My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
121
>
2300 - Underground Storage Tank Program
>
PR0543446
>
INSTALL 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/3/2019 10:52:47 AM
Creation date
1/16/2019 2:16:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2019
RECORD_ID
PR0543446
PE
2351
FACILITY_ID
FA0024656
FACILITY_NAME
7-ELEVEN #38153
STREET_NUMBER
121
Direction
S
STREET_NAME
CENTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
121 S CENTER ST
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
631
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Man-Out-of-Hole (MOH) Straps Instructions <br /> I.GENERAL 2.3.1.2.If using deadmen other than Xerxes deadmen,check align- <br /> 1.1.These instructions for installation of anchors and straps do not ment of all anchor points to insure that they are within a tolerance of <br /> require a person to enter the hole while installing the anchor straps. ±1 inch. <br /> They supplement the Anchoring Tanks Section of the Xerxes Note:The anchor point must be a minimum of 3 inches over <br /> Installation Manual and Operating Guidelines(subsequently referred the top of the deadmen to accommodate the strap hook. <br /> to as"Installation Manual"). 2.3.1.3.Always provide sufficient clearance to allow the deadmen to <br /> 1.2.Before beginning the tank installation and installing tank hold- be set outside of the tank"shadow."See Tank Spacing subsection in <br /> down straps,read through the entire Installation Manual. Installation the Excavation Parameters section of the Installation Manual.(See <br /> instructions are also laminated onto each tank. FIGURE 2-1.) <br /> 1.3. It is the responsibility of the owner,installer and operator to <br /> comply with all federal,state and local laws,regulations,codes and <br /> safety precautions. <br /> 1.4. It is important to follow the procedures and instructions in the Tank— <br /> Installation Manual in order to safely and properly install a Xerxes —MOH strap <br /> underground storage tank and accessories.Failure to follow those <br /> instructions will void the tank warranty and may cause tank failure, <br /> death,serious personal injury or property damage, an as <br /> 1.5.Xeres must authorize, in writing and prior to tank installation, a e< –a <br /> any variation to,or deviation from,the Installation Manual and the Unman <br /> Man-Out-of-Hole Straps Instructions. <br /> 1.6.All correspondence regarding variations must be retained for <br /> any warranty claim to be valid. <br /> 1.7. If you have questions or encounter situations not covered in FIGURE 2.1 <br /> these installation instructions,contact technical support at Xeres 2,3.1.4. The top of the deadmen should be aligned to the bottom of <br /> Minneapolis, 952-887-1890. the tank. <br /> 2.ANCHORING TANKS 2.3.3.Position the deadmen so they are parallel with the centerline <br /> A CAUTION of the tank. (See FIGURE 2-2.) <br /> Failure to follow this document's instructions on proper place- toad binder <br /> ment of hold-down straps,deadmen and anchor slabs may dam- assembly _ <br /> .11111 II=11111 <br /> age the tank,cause property damage and void the tank warranty. — 1111 <br /> 2.1.Hold-Down Straps — 11111 —',,111111 <br /> 2.1.1.Only Xeres straps may be used when anchoring a Xeres MOH <br /> tank. 1111- strap 11111 <br /> 2.1.2.The only allowed locations for hold-down straps on each tank 111 / 111=11111 <br /> are marked on the tank by the arrowhead symbols ►t . 1111-111 111 — <br /> 2.1.3.Straps must be used on all marked hold-down locations. 11111 1111-11111 <br /> A CAUTION 111=1111 „ sacmd� 11111= <br /> Do not lace straps between ribs(except on 4-foot-diameter ea`tlTi <br /> p r p 11111= "_ —11111-11111 <br /> tanks).Failure to properly place straps may result in tank damage. <br /> FIGURE 2-21 <br /> 2.2. Backfill Material <br /> 2.2.1.Xerxes tanks must be installed with backfill material as 2.3.4.Place backfill between deadmen,and level backfill so it is 12 <br /> described in the Backfill Material Section of the Installation Manual, inches deep. <br /> 2.2.2.Using other than approved backfill material without prior writ- 2.3.5.When setting the tank,make sure that the tank is aligned with <br /> ten authorization from Xerxes will void the tank warranty. the deadmen. <br /> 2.3.Deadmen 2.4.Anchor Slab <br /> 2.3.1.Align the deadmen with the tank. 2.4.1. If an anchor slab is used,align(within a tolerance of±1 inch) <br /> 2.3.1.1.If using Xerxes deadmen,align(within a tolerance of±1 inch) the anchor points on the anchor slab with the marked arrowhead <br /> all anchor points with the marked arrowhead symbols"on the tank. symbols "on the tank. <br /> XERXES@ <br /> CORPORATION <br /> 7901 Xerxes Avenue South, Minneapolis, MN 55431-1288 ■ (952)887-1890 ■ Fax(952) 887-1882 ■ www.xerxescorp.com <br /> 0 2007 Xerxes Corporation xmhl 1/07ih <br />
The URL can be used to link to this page
Your browser does not support the video tag.