Laserfiche WebLink
7.1 Piping Turns <br />Piping trenches should be cut with sweeping turns. Flexible <br />piping turns require specific radii depending on the pipe <br />diameter. Piping turns should not be less than: <br />.75" - 18" radius <br />1.0" - 18" radius <br />1.5" - 24" radius <br />2" - 36" radius <br />3" - 72" radius <br />7.2 Piping Crossovers <br />For flexible piping systems which have piping crossovers, <br />install the crossover supports at each intersection. 1-1/2" <br />and 2" only. <br />Note: When crossover supports are not available, a <br />minimum compacted layer of either 2" of approved pea <br />gravel or crushed stone or 4" of approved sand backfill <br />must separate each pipe. <br />7.3 Piping Supply Capacity <br />For a pressure piping system using single piping runs <br />routed in series, no more than a total of six dispensing <br />nozzles should be serviced with a 1-1/2" single piping line <br />to prevent unacceptable product flow rates. Consult OPW- <br />FCS's customer service department for flow rate <br />calculations. <br />7.4 Vent Piping Fall <br />If Vent Piping is used for vent lines, make sure there is <br />adequate fall back to the tank from the vent stack. OPW- <br />FCS requires a minimum 1/8" per foot slope for all vent lines. <br />7.5 Product Sequence <br />The dispensing product sequence will alternate from one <br />dispenser to the next when "loop -around" is used. Pipe <br />crossovers are recommended at these points to correct the <br />change in product sequence in "series" routing of pressure <br />piping systems. <br />8.0 PIPE BURIAL REQUIREMENTS <br />OPW-FCS's flexible piping and access piping are strong, yet <br />still flexible, piping systems and must be buried in such a <br />manner that they will not compress.The burial requirements <br />depend on proper pipe trenching, backfill material <br />and burial depth. Follow these instructions for warranty <br />compliance: <br />8.1 Trench Sizing <br />Piping trenches should be dug in such a <br />manner that the trench width is equal to <br />at least twice the width of all the flexible <br />pipes contained within. All piping within <br />the trench should be separated by the <br />outside diameter of the piping being �. <br />installed with a required minimum of 2" <br />(50 mm) of separation for all piping. <br />Trench turns should be sweeping rather <br />than sharp angles. The bottom of the trench should be <br />F/e.AW(ORKS <br />BY OPW FUELING CONTAINMENT SYSTEMS <br />compacted and as uniform as possible to eliminate high spots <br />to insure an even layer of bedding material under the pipe. <br />Remove all sharp rocks and debris from the trench bottom <br />before bedding material is installed. <br />8.2 Bedding & Backfill Materials <br />Approved bedding and backfill materials for .` <br />OPW-FCS's flexible piping, sumps and <br />Access piping shall meet the following <br />specifications: <br />8.2.1 Pea Gravel <br />Rounded pea gravel is permitted with a <br />minimum diameter <br />of 1/8" and a maximum diameter of 3/4". <br />8.2.2 Crushed Stone <br />Crushed stone is permitted providing it shall be washed <br />clean and be of the free flowing type with an angular stone <br />size between 1/8" and 1/2". (Meets ASTM C-33 paragraph 9.1 <br />requirements.) <br />8.2.3 Sand <br />Sand backfill is permitted providing it shall be washed clean <br />and is free flowing with a maximum content of 10% fines. <br />When backfilling, make sure sand is evenly distributed and <br />fully compacted under and fully around the piping. <br />NOTE: A minimum of 6" (152mm) of approved bedding <br />material shall be spread and compacted evenly along <br />the bottom of the piping trench. All bedding and backfill <br />material should be clean and free from ice and snow and <br />debris. Using material other than those described above <br />without written approval from OPW-FCS Products Inc. <br />will void the product warranty. <br />8.3 Flexible Pipe Sloping <br />If a continuous slope or''fall" is required from the last <br />dispenser on a piping run to the tank, then the tanks should <br />be buried at a sufficient depth and the pipe entry height into <br />the dispenser sump should be of sufficient elevation so that <br />1/8" of fall per linear foot is maintained. OPW-FCS does not <br />require its flexible pipe to be sloped in pressure systems. <br />8.3.1 Pressure Piping Systems <br />If the full system warranty is desired, the difference in <br />elevation of the piping between two dispenser sumps must <br />not be greater than 30". A pipe sensor must also be placed in <br />the terminating dispenser sump or tank sump, whichever is at <br />a lower elevation. <br />NOTE: Check your local code regulations for fall <br />requirements other than that which is previously stated. <br />8.3.2 Suction Piping Systems <br />Sloping the OPW-FCS flexible piping from the dispenser back <br />to the tank is always required for suction piping systems <br />where maintaining prime is necessary. Shallow dispenser <br />sumps are recommended for use in this application. <br />8.4 Pipe Trench Backfilling <br />Backfilling of the flexible Piping System should occur <br />