COMPLIANCE INFO 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2420
>
2300 - Underground Storage Tank Program
>
PR0231580
>
COMPLIANCE INFO 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/23/2020 9:12:47 AM
Creation date
12/21/2018 4:23:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231580
PE
2361
FACILITY_ID
FA0003963
FACILITY_NAME
TRACY 76
STREET_NUMBER
2420
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
Tracy
Zip
95377
APN
23802006
CURRENT_STATUS
01
SITE_LOCATION
2420 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Tr- <br /> SUMMARY <br /> ate: <br /> TRACY76 2420 W GRANT LINE RD TRACY a 22 2018 <br /> OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 201 CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br /> Maintenance and monitoring records for the last three years were not found on site. The 2016 monitoring system <br /> certification test results were not found on site. These records shall be maintained on site for at least three years. <br /> Monitoring records include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and <br /> maintenance records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in the <br /> field; (5) logs of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) <br /> results of inventory readings and reconciliations. Immediately locate and maintain all missing maintenance and <br /> monitoring records for the last three years on site. <br /> This is a repeat violation, Class II. <br /> 204 CCR 2712(1) Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be accessible <br /> on site at all times. Immediately locate and retain a copy on site. <br /> This is a repeat violation, Class Il. <br /> 309 CCR 2636(f)(1) Monitoring in sump / UDC failed to activate an audible and visual alarm or stop the flow product. <br /> The Bravo box floats and chains in UDC 1/2 (west), 5/6 (west), and 7/8 (east) failed to stop the flow of product at the <br /> dispenser when tested. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop <br /> the flow of product at the dispenser when it detects a leak. The service technician adjusted the floats and chains and <br /> verified functionality. <br /> This was corrected on site. <br /> This is a repeat violation, Class ll. <br /> 313 HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product-tight. <br /> Dripping fuel was observed in dispenser 7/8, liquid was observed in a light coating of the UDC beneath, and a strong <br /> fuel smell was noted at the UDC, indicating a leak in the primary piping. The rapid drip was only observed while the <br /> pump was running. All primary containment for the UST system must be tight. Immediately have a properly licensed, <br /> trained, and certified contractor repair or replace the failed component under permit and inspection of the EHD. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by June 21, 2018. <br /> Note: The liabilities and assets amounts on the Letter from the Chief Financial Officer have not not changed since <br /> 2014. Ensure that the accurate amounts are being included in the financial responsibility documents. <br /> FA0003963 PR0231580 SCO01 05/22/2018 <br /> EHD 23-01 Rev.09/22/16 Page 5 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.