Laserfiche WebLink
ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL A� <br /> SECTION 260519-LOW-VOLTAGE(600V OR LESS)ELECTRICAL POWER CONDUCTORS AND CABLES SECTION 260533-RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS SECTION 260553-IDENTIFICATION FOR ELECTRICAL SYSTEMS SECTION 262726-WIRING DEVICES <br /> 1.1 MATERIALS PART 1 -GENERAL 1.1 QUALITY ASSURANCE 1.1 PRODUCTS 17w <br /> A. CONDUCTORS AND CABLES: A. COMPLY WITH ANSI A13.1 AND IEEE C2. A. RECEPTACLES: DUPLEX, 125 V,20 A. <br /> 1. CONDUCTORS: COPPER. 1.1 MATERIALS 1. STRAIGHT BLADE: CONVENIENCE AND ISOLATED GROUND. <br /> 2. CONDUCTOR INSULATION: TYPE THHN/THWN-2,TYPE XHHW-2,TYPE USE AND A. METAL CONDUITS,TUBING,AND FITTINGS: 1.2 PRODUCTS 2. GFCI: FEED THROUGH. <br /> TYPE SO. 1. GRC. A. POWER AND CONTROL RACEWAY IDENTIFICATION:VINYL LABELS 3. TWIST-LOCKING TYPE WITH ISOLATED-GROUND TERMINAL. <br /> 3. MULTICONDUCTOR CABLE: METAL-CLAD CABLE,TYPE MC WITH GROUND WIRE. 2. EMT. B. PENDANT CORD-CONNECTOR DEVICES WITH EXTERNAL CABLE GRIP. <br /> 3. FMC: ZINC-COATED STEEL. B. POWER AND CONTROL CABLE IDENTIFICATION:VINYL LABELS C. CORD AND PLUG SETS: MATCH VOLTAGE AND CURRENT RATINGS AND NUMBER OF <br /> 1.2 CONDUCTOR MATERIAL APPLICATIONS 4. LFMC. CONDUCTORS TO REQUIREMENTS OF EQUIPMENT BEING CONNECTED. <br /> A. FEEDERS: COPPER. SOLID FOR NO. 10 AWG AND SMALLER;STRANDED FOR NO.8 AWG 5. FITTINGS: C. CONDUCTOR IDENTIFICATION: D. TOGGLE SWITCHES: 120/277 V, 20 A. <br /> AND LARGER. a. EMT: STEEL, SETSCREW OR COMPRESSION TYPE. SNAP-AROUND LABELS. 1. PILOT-LIGHT SWITCHES. ©2017 STARBUCKS COFFEE COMPANY <br /> B. BRANCH CIRCUITS: COPPER.SOLID FOR NO. 12 AWG AND SMALLER;STRANDED FOR b. EXPANSION FITTINGS. 2. KEY-OPERATED SWITCHES. <br /> NO. 10 AWG AND LARGER, EXCEPT VFC CABLE,WHICH SHALL BE EXTRA FLEXIBLE B. NONMETALLIC CONDUITS,TUBING,AND FITTINGS: D. FLOOR MARKING TAPE:2-INCH-(50-MM-)WIDE PRESSURE-SENSITIVE VINYL TAPE. E. WALL-BOX DIMMERS: <br /> STRANDED. 1. RNC. E. UNDERGROUND-LINE WARNING TAPE:PIGMENTED POLYOLEFIN 1. MODULAR,FULL-WAVE, SOLID-STATE UNITS WITH SLIDER CONTROL. STARBUCKS COFFEE <br /> 2. FITTINGS:MATCH CONDUIT. OR OTHER Q <br /> 1.3 CONDUCTOR INSULATION AND MULTICONDUCTOR CABLE APPLICATIONS AND WIRING 3. SOLVENT CEMENTSND ADHESIVE PRIMERS SHALL HAVE A VOC CONTENT OF F. WARNING LABELS AND SIGNS:SELF-ADHESIVE WARNING LABELS. a. INCFND ER TO ELIMI