Laserfiche WebLink
NO. REVISION & DATE <br /> ELECTRICAL LEGEND <br /> SYMBOL DESCRIPTION <br /> SINGLE POLE 15 AMP SWITCH COMMERCIAL GRADE MOUNT AT 48" A.F.F. #AS-100 (TO TOP OF BOX) <br /> WIRELESS DIMMER SWITCH SINGLE ROCKER ECHOFLEX PTM265 <br /> MOTION SENSOR SWITCH <br /> co <br /> 15 AMP COMMERCIAL GRADE DUPLEX RECEPTACLE MOUNT AT +15" A.F.F. (U.O.N.) (TO BOTTOM OF BOX) Lo <br /> rn <br /> O U o <br /> GFI 15 AMP W/ GFCI PROTECTION WP WHERE REQUIRED MOUNT AT +15" A.F.F. (U.O.N.) (TO BOTTOM OF BOX) U <br /> 15 AMP COMMERCIAL GRADE QUADPLEX RECEPTACLE MOUNT AT +15" A.F.F. (U.O.N.) (TO BOTTOM OF BOX) �— n/ o Q <br /> :(D-H HUBBELL 8450A DUPLEX RECEPTACLE MOUNT AT +24" A.F.F. (U.O.N.) (TO BOTTOM OF BOX) <br /> U.O.N. (E) { o <br /> Q 15 AMP COMMERCIAL GRADE DUPLEX RECEPTACLE FLOOR MOUNTED A-7 EXH. V N 0 <br /> A-7 <br /> IG 15 AMP W/ ISOLATED GROUND MOUNT AT +15" A.F.F. (U.O.N.) (TO BOTTOM OF BOX) 101) <br /> ` <br /> � � NoSCONNECT SWITCH O Ga DIST (E) O <br /> 0 o' <br /> O E R.R. cn o <br /> PH TELEPHONE JACK W/ WIRING TO TELEPHONE PANEL o <br /> Q CM COMMUNICATION/COMPUTER NETWORK JACK ` (E) O 1 \\ O f n 0 m L6 <br /> v1i1� Q ^ -0 <br /> SPEAKER / � W U � o � <br /> MOS OCCUPANCY SENSOR ECHOFLEX MOS-21 FFI E Lo C .L <br /> DS DAYLIGHT SENSOR ECHOFLEX TAP-21 <br /> ERDRC WIRELESS DIMMER SWITCH CONTROLLER ECHOFLEX ERDRC-FC F SERIES65 (E) I <br /> ER6CD PHASE ADAPTIVE DIMMER ECHOFLEX ER6CD-AU-120 <br /> LCP LIGHTING CONTROL DEVICE, CAN 2 GO GW2 GATEWAY � <br /> N TV JACK W/ CABLE <br /> A-1 O <br /> ERNR SPLIT DUPLEX PLUG CONTOLLER ECHOFLEX ERNR - Al MOS WALK-11V <br /> O COOLER( <br /> LIGHTING FIXTURE SCHEDULE <br /> TYPE SYMBOL DESCRIPTION <br /> (E) V <br /> 0 F_77 (E) 2x4 92 WATT LAMP FIXTURE W/ PRISMATIC LENS, RECESSED MOUNTED. OA I ,O <br /> (E) (E) A-9 <br /> 1�) (E) SURFACE MOUNTED LIGHT, 15 WATT LIGHT FIXTURE. i <br /> © EXIT (E) ILLUMINATED LED EXIT SIGN & EMERGENCY LIGHT FIXTURE W/ POWER FROM BUILDING & EMERGENCY <br /> BATTERY BACK-UP SELECT SLC SERIES. BATTERY BACK-UP RATED FOR 90 MIN. PER CEC 1011.6.3. i PR P Q <br /> 9 o (E) WALL MOUNTED LIGHT FIXTURE, I I AR A W z <br /> OO nnn (E) WALL MOUNTED LIGHT FIXTURE, Lu <br /> F- <br /> r C�7 1x4 75 WATT LED VAPOR SEAL LIGHTING IN THE COOLER BOX J (E) (E (E) (E) w W Lu <br /> ~ <br /> © (N) 2x4 72 WATT LED L0 <br /> AMP FIXTURE W/ PRISMATIC LENS, RECESSED MOUNTED. \ <br /> T <br /> 1 O Lo <br /> � J J d) <br /> ELECTRICAL NOTES: � = <br /> O oCpC ( ) <br /> 1. ALL WIRING SHALL BE 3-12GA THWN CU-W/ 1/2" EMT UNLESS OTHERWISE NOTED. WSH 0 W Q <br /> OA A EA B <br /> U <br /> 2. ALL ELECTRICAL WIRING AND BONDING SHALL MEET C.E.C. 2016 \ E( J <br /> 3. ALL RECEPTACLES SHALL BE +15"A.F.F. UNLESS OTHERWISE NOTED, ALL CONTROLS SHALL BE MIN. OF +36" A.F.F. & MAX. OF (E) C (n Cr <br /> 48" A.F.F. A-5 z <br /> (E) MOS J ERDRC C <br /> 4. ALL EQUIPMENT GROUNDING SHALL CONFORM TO ARTICLE 250 OF 2016 C.E.0 D3 — O <br /> 5. PANEL BOARD CIRCUIT BREAKERS USED AS SWITCHES MUST BE APPROVED FOR SUCH DUTY AND BE OF THE "SWD" TYPE PER <br /> SECTION 240-83 (d) OF THE C.E.C. J _ _ }- w <br /> 6. PROVIDE PARITY SIZED GREEN GROUND WIRE IN ALL CONDUITS/BRANCH CIRCUIT HOMERUNS. Q W w U <br /> 7. ALL CONDUIT PENETRATIONS THROUGH FIRE-RATED WALLS AND FLOORS SHALL BE SEALED TO MAINTAIN FIRE-SEPARATION RATING, <br /> USE 3M FIRE BARRIER FS-195 WRAP/STRIP AT PVC PIPE PENETRATION THRU RATED WALLS. OR EQUAL PRODUCTS. ~ m <br /> (E) (E) O <br /> 8. DO NOT INSTALL ANY OUTLETS BACK TO BACK IN STUD WALLS. 2 1 <br /> 9. UNLESS OTHERWISE NOTED, DIMMER SWITCH TO CONTROL THE LIGHTING FIXTURES IN A ROOM. r <br /> 10. DRAWINGS INDICATE THE LOCATION OF DEVICES, FIXTURES AND EQUIPMENT AND THE CIRCUIT NUMBER AND PANEL DESIGNATION O <br /> WHICH SUPPLIES THEM. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETELY CONNECTING ALL ELECTRICAL <br /> DEVICES TO CIRCUITS INDICATED ON THE DRAWINGS. ERDRC2 z <br /> 11. USE 3M FIRE BARRIER CP 25 CAULK AT STEEL PIPE PENETRATION THRU RATED WALLS, OR EQUAL PRODUCT. A-3 DS J <br /> 12. PROVIDE MIN. OF 24" HORIZONTAL SEPARATION , IN BETWEEN ELECTRICAL BOXES LOCATED ON OPPOSITE SIDE OF WALLS PER <br /> C.B.C. SEC. 709.7 <br /> 13. PENETRATION ON EITHER SIDE OF RATED CORRIDOR WALLS SHALL NOT EXCEED 18" S.IN. PER PENETRATION. SERVING <br /> 14. ALL EXTERIOR LIGHTS ARE EXISTING AND ARE CONTROLLED BY PHOTO CELL. <br /> 15. T'STAT SHALL BE MOUNTED 40" TO 48" A.F.F. AREA V <br /> CAL <br /> ERIALS SHALL <br /> EW AND <br /> 16 ALL REQUIREMENITS AND TSHALL BEAR THEIRNLABEL WHEREVER ED WITH <br /> HAVERIBEEN ESTABLISHED LABEL SERVICETERS' LABORATORIES, INC. SHALL MS REGUEET LARLY z <br /> FURNISHED BY THAT AGENCY. (N) fz <br /> 17. ELECTRICAL DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH THE SIZE AND LOCATIONS OF EQUIPMENT ARE SHOWN TO <br /> SCALE WHEREVER POSSIBLE. CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL CONTRACT DOCUMENTS AND VERIFY THIS O `� <br /> INFORMATION AT THE SITE. CONTRACTOR SHALL BE RESPONSIBLE FOR LAYING OUT AND INSTALLING HIS WORK TO AVOID 0 <br /> INTERFERENCE WITH OTHER TRADES. <br /> . ALL LUMINARIES AND BALLASTS SHALL BE CERTIFIED BY THE MANUFACTURER TO THE CALIFORNIA ENERGY COMMISSION. ALL LED <br /> J <br /> FIXTURES TO BE LAMPED WITH LED LAMPS OR APPROVED EQUAL, AND HAVE AN ENERGY SAVING 'A' SOUND RATING ELECTRONIC J <br /> BALLAST OR APPROVED EQUAL UNLESS OTHERWISE SHOWN. <br /> 19. FLASH AND COUNTER FLASH ALL ITEMS PASSING THROUGH THE ROOF. O /(E) <br /> - J O U <br /> 20. PROVIDE AND INSTALL 1/2" CONDUIT FROM EACH TELEPHONE OUTLET TO ABOVE THE CEILING. VERIFY LOCATION WITH OWNER. RDRD1 0 <br /> A-1 DS (E) <br /> S LES R W <br /> J <br /> ENT Y A 7 LLJ <br /> C EXI QRpFESS/ONS <br /> (E) (E) oo�oN� Moq�O�F�c <br /> TYP.O (E) (E) (E) <br /> N0. 55088 m <br /> A-7 <br /> OF CA�Fp <br /> NOTE: <br /> 1. EXISTING LIGHTING TO REMAIN UNLESS OTHERWISE NOTED. DATE11 -15-17 <br /> 2. NEW WIRELESS DIMMER SWITCH CONTROLLER TO BE <br /> ADDED TO MAKE THREE LIGHTING ZONES. SCALE: AS SHOWN <br /> <®„ DRAWN BY: R. ORTIZ <br /> JOB NO: <br /> ELECTRICAL LEGENDS & NOTES SHEET: <br /> ELECTRICAL LIGHTING PLAN ,4CA,: E • 1 <br />