Laserfiche WebLink
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MCLANE FOODSERVICE DISTRIBUTION 800 PESCADERO RD, TRACY January 09, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 601 CFR 112.7 Failure of Plan to fulfill basic requirements including a cross-referencing section. <br /> The Spill Prevention, Control, and Countermeasure(SPCC)Plan does not follow the order or requirements in 40 <br /> CFR Part 112, and a cross-reference was incomplete. The provided cross reference failed to reference the location <br /> of section 112.7(g)and cross section does not reference applicable portions of sections 112.8,with the exception of <br /> sections 112.8(c)(3)and 112.8(c)(6). If you do not follow the sequence specified in 40 CFR 112 for the Plan,you <br /> must prepare an equivalent Plan and supplement it with a section cross-referencing the location of requirements in <br /> 40 CFR 112 and the equivalent Plan. Immediately amend the SPCC Plan to include a cross-reference or to follow <br /> the required sequence. <br /> This is a minor violation. <br /> 603 CFR 112.7(a)(3)Failed to adequately describe the physical layout of the facility in the Plan. <br /> The facility diagram fails to mark the contents of each fixed storage tank, only the contents of the 15,000 gallon <br /> diesel tanks are provided. The connecting piping is not provided in the facility diagram. The Spill Prevention, <br /> Control, and Countermeasure(SPCC) Plan shall include a facility diagram which must mark the location and <br /> contents of each fixed storage container and the storage area where mobile or portable containers are located. It <br /> must identify the location of and mark as"exempt" underground tanks. It must also include all transfer stations and <br /> connecting pipes, including intra-facility gathering lines. Immediately update the facility diagram to include all of the <br /> required information. Submit a legible copy of the updated facility diagram to the EHD for review. <br /> This is a Class II violation. <br /> 604 CFR 112.7(a)(3)(i)Plan failed to include oil type and storage capacity for each container. <br /> The type of oil and storage capacity for each container or an estimate of the potential number of mobile or portable <br /> containers was not provided for mobile or portable containers.The types of oil, and anticipated storage <br /> capacities;The type of oil in each fixed container and its storage capacity. For mobile or portable containers, either <br /> provide the type of oil and storage capacity for each container or provide an estimate of the potential number of <br /> mobile or portable containers,the types of oil, and anticipated storage capacities.Amend the SPCC plan to include <br /> a full discussion of applicable sections. <br /> This is a minor violation. <br /> 609 CFR 112.7(a)(3vi), 112.7(a4)Plan failed to adequately contain procedures for reporting a discharge. <br /> The Spill Prevention, Control, and Countermeasure(SPCC)Plan does not provide information and procedures to <br /> enable a person to adequately report a discharge. The name and phone number of the local CUPA was not <br /> provided in the SPCC plan. The local CUPA is the San Joaquin County Environmental Health Department. If a <br /> response plan was not submitted to the Regional Administrator,this information must be included in the SPCC Plan. <br /> Immediately amend the SPCC Plan to include this information and submit a copy of the revision to the EHD. <br /> This is a minor violation. <br /> FA0018371 PR0528616 SCO01 01/09/2019 <br /> EHD 28-01 Rev.09/27/2018 Page 5 of 8 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />