Laserfiche WebLink
1. Refrigeration: Arfeach-in and walk-in refrigeration and freeYerGnits shall be adequate in capacity and <br /> usage to meet the needs of the proposed operation and shall: [CURFFL 113860,114080(a)&113995][NSF <br /> standard 71 <br /> a) Be specifically constructed for commercial use and shall meet or be equivalent to applicable <br /> NSF standards. Domestic model refrigerators and freezers will not be accepted. <br /> [CURFFL 1140651 <br /> b) Have shelving that is nonabsorbent, non-corrodible, easily cleanable and shall meet g )]r be <br /> equivalent to applicable NSF standards. Wood is not acceptable. [CURFFL 114090 <br /> c) Be provided with an accurate, readily visible thermometer. [CURFFL 113995] <br /> d) Drain condensate and other liquid waste in a sanitary manner to a floor sink or other approved <br /> device by an indirect connection located outside the refrigerator and freezer units. Condensate <br /> from reach-in refrigerators and freezers may be drained to a properly installed and functioning <br /> evaporator. [CURFFL 1141001 [UPC 601 (b)] <br /> e) Open into the building. [CURFFL 113730 & 114145] <br /> 2. Walk-in refrigeration and storage freezer units shall also: <br /> a) Be designed to be closed and sealed to the floor or be constructed integral with the floor. <br /> Coved bases shall be provided at the intersection of interior floors and walls. [CURFFL 114065& <br /> 114150] [NSF standard 7] <br /> b) Be flashed or sealed to walls and/or ceiling as needed to prevent rodent and vermin harborage <br /> or inaccessible areas. [CURFFL 113730 & 1140301 <br /> c) Have non-corrodible shelving that is at least six(6)inches above the floor and shall meet or be <br /> equivalent to applicable NSF standards. Wood is not acceptable. <br /> [CURFFL 114065& 114080] <br /> d) Have floor drains and floor sinks located outside units, as required. <br /> [CURFFL 114100& 114150] [UPC 601 (b)] <br /> 3. Sinks: When a sink is installed next to a wall, the integral metal backsplash shall be sealed to the wall. <br /> [Refer to page 8; B2] [CURFFL 114090] <br /> *Refer to Q1 for the indirect drainage requirements for sinks a, b and c. <br /> Hot and cold water under pressure shall be provided through a mixing valve to each compartment of the <br /> following sinks: <br /> a) Kitchen Utensil Sinks: <br /> 1. Where multi-service kitchen utensils (i.e., pots, pans, etc.) are used, a minimum 3- <br /> compartment stainless steel sink with dual integral stainless steel drain boards shall be provided. <br /> [CURFFL 114090 (b)] <br /> 2. The sink must be capable of accommodating the largest utensil to be washed and the drain <br /> boards shall be as large as the largest sink compartment. A minimum compartment size of <br /> approximately 18 x 18 x 12 inches deep will generally be adequate for most utensils. <br /> [CURFFL 114090 (b)] <br /> 3. A three (3) compartment sink maybe required within each separate section of a large food <br /> establishment which handles unpackaged foods(i.e..deli,meat,bakery,sushi bars,oyster bars, <br /> etc.). [CURFFL 114090 (b)] <br /> 14 <br /> EHD 16-01-001 <br /> REVISED 02-21-02 <br />