Laserfiche WebLink
07/20/2002 14:48 FAX_ _ Lo013 <br /> 2- The working surfaces on which alcoholic beverages are prepared orwhere utensils used in the preparation <br /> ❑ or service of alcoholic beverages are cleaned shall be provided with at least 108 lux(10 foot candles)of light. <br /> [CURFFL 1141701 <br /> 3- Food and utensil storage moms,refrigeration storage,toilet rooms and dressing rooms shall be provided <br /> with at least 108 lux(10 foot candles)of light_ [CURFFL 114170] <br /> 4. Light fixtures in areas where food is prepared, open food is stored or utensils are cleaned shall be of <br /> shatterproof construction or protected with shatterproof shields and be readily cleanable. [CURFFL 1141701 <br /> 5. During general cleanup activities,at least 215 lux(20 foot candles)of light measured 76 centimeters(30 <br /> ❑ inches)above the floor, repae r orlserv'edh[CURFFL 114170] <br /> alded coholic beverages are pcleaned,including,but not limited to,areas where <br /> 0, Water: <br /> ❑ 1. An adequate,protected,pressurized,potable supply of hot water at least 49 degrees Celsius(120 degrees <br /> Fahrenheit) and cold water shall be provided [CURFFL 1140953 <br /> l sinks, <br /> El t2. In sizing the water heater,ogether to determine the minilmum required recovery rate al(CURFFL dishwashing machines,etc.,are added <br /> 14095) <br /> 3. The water supply shall be from a water system approved by the health officer or the state health <br /> department. [CURFFL 1140951 <br /> P. backflow Protection: <br /> An Approved backflow prevention device shall be properly installed upstream any potential hazard between <br /> the potable water system and a source of contamination(e_g.,all threaded water outlets,mop sinks,sprayers, <br /> dishwashers, etc.). [CURFFL 1140951 <br /> Q. Indirect Waste Receptors: <br /> 1. All steam tables,Ice machines and bins,food preparation sinks,utensil washing sinks,display cases and <br /> othersimilar equipmentwith drain lines shall discharge their liquid waste through an air gap into afloorsink or <br /> other approved waste receptors. Condensate and liquid waste from food preparation equipment and sinks, <br /> utensil sinks, dishwashers, dipper wells, steam tables, ice machines, beverage dispensers, refrigeration <br /> condensers and similar equipment must be drained by indirect drainage tolnto an the sewer line if required by len floor sink or ocal <br /> approved waste receptor. Utensil washing sinks may be directly plumbed <br /> building officials. [CURFFL 1141001 [UPC 601 (b)] <br /> ❑ 2. The floor sink or other approved waste receptors should be located to provide adequate drainage of the <br /> equipment being served. Equipment should be located within fifteen (15)feet. [CURFFL 114100] <br /> ❑ 3. Floor sinks or other approved waste receptors shall be located so that they are readily accessible for <br /> inspection, leaning and repair. overflow from floor sinks shall be prevented from flowing into inaccessible <br /> areas (e.g., storage cabinet,display refrigerators,etc-). [CURFFL 114100] <br /> c <br /> ❑ 4. Local ordinances may require floor sinks to be installed flush or raised above finished floor surfaces. <br /> Contact local plumbing or building official. [CURFFL 114100] <br /> 12 <br /> Etlo 16-01-001 <br /> REVISED 02-21,02 <br />