ATESCENT:SOFTPINTER ERENCCEIET SWITCH; EMI/RFI <br /> METHODS 510 AND 550 G/L OR LESS, RESPECTIVELY. b. FLUORESCENT:TRIM POTENTIOMETER FOR LOW-END DIMMING. COMPANY <br /> A. SERVICE ENTRANCE: TYPE THHNfTHWN-2, SINGLE CONDUCTORS IN RACEWAY. C. METAL WIREWAYS AND AUXILIARY GUTTERS:SHEET METAL WITH G. INSTRUCTION SIGNS:ENGRAVED. c. LED: COMPATIBLE WITH LED DRIVER OR LAMP. 2401 UTAH AVENUE SOUTH <br /> B. EXPOSED FEEDERS: TYPE THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY. SCREW COVERS. F. WALL PLATES: SEATTLE, WASHINGTON 98134 <br /> H. EQUIPMENT IDENTIFICATION LABELS:ENGRAVED, LAMINATED <br /> C. FEEDERS CONCEALED IN CEILINGS,WALLS, PARTITIONS,AND CRAWLSPACES: D. SURFACE METAL RACEWAYS: METAL, GALVANIZED STEEL,WITH SNAP-ON COVERS. 1. MATERIAL FOR WORKROOM: 206 318_1575 <br /> METAL-CLAD CABLE. E. BOXES, ENCLOSURES,AND CABINETS: ACRYLIC OR MELAMINE PLASTIC. SATIN-FINISHED STAINLESS STEEL. <br /> D. FEEDERS CONCEALED IN CONCRETE, BELOW SLABS-ON-GRADE,AND UNDERGROUND: 1. METAL OUTLET AND DEVICE BOXES:FERROUS ALLOY 2. MATERIAL FOR BAR: <br /> TYPE THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY. 2. METAL FLOOR BOXES: CAST METAL OR SHEET METAL,FULLY END OF SECTION 260553 SATIN-FINISHED STAINLESS STEEL. THESE DRAWINGS AND SPECIFICATIONS ARE <br /> E. EXPOSED BRANCH CIRCUITS, INCLUDING IN CRAWLSPACES: TYPE THHN/THWN-2, ADJUSTABLE. 3. MATERIAL FOR CUSTOMER AREAS:THERMOPLASTIC WITH COLOR OPTION PER CONFIDENTIAL AND SHALL REMAIN THE SOLE <br /> SINGLE CONDUCTORS IN RACEWAY. 3. LUMINAIRE OUTLET BOXES: NONADJUSTABLE, DESIGNED FOR ATTACHMENT OF STARBUCKS. PROPERTY OF STARBUCKS CORPORATION, <br /> F. BRANCH CIRCUITS CONCEALED IN CEILINGS,WALLS,AND PARTITIONS:TYPE LUMINAIRE WEIGHING 50 LB (23 KG). G. FLOOR SERVICE FITTINGS: MODULAR, (DUAL SERVICE IF NEEDED),WITH POWER WHICH IS THE OWNER OF THE COPYRIGHT IN <br /> THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY. 4. SMALL SHEET METAL PULL AND JUNCTION BOXES. ELECTRICAL RECEPTACLE(AND VOICE AND DATA COMMUNICATION OUTLET IF NEEDED). THIS WORK. THEY SHALL NOT BE <br /> G. BRANCH CIRCUITS CONCEALED IN CONCRETE, BELOW SLABS-ON-GRADE,AND 5. CAST-METAL ACCESS,PULL,AND JUNCTION BOXES. 1. TYPE:FLUSH REPRODUCED(IN WHOLE OR IN PART),SHARED <br /> UNDERGROUND: TYPE THHN/THWN-2,SINGLE CONDUCTORS IN RACEWAY. 