My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2072
>
2300 - Underground Storage Tank Program
>
PR0231426
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/17/2023 3:27:12 PM
Creation date
1/18/2019 11:57:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231426
PE
2361
FACILITY_ID
FA0004625
FACILITY_NAME
NATIONAL PETROLEUM MANTECA
STREET_NUMBER
2072
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
22202001
CURRENT_STATUS
01
SITE_LOCATION
2072 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
132
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN aOAHIN <br /> AM pEp Environmental Health Department <br /> --C C_)U i'J I <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> QUICK SHOP 2072 W YOSEMITE AVE, MANTECA December 18, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 315 HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the UDC 5/6 sump. If water could enter into the secondary containment by precipitation or <br /> infiltration, it must be removed and disposed of properly. The service technician removed 5 cups of liquid from UDC <br /> 5/6 sump. Ensure that all sumps and annular spaces are maintained free of liquid. <br /> This was corrected while inspector was on site. <br /> This is a repeat violation, Class II. <br /> 319 CCR 2635, 2637.1, 2665, 2712 No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be <br /> tested. <br /> The Diesel direct-bury spill container failed when tested. All spill containers shall have a minimum capacity of five <br /> gallons and be capable of containing a spill or overfill until it is detected or cleaned up. Immediately discontinue <br /> deposition of petroleum into this tank until the component is repaired or replaced by a properly licensed, trained, and <br /> certified contractor under permit and inspection of the EHD. The Diesel spill container had red tag#4210 affixed <br /> prior to the inspection, because this spill container is direct buried, the red tag will remain on the Diesel tank until <br /> repairs are completed. <br /> This is a repeat violation, Class II. <br /> 320 CCR 2635, 2637.2, 2665, 2712 Failure to comply with the installation, inspection, or record keeping of the overfill <br /> prevention. <br /> The Mechanical overfill prevention system used as the overfill prevention system is not currently functional on the <br /> 100 octane, 110 octane, 87 (1) product, 87 (2) product, and 91 product UST system because it is set above 95%. <br /> Immediately repaired or replaced by a properly licensed, trained, and certified contractor under permit and <br /> inspection of the EHD. If the failed component can't be replaced immediately, there is a possibility that the 100 <br /> octane, 110 octane, 87 (1) product, 87 (2) product, and 91 product UST system may be red tagged to prevent fuel <br /> inputs. The operator, Pete Chahoud, is aware of the failures and provided a statement to the inspector stating that <br /> he would repair and retest with passing results by 1/18/19 or he would be red tagged. <br /> This is a Class II violation. <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements. <br /> This UST system was found to be illegally abandoned. No person shall abandon an UST system without complying <br /> with the requirements of HSC 25298. Immediately obtain a permit from the EHD to remove this UST system. A <br /> "Failure to Obtain a Permit" penalty applies. <br /> The operator provided a statement to close this violations while the inspector was on site. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> An inspection report was provided to the facility operator on the day of inspection. The report was amended by <br /> FA0004625 PR0231426 SC333 12/18/2018 <br /> EHD 23-01 Rev.09/28/2018 Page 8 of 9 Underground Storage Tank Program OR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page