My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1330
>
2300 - Underground Storage Tank Program
>
PR0515864
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2023 9:38:51 AM
Creation date
1/4/2019 10:15:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0515864
PE
2361
FACILITY_ID
FA0012355
FACILITY_NAME
GAS DEPOT #2
STREET_NUMBER
1330
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120053
CURRENT_STATUS
01
SITE_LOCATION
1330 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GAS DEPOT#2 1330 E YOSEMITE AVE, MANTECA December 28, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 123 CCR 2637.1(d), 2637.1(e) Failure to submit the"Spill Container Testing Report Form"within 30 days after the test. <br /> Spill container testing was performed on 12/28/17 and a test report was submitted on 9/11/18, over 7 months late. <br /> A copy of the test report must be submitted within 30 days of the tests. Take all necessary precautions to ensure <br /> testing and submittal of test reports are performed in a timely manner. <br /> This is a Class II violation. <br /> 201 CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br /> Maintenance and monitoring records for the last three years were not found on site. 5/16/17 secondary containment <br /> test results were not found on site at the time of inspection. These records shall be maintained on site for at least <br /> three years. Monitoring records include: (1)date and time of all monitoring or sampling; (2)monitoring equipment <br /> calibration and maintenance records; (3)results of any visual observations; (4)results of sample analysis performed <br /> a lab or in the field; (5)logs of all readings of gauges or other monitoring equipment,ground water elevations, or <br /> other test results; (6)results of inventory readings and reconciliations. Immediately locate and maintain all <br /> maintenance and monitoring records for the last three years on site and submit copies to the EHD. <br /> This is a repeat violation, Class Il. <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> On the 10/25/18 designated operator(DO)inspection report under <br /> -Section III <br /> The DO failed to add a description to all the components marked N/A or N from section VII through XI. <br /> -Section IX <br /> The DO marked N/A for UDC 9/10 and 11/12 however UDC 9/10 and 11/12 were noted to be present at the time of <br /> inspection. <br /> On the 11/25/18 designated operator(DO)inspection report under <br /> The DO monthly report was not performed within 30 days. <br /> -Section I <br /> The DO failed to mark the zip code of the facility. <br /> -Section III <br /> The DO failed to add a description to all the components marked N/A or N from section VII through XI. <br /> The designated operator failed to list the correct test date for secondary containment testing. The DO stated that the <br /> secondary containment test was last performed on 1/29/15, however the test was performed on 1/23/18. <br /> During the monthly inspection,the designated operator shall review the alarm history for the previous month, check <br /> that each alarm was documented and responded to appropriately,and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> inspections at least once every 30 days at this facility and are including all of the required information on the reports. <br /> This is a repeat violation, Class II. <br /> FA0012355 PR0515864 SCO01 12/28/2018 <br /> EHD 23-01 Rev.09/28/2018 Page 5 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.