6. BOXEXTENSIONS. SECTION 260923-LIGHTING CONTROL DEVICES 2. SERVICE PLATE:RECTANGULAR. WITH THIRD PARTIES OR USED IN ANY MANNER <br /> H. CORD DROPS AND PORTABLE APPLIANCE CONNECTIONS:TYPE SO, HARD 7. GANGABLE BOXES ARE PROHIBITED. 3, VOICE AND DATA COMMUNICATION OUTLET: BLANK COVER WITH BUSHED CABLE ON OTHER PROJECTS OR EXTENSIONS TO THIS <br /> SERVICE CORD WITH STAINLESS-STEEL,WIRE-MESH, STRAIN RELIEF DEVICE AT 8. HINGED-COVER ENCLOSURES: METAL. 1.1 PRODUCTS OPENING. PROJECT WITHOUT THE PRIOR WRITTEN <br /> TERMINATIONS TO SUIT APPLICATION. 9. CABINETS:GALVANIZED STEEL. A. TIME SWITCHES:ELECTRONIC, PROGRAMMABLE UNITS,WITH SINGLE CHANNEL; H. POKE-THROUGH ASSEMBLIES: BELOW-FLOOR JUNCTION BOX WITH MULTICHANNELED, CONSENT OF STARBUCKS CORPORATION. <br /> F. HANDHOLES AND BOXES FOR EXTERIOR UNDERGROUND WIRING: POLYMER ASTRONOMIC TIME, SEVEN-DAY THROUGH-FLOOR RACEWAY/FIRESTOP AND DETACHABLE FLOOR SERVICE-OUTLET THESE DRAWINGS AND SPECIFICATIONS ARE <br /> 1.4 FIELD QUALITY CONTROL CONCRETE WITH POLYMER-CONCRETE FRAME AND COVER, PROTOTYPE TESTED PROGRAMMABLE WITH MINIMUM 8 ON/OFF SET POINTS PER 24 HOUR ASSEMBLY. INTENDED TO EXPRESS DESIGN INTENT FOR A <br /> A. TESTING: BY CONTRACTOR. FOR COMPLIANCE WITH SCTE 77. SCHEDULE. 1. SERVICE-OUTLET ASSEMBLY: SURFACE TYPE. PROTOTYPICAL STARBUCKS STORE (WHICH IS <br /> 1. CONFIGURATION: INTEGRAL CLOSED BOTTOM. B. OUTDOOR PHOTOELECTRIC SWITCHES: SOLID STATE,WITH DRY CONTACTS, 2. SIZE:4 INCHES(100 MM). SUBJECT TO CHANGE AT ANYTIME)AND DO <br /> END OF SECTION 260519 2. WEATHERPROOF COVER. 15-SECOND TIME DELAY,AND METAL-OXIDE VARISTOR SURGE PROTECTION. I. MULTIOUTLET ASSEMBLIES: MANUFACTURED AND LISTED METAL RACEWAYS. NOT REFLECT ACTUAL SITE CONDITIONS. <br /> 3. COVER LEGEND:"ELECTRIC." C. DAYLIGHT-HARVESTING SWITCHING CONTROLS: CEILING MOUNTED WITH J. SERVICE POLES:TO EXTEND POWER AND VOICE AND DATA COMMUNICATION NEITHER PARTY SHALL HAVE ANY OBLIGATION <br /> ADJUSTABLE TIME DELAY AND SET-POINTS. WIRING FROM DISTRIBUTION WIRING IN CEILING TO DEVICES OR OUTLETS IN POLE NOR LIABILITY TO THE OTHER(EXCEPT STATED <br /> 1.2 RACEWAY APPLICATION D. INDOOR OCCUPANCY SENSORSDUAL-TECHNOLOGY TYPE, NEAR FLOOR. ABOVE)UNTIL A WRITTEN AGREEMENT IS <br /> A. OUTDOORS: WITH SEPARATE, EXTERNALLY MOUNTED RELAY UNIT. 1. FINISH:PAINTED. FULLY EXECUTED BY BOTH PARTIES. <br /> ELECTRICAL EXPOSED:1. O <br /> 2. CONCEALED,ABOVEGROUND: RNC,TYPE EPC-40-PVC. F. LIGHTING CONTACTORS: