Laserfiche WebLink
R. Sewage Dispos*, Grease Traps and Interceptors: "i <br /> All liquid waste, including sewage generated by a food establishment, shall be disposed of in an approved <br /> manner into either a public sewer system or to an approved on-site sewage disposal system. [CURFFL <br /> 114100] <br /> NOTE: Check with local health, building, sanitary or public works agencies for information or regulations <br /> regarding special sewerage, grease trap and interceptor requirements. <br /> IV. Ventilation: <br /> Provide adequate ventilation to remove gases,odors,steam, heat,grease,vapors or smoke from all rooms in <br /> the facility including:food preparation, scullery, toilet,janitorial, garbage and change rooms,consistent with <br /> the requirements of local building codes. [CURFFL 1141401 <br /> A. Exhaust Hoods and Ducts: <br /> ❑ 1. Mechanical exhaust ventilation shall be required at or above all commercial type deep fat fryers,broilers, <br /> fry grills, steam jacketed kettles, ranges, ovens barbecues, rotisseries, dishwashing machines and similar <br /> equipment to effectively remove gases, odors, steam, heat, grease vapors or smoke from the food <br /> establishment. Usually chemical sanitizing or under counter dishwashing machines do not require exhaust <br /> hoods. [CURFFL 1141401 <br /> a) Refer to Uniform mechanical Code, Chapter 20, section 2001 through 2004 for construction <br /> requirements. <br /> b) Refer to CCDEH Recommendations for Mechanical Exhaust Ventilation and Hood Systems <br /> for Commercial Food and Utensil Heat Processing Equipment guidelines." <br /> 2. Ventilation plans for each system shall include front and side elevations of the exhaust hood and duct <br /> details to the roof fans (both exhaust and make-up air). [See Appendix C] <br /> 3. Provide manufacturer specification sheets for exhaust fan,make-up air fan and hood filters along with the <br /> static pressure calculations. Specify the number and location of make-up air diffuser. [Complete work sheet <br /> in Appendix Cl <br /> V. Equipment Requirements: <br /> A. All new and replacement equipment shall meet or be equivalent to applicable National Sanitation <br /> Foundation(NSF)standards. Equipment design, construction and installation are subject to approval by the <br /> enforcement officer. [CURFFL 113730 & 114065] <br /> B. All utensils, display cases, windows, counters, shelves tables, refrigeration units, sinks, dishwashing <br /> machines and other equipment or utensils used in the preparation, sale, service and display of food shall be <br /> made of nontoxic, non-corrodible materials and shall be constructed, installed and maintained to be easily <br /> cleaned. [CURFFL 114090 (g)] <br /> C. Equipment shall be installed so as to facilitate cleaning under and around the equipment, and of all the <br /> adjacent surfaces. Equipment should be sealed to adjacent walls and equipment,or should be spaced away <br /> from the adjacent walls and equipment at least six(6)inches for every four(4)linear feet of equipment. [See <br /> Appendix B] [CURFFL 114090 (g)] <br /> D. All floor mounted equipment shall be placed on casters which meet or are equivalent to applicable NSF <br /> standards, minimum six(6) inch high easily cleanable legs or be completely sealed in position on at least a <br /> four(4)inch high continuously coved base or concrete curb. [See Appendix B] [CURFFL 113730& 114090 <br /> (g)] [NSF standard 2] <br /> 13 <br /> EHD 16-01-001 <br /> REVISED 02-21-02 <br />