passed the Califomia(IST Sytem Operator Exam administered by the International <br /> Code Council(ICC). By July 1,2005,and annually thereafter,the "Designated UST Operator"will train facility employees in the proper operation and maintenance <br /> of the US'r systems.This training will include,but is not limited to,the following: <br /> ➢ Operation of the UST systems in a manner consistent with the facility's best management practices. <br /> Y The facility employee's role with regard to the leak detection equipment. <br /> The facility employee's role with regard to spills and overfills. <br /> ➢ Whom to contact for emergencies and leak detection alarms. <br /> For facility employees hired on or after July 1,2005,the initial training will be conducted within 30 days of the date of hire, <br /> IX. COMMENTS/ADDITIONAL INFORMATION <br /> Please use this section to include tory additional UST system monitoring-related information(e.g.,additional information required by your local agency): Mas. <br /> Note regarding Section X. Pending certification of a Designated UST Operator,the following person has authority for performing the monitoring <br /> activities and maintalning leak detection equipment covered by this plan. NAME: JOB TITLE'; <br /> Tank Overfill Prevention: Unleaded Tank#1 -Audible and Visual Alarm @ 90%; Unleaded Tank#2 -Audible and <br /> Visual Alarm @ 87%; Diesel Tank- External Audible and Visual Alarm @ 90%; Waste Oil Tank-External Audible <br /> and Visual Alarm @ 90% <br /> X. PERSONNEL RESPONSIBILITIES <br /> AS OF JANU005, THE "DESIGNATED UST OPERATOR" IDENTIFIED IN SECTION Ili OF THE CURRENT UST OPERATING YL'RMIT <br /> ARY 1, 2 <br /> APPLICATION—FACILITY FORM WILL HAVE ULTIMATE AUTHORITY FOR PERFORMING THE MONITORING ACTIVITIES AND MAINTAINING <br /> LEAK DETECTION EQUIPMENT COVERED BY THIS PLAN,AND WILL PERFORM.kND DOCUMENT MINIMUM MONTHLY VISUAL INSPECTIONS <br /> OF THE FACIIATY'S UST SYSTEMS IN ACCORDANCE WITH 23 CCR§2715 ). <br /> XI. OWNER/OPERATOR SIGN'AT'URE <br /> CERTIFICATIONI X certify that the information provided herein is true and accurate to the best of my knowledge, <br /> 0 -RIOPERATOR IGNATURE REPRFSENTfNG DATE: M91 <br /> ED M90. <br /> ®operator —September 8, 2009 <br /> EWOOR NA F(print): M"- OWNER/OPERATOR TITLE: ivt9�. <br /> Randy Laney Fleet Services Supervisor <br /> (Agency Use Only) This/ l h been reviewed and: tApproved ElApproved With Conditions ❑Disapproved 1 <br /> Local Agency Signature: Date: <br /> Comments/Spccial Conditions: <br /> UN-022A-315 www.unidoes.org Rev.10/14/03 <br />