ELECTRICALLY OPERATED AND 3. VOCE AND DATA COMMUNICATION OUTLETS:BLANK INSERT <br /> SECTION 260526-GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS 3. UNDERGROUND: RNC,TYPE EPC-40-PVC, DIRECT BURIED. ELECTRICALLY HELD,WITH NONFUSED DISCONNECT IN STARBUCKS TEMPLATE VERSION 12017.05.18 <br /> 4. CONNECTION TO VIBRATING EQUIPMENT: LFMC. NEMA 250 ENCLOSURE. PROVIDE WITH CONTROL AND PILOT DEVICES AS K. FINISHES: <br /> 1.1 QUALITY ASSURANCE 5. BOXES AND ENCLOSURES,ABOVEGROUND: TYPE 3R OR TYPE 4. INDICATED IN PLANS. 1. CONNECTED TO NORMAL POWER SYSTEM:WHITE <br /> A. QUALITY STANDARD FOR GROUNDING AND BONDING MATERIALS AND B. INDOORS: G. EMERGENCY SHUNT RELAY: NORMALLY CLOSED, ELECTRICALLY HELD, <br /> EQUIPMENT: UL 467. 1. EXPOSED, NOT SUBJECT TO PHYSICAL DAMAGE: GRC. ARRANGED FOR WIRING IN PARALLEL WITH AUTOMATIC 2. CONNECTED TO EMERGENCY POWER SYSTEM: RED <br /> 2. EXPOSED, NOT SUBJECT TO SEVERE PHYSICAL DAMAGE: EMT. SWITCHING CONTACTS. 3. ISOLATED-GROUND RECEPTACLES: AS SPECIFIED ABOVE,WITH <br /> 1.2 PRODUCTS 3. CONCEALED: EMT, H. CONTROL CABLES: ORANGE TRIANGLE ON FACE <br /> A. INSULATED CONDUCTORS: COPPER WIRE OR CABLE. 4. CONNECTION TO VIBRATING EQUIPMENT: FMC, EXCEPT LFMC IN DAMP OR WET 1. POWER CABLES: NOT SMALLER THAN NO. 12 AWG. <br /> B. BARE COPPER CONDUCTORS: LOCATIONS. 2. CLASSES 2 AND 3 CONTROL CABLES:STRANDED-COPPER CONDUCTORS, NOT END OF SECTION 262726 <br /> 1. SOLID CONDUCTORS. 5. DAMP OR WET LOCATIONS: GRC. SMALLER THAN NO. 18 AWG. <br /> 2. STRANDED CONDUCTORS. 6. BOXES AND ENCLOSURES:TYPE 1, EXCEPT TYPE 4 STAINLESS STEEL 3, CLASS 1 CONTROL CABLES:STRANDED-COPPER CONDUCTORS, NOT SMALLER ICR �+ <br /> AL <br /> 3. TINNED CONDUCTORS. IN DAMP OR WET LOCATIONS. THAN NO. 14 AWG. ELECT <br /> 4. STRANDED BONDING CONDUCTORS. C. MINIMUM RACEWAY SIZE:3/41NCH TRADE SIZE. R <br /> 5. COPPER TAPE BRAIDED BONDING JUMPERS. D. RACEWAY FITTINGS: COMPATIBLE WITH RACEWAYS AND SUITABLE FOR USE AND END OF SECTION 260923 <br /> 6. TINNED-COPPER BRAIDED BONDING JUMPERS. LOCATION. SECTION 262816-ENCLOSED SWITCHES AND CIRCUIT BREAKERS ACIES <br /> C. CONNECTORS: BOLTED AND EXOTHERMIC-WELDED TYPE. 1. RIGID AND INTERMEDIATE STEEL CONDUIT:THREADED RIGID STEEL CONDUIT 1.1 PRODUCTS ppoFESspy <br /> D. GROUNDING ELECTRODES: FITTINGS. A. FUSIBLE SWITCHES: heK°�SSO'v Zry4�iA, <br /> 1. GROUND RODS: COPPER-CLAD STEEL, SECTIONAL