SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MCLANE FOODSERVICE DISTRIBUTION 800 PESCADERO RD, TRACY January 09, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 711 CFR 112.8(c)(6)Failed to perform scheduled tank tests or inspections by appropriately qualified personnel. <br /> The two 15,000 gallon diesel tanks were not tested on schedule by qualified personnel. The SPCC plan calls for a <br /> certified STI SP-001 integrity inspection"as soon as possible"since the tanks could not be dated. The SPCC plan <br /> or the inspection checklists in th eSPCC plan do not address the inspection of interstitial space of double walled <br /> tanks, as required by SP-001 inspection checklists. Each aboveground container shall be tested and inspected for <br /> integrity on a regular schedule and whenever repairs are made. The qualifications of personnel performing tests <br /> and inspections,frequency and type of testing and inspections that take into account container size, configuration, <br /> and design shall be determined in accordance with industry standards. Examples of these integrity tests include, <br /> but are not limited to:visual inspection, hydrostatic testing, radiographic testing, ultrasonic testing, acoustic <br /> emissions testing, or other systems of non-destructive testing. Comparison records and other records of <br /> inspections and tests must be maintained on site. Immediately conduct the necessary testing and submit a copy of <br /> the test results to the EHD, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> 720 CFR 112.8(d)(1)Failed to provide corrosion protection for buried piping. <br /> The SPCC plan does not adress buried piping in the facility. Pipiing from the two 15,000 gallon tanks was observed <br /> to go underground to dispensers. Corrosion protection was not evident and appeared to be single walled piping. <br /> Buried piping that is installed or replaced after August 16, 2002, shall be provided with a protective wrapping and <br /> coating and cathodically protected. Immediately provide all buried piping installed on or after August 16, 2002, a <br /> protective wrapping and coating and cathodic protection. <br /> This is a Class II violation. <br /> 723 CFR 112.8(d)(4)Failed to regularly inspect aboveground valves, piping, and appurtenances. <br /> The SPCC plan does not discuss this section. Facility had aboveground and underground piping. Regularly inspect <br /> all aboveground valves, piping, and appurtenances. During the inspection you must assess the general condition of <br /> items, such as flange joints, expansion joints, valve glands and bodies, catch pans, pipeline supports, locking of <br /> valves, and metal surfaces.You must also conduct integrity and leak testing of buried piping at the time of <br /> installation, modification, construction, relocation, or replacement.Amend the SPCC plan to include a discussion of <br /> all applicable sections. <br /> This is a Class II violation. <br /> FA0018371 PR0528616 SCO01 01/09/2019 <br /> EHD 28-01 Rev.09/27/2018 Page 7 of 8 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />