cl` <br /> HOW TO LOCATE THE POSITION OF THE <br /> 71SO AT 95%TANK CAPACITY Measuring Stick <br /> The length of the upper tube and the placement of <br /> the 71 SO valve body determine the shut-off point. <br /> Following the standard instructions for the OPW <br /> 71SO will provide for initial shutoff at 95%. In all <br /> cases, the upper tube length must be a minimum of I Tk <br /> 6-1/2"plus the length of the riser pipe. All length - <br /> measurements are in inches. Riser Pipe t <br /> with Face (A) <br /> INSTRUCTIONS Seal Adaptor I To Tank (S) <br /> h 1 Top(I.D.) To Tank <br /> 1.)Find tank capacity(in gallons)from tank I; <br /> ��'�3 calibration chart provided by tank manufacturer. I ' Bottom <br /> it-1 8.-1 2.j Calculate 95%of capacity. -�- <br /> 6-1/2" <br /> 3.)Locate the 95%volume number on the tank <br /> calibration chart. <br /> kC6 31q 4.) Find the dipstick number(X)which corresponds Figure 1 <br /> to the 95%tank volume. And,find the dipstick <br /> number(Y)which corresponds to the EXAMPLE <br /> 1 100%volume. 1.)For an Owens-Corning Model G-3 FiberglassO <br /> Tank Calibration Chart: <br /> 5.)Subtract the dipstick number(X)from the tank Tank Capacity- 10,000 gal., nominal 9,403 gal. <br /> = IZ• S diameter(Y)to find the upper tube reference NOTE: Use actual capacity only <br /> number(Z). <br /> (Y)-(X) _(Z) 2.)95%of actual tank capacity= 0.95 x <br /> 6.)Subtract 2"from(Z)to find the upper tube depth 9403 gal. =8933 gal. <br /> (C). 3.)The closest number which is less than 8933 gal. <br /> (Z)-2"= C Is 8910 gal.Choosing the closest number less <br /> than 95% of actual capacity ensures that the <br /> 7 is C less than 6-1/2"? initial shutoff will occur when the tank is no more <br /> than 95%full. <br /> NO Upper tube length is C plus the distance <br /> from the top of the Face Seal Adaptor 4.)The calibration chart reading of 8910 gal. <br /> installed on the