TYPE WITH GROUND WELL 2. PVC EXTERNALLY COATED, RIGID STEEL CONDUITS: FITTINGS LISTED FOR ELECTRICAL 1. GENERAL DUTY,SINGLE THROW,[240-V)[600V]AC, 800 A AND SMALLER: UL 98 ENGINEERING o g <br /> AND COVER. USE WITH THIS TYPE OF CONDUIT. AND NEMA KS 1, NEMA 3R TYPE GD. 3371 Owl Street <br /> 3. EMT:COMPRESSION FITTINGS. SECTION 262416•PANELBOARDS 2. ACCESSORIES: Santa Gare,o 95054 <br /> 1.3 FIELD QUALITY CONTROL 4. FLEXIBLE CONDUIT: FITTINGS LISTED FOR USE WITH FLEXIBLE CONDUIT. ph:(408)522-5255 s <br /> A. GROUND RESISTANCE TESTING: BY CONTRACTOR-ENGAGED AGENCY. 1.1 QUALITY ASSURANCE a. EQUIPMENT GROUND KIT. h:(408)522-52M [p r <br /> END OF SECTION 260533 A. MANUFACTURER QUALIFICATIONS: ISO 9001 OR 9002 CERTIFIED. b. NEUTRAL KIT. into@adn,wt �F or[Atd a <br /> END OF SECTION 260526 c. ISOLATED GROUND KIT. Copyngnt©z0ta <br /> 1.2 PRODUCTS d. CLASS R FUSE KIT. <br /> A. GENERAL REQUIREMENTS FOR PANELBOARDS: e. AUXILIARY CONTACT KIT. <br /> 1. CONSTRUCTED TO WITHSTAND SEISMIC FORCES. f. HOOKSTICK HANDLE. <br /> 2. ENCLOSURES: SURFACE MOUNTED. g. LUGS: MECHANICAL. <br /> ELECTRICAL ELECTRICAL h. SERVICE-RATED SWITCHES. <br /> a. FRONT: HINGED COVER WITH KEY LOCK. I. ACCESSORY CONTROL POWER. <br /> SECTION 260536-CABLE TRAYS FOR ELECTRICAL SYSTEMS b. OPTIONAL ENCLOSURE FEATURES:SKIRT FOR SURFACE-MOUNTED B. NONFUSIBLE SWITCHES: <br /> SECTION 260529•HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PANELBOARDS. 1. GENERAL DUTY,SINGLE THROW,[240-V][600V]AC, 600 A AND SMALLER: UL 98 <br /> 1.1 CABLE TRAY TYPES C. DIRECTORY CARD. AND NEMA KS 1, NEMA 3R TYPE GD. <br /> 1.1 PERFORMANCE REQUIREMENTS A. LADDER. 3. INCOMING MAINS:CONVERTIBLE BETWEEN TOP AND BOTTOM 2. ACCESSORIES: <br /> LO <br /> A. DESIGN SUPPORTS FOR MULTIPLE RACEWAYS CAPABLE OF SUPPORTING B. SINGLE RAIL. 4. PHASE, NEUTRAL AND GROUND BUSES: TIN-PLATED COPPER. a. EQUIPMENT GROUND KIT. <br /> COMBINED WEIGHT OF SUPPORTED SYSTEMS AND ITS CONTENTS. C. TROUGH. 5. CONDUCTOR CONNECTORS: b. NEUTRAL KIT. r <br /> B. DESIGN EQUIPMENT SUPPORTS CAPABLE OF SUPPORTING COMBINED OPERATING a. MATERIAL: TIN-PLATED COPPER. c. ISOLATED GROUND KIT. C'V <br /> WEIGHT OF SUPPORTED EQUIPMENT AND CONNECTED SYSTEMS AND 1.2 MATERIALS b. MAIN AND NEUTRAL LUGS: MECHANICAL TYPE. Q <br /> c. AUXILIARY CONTACT KIT. <br /> COMPONENTS. A. CABLE TRAYS, FITTINGS,AND ACCESSORIES: STEEL. c. FEED-THROUGH LUGS: MECHANICAL TYPE. e. HOOKSTICK HANDLE. > LU <br /> 1. FACTORY-STANDARD PRIMER;WITH CHROMIUM-ZINC-PLATED HARDWARE. 8. PERCENTAGE OF FUTURE SPACE CAPACITY:FIFTEEN f. LUGS: MECHANICAL. <br /> 1.2 PRODUCTS 2. MILL GALVANIZED BEFORE FABRICATION;WITH PERCENT. g. ACCESSORY CONTROL POWER. 0') Q <br /> A. SUPPORT,ANCHORAGE,AND ATTACHMENT COMPONENTS: GALVANIZED HARDWARE. 7. SERVICE EQUIPMENT LABEL FOR PANELBOARDS INCORPORATING ONE OR MORE C. MOLDED-CASE CIRCUIT BREAKERS: = 1) <br /> 1. STEEL SLOTTED SUPPORT SYSTEMS WITH 3. ELECTROGALVANIZED BEFORE FABRICATION;WITH GALVANIZED HARDWARE. MAIN SERVICE DISCONNECTING AND OVERCURRENT PROTECTIVE DEVICES. V <br /> 1. THERMAL-MAGNETIC TYPE. <br /> METALLIC COATINGS. 4. HOT-DIP GALVANIZED AFTER FABRICATION;WITH B. PANELBOARD OR LOAD CENTER SHORT-CIRCUIT CURRENT RATING: FULLY RATED �Xx y <br /> 2. NONMETALLIC SLOTTED SUPPORT SYSTEMS. CHROMIUM-ZINC-PLATED HARDWARE. TO INTERRUPT SYMMETRICAL SHORT-CIRCUIT CURRENT AVAILABLE AT TERMINALS. 2. ADJUSTABLE INSTANTANEOUS-TRIP TYPE. W <br /> 3. RACEWAY AND CABLE SUPPORTS. 5. POWDER-COAT ENAMEL PAINT;WITH CHROMIUM-ZINC-PLATED LISTED SERIES RATED SYSTEM MAY BE USED IF APPROVED BY EOR TO LIMIT FAULT 3. ELECTRONIC-TRIP TYPE. <br /> 4. STEEL AND MALLEABLE-IRON CONDUIT AND CABLE HANGERS,CLAMPS,AND HARDWARE. TO BELOW 22K AIC FOR GFI BREAKERS. 4. CURRENT-LIMITING TYPE. Q = O <br /> 5. INTEGRALLY FUSED TYPE. <br /> ASSOCIATED ACCESSORIES. 6. BLACK OXIDE FINISH FOR SUPPORT ACCESSORIES AND MISCELLANEOUS 1. MAINS: LUGS ONLY. 6. GFCI TYPE. W <br /> 5. SUPPORT FOR NON-ARMORED CONDUCTORS AND CABLES IN VERTICAL HARDWARE. 2. BRANCH OVERCURRENT PROTECTIVE DEVICES FOR CIRCUIT-BREAKER FRAME 7. GFEP TYPE. <br /> U <br /> 7. BLACK. SIZES LARGER THAN 125 A: BOLT-ON CIRCUIT BREAKERS. <br /> t- <br /> CONDUIT RISERS. 8. FEATURES AND ACCESSORIES: <br /> 6. STRUCTURAL STEEL FOR FABRICATED SUPPORTS AND RESTRAINTS. B. CABLE TRAYS, FITTINGS,AND ACCESSORIES:ALUMINUM;WITH STAINLESS-STEEL C. LIGHTING AND APPLIANCE BRANCH-CIRCUIT PANELBOARDS: a. LUGS: MECHANICAL. til /�y/ w Q W O <br /> 7. MOUNTING,ANCHORING, AND ATTACHMENT COMPONENTS: HARDWARE. 1. MAINS: LUGS ONLY. b. TYPE SWD FOR SWITCHING FLUORESCENT LIGHTING LOADS. <br /> a. POWDER-ACTUATED FASTENERS. C. CABLE TRAY ACCESSORIES: 2. BRANCH OVERCURRENT PROTECTIVE DEVICES: PLUG-IN CIRCUIT-BREAKER c. TYPE HID FOR FEEDING FLUORESCENT AND HIGH-INTENSITY DISCHARGE Q <br /> b. MECHANICAL-EXPANSION ANCHORS. 1. COVERS:LOUVERED TYPE. Z T Q Q <br /> TYPE. LIGHTING CIRCUITS. 1 <br /> c. CONCRETE INSERTS. 2. BARRIER STRIPS. 3. DOORS: CONCEALED HINGE. d. GROUND-FAULT PROTECTION:INTEGRALLY MOUNTED, SELF-POWERED TYPE. H- H- (n <br /> e. CLAMPS FOR ATTACHMENT TO STEEL STRUCTURAL ELEMENTS. 3. CABLE TRAY SUPPORTS AND CONNECTORS. D. LOAD CENTERS: U U U Z Q <br /> e. ALL STEEL, SPRINGHEAD TOGGLE BOLTS. D. WARNING SIGNS: 1-1/2-INCH-(40-MM-)HIGH, BLACK LETTERS ON YELLOW W W (m 0 <br /> 1. MAINS: CIRCUIT <br /> LY. e. SHUNTTRIP. <br /> I. THREADED HANGER RODS. BACKGROUND WITH LEGEND"WARNING! NOT TO BE USED AS WALKWAY, LADDER, OR � -' � <br /> 2. BRANCH CIRCUIT BREAKERS: PLUG-IN. f. UNDENAL TIME <br /> D TRIP:35 TO 75 PERCENT OF RATED VOLTAGE WITHOUT O O <br /> B. FABRICATED METAL EQUIPMENT SUPPORT ASSEMBLIES:WELDED OR BOLTED SUPPORT FOR LADDERS OR PERSONNEL". 3. DOORS:CONCEALED HINGE. INTENTIONAL TIME DELAY. w � O' � <br /> STEEL SHAPES. 4. CONDUCTOR CONNECTORS: MECHANICAL TYPE. g. AUXILIARY CONTACTS:TWO SPDT SWITCHES. d a- LL of <br /> 1.3 SOURCE QUALITY CONTROL E. DISCONNECTING AND OVERCURRENT PROTECTIVE DEVICES: h. ALARM SWITCH: ONE NO CONTACT. <br /> END OF SECTION 260529 A. TESTED ACCORDING TO NEMA FG 1. 1. CIRCUIT BREAKERS:THERMAL-MAGNETIC TYPES. 1. KEY INTERLOCK KIT. STORE #: 10183 <br /> END OF SECTION 260536 2. GFI CIRCUIT BREAKERS: RATED FOR PERSONNEL. j. ZONE-SELECTIVE INTERLOCKING: INTEGRAL WITH ELECTRONIC TRIP. <br /> 3. AFCI CIRCUIT BREAKERS:AS REQUIRED BY CODE. PROJECT#: 27237-038 <br /> 4. OPTIONS AND TYPES AS NEEDED. k. ELECTRICAL OPERATOR. <br /> F. IDENTIFICATION: I. ACCESSORY CONTROL POWER. CASEWORK CONCEPT: <br /> 1. PANELBOARD LABELS: MANUFACTURER'S NAME AND TRADEMARK,VOLTAGE, D. MOLDED-CASE SWITCHES: ISSUE DATE: <br /> ELECTRICAL AMPERAGE, NUMBER OF PHASES,ARC FLASH HAZARD,AND NUMBER OF POLES 1. MCCB WITH FIXED, HIGH-SET INSTANTANEOUS TRIP ONLY,AND SHORT-CIRCUIT DESIGN MANAGER: <br /> SHALL BE LOCATED ON THE INTERIOR OF THE PANELBOARD DOOR. WITHSTAND RATING EQUAL TO EQUIVALENT BREAKER FRAME SIZE <br /> SECTION 260544-SLEEVES AND SLEEVE SEALS FOR ELECTRICAL RACEWAYS AND CABLING 2. BREAKER LABELS: FACEPLATE SHALL LIST CURRENT RATING, UL AND IEC INTERRUPTING RATING. LEEDO AP: <br /> 1.1 MATERIALS CERTIFICATION STANDARDS,AND AIC RATING. 2. FEATURES AND ACCESSORIES: PROGRAM MANAGER: HT <br /> A. SLEEVES: 3. CIRCUIT DIRECTORY: DIRECTORY CARD INSIDE PANELBOARD DOOR, MOUNTED a. LUGS: MECHANICAL. CHECKED BY: TG <br /> 1. SCHEDULE 40 STEEL PIPE. IN METAL FRAME WITH TRANSPARENT PROTECTIVE COVER b. GROUND-FAULT PROTECTION: REMOTE-MOUNTED AND POWERED TYPE. <br /> c. SHUNTTRIP. <br /> 2. CAST-IRON PIPE. G. ACCESSORIES: <br /> 3. GALVANIZED-STEEL SHEET FOR CONDUITS PENETRATING NON-FIRE-RATED 1. ACCESSORY SET INCLUDING TOOLS. INd. UNDENAL TIME D TRIP:35 TO 75 PERCENT OF RATED VOLTAGE WITHOUT Revision Schedule <br /> GYPSUM-BOARD ASSEMBLIES. 2. PORTABLE TEST SET: FOR TESTING FUNCTIONS OF SOLID-STATE TRIP DEVICES INTENTIONAL TIME DELAY. <br /> 4. MOLDED-PE OR-PP PIPE. WITHOUT REMOVING FROM PANELBOARD. e. AUXILIARY CONTACTS:TWO SPDT SWITCHES Rev Date By Description <br /> 5. GALVANIZED-STEEL SHEET FOR RECTANGULAR OPENINGS. 1.3 FIELD QUALITY CONTROL f. ALARM SWITCH: ONE NO CONTACT. 06-05-18 SS PERMIT SET <br /> B. SLEEVE-SEALS: A. TESTING: BY CONTRACTOR. g. KEY INTERLOCK KIT. <br /> h. ZONE-SELECTIVE INTERLOCKING: INTEGRAL WITH REMOTE GROUND-FAULT <br /> 1. EPDM RUBBER SEALING ELEMENTS. TRIP UNIT.. 1 <br /> 2. CARBON-STEEL PRESSURE PLATES. END OF SECTION 262416 L ELECTRICAL OPERATOR. 2 <br /> 3. CARBON-STEEL,WITH CORROSION-RESISTANT COATING, j. ACCESSORY CONTROL POWER. <br /> CONNECTING BOLTS AND NUTS. E. ENCLOSURES: 3 <br /> DC.. SILICONE HYDRAULIC-CEMENT GROUT. ELECTRICAL 1. INDOOR, DRY AND CLEAN LOCATIONS: NEMA 250,TYPE 1. <br /> CON SEALANTS: SHEET TITLE: <br /> 1. SINGLE-COMPONENT, SILICONE-BASED, NEUTRAL-CURING ELASTOMERIC 2. OUTDOOR LOCATIONS: NEMA 250,TYPE 3R. ELECTRICAL OUTLINE <br /> SEALANT. SECTION 262713-ELECTRICITY METERING 1.2 FIELD QUALITY CONTROL <br /> 2. MULTICOMPONENT, SILICONE-BASED LIQUID ELASTOMERIC NONSHRINKING 1.1 EQUIPMENT FOR ELECTRICITY METERING BY UTILITY COMPANY A. TESTING:BY CONTRACTOR. SPECIFICATIONS <br /> FOAM. A. UTILITY-COMPANY-COMPLIANT CURRENT-TRANSFORMER CABINETS: COMPLY WITH <br /> 3. VOC CONTENT OF 250 G/L OR LESS, REQUIREMENTS OF ELECTRICAL-POWER UTILITY COMPANY. 1.3 ADJUSTING SCALE:AS SHOWN N T.S. <br /> END OF SECTION 260544 B. METER SOCKETS:COMPLY WITH REQUIREMENTS OF ELECTRICAL-POWER UTILITY A. SET FIELD-ADJUSTABLE CIRCUIT-BREAKER TRIP RANGES. <br /> COMPANY. SHEET NUMBER: <br /> END OF SECTION 262816 E_0002 <br /> END OF SECTION 262713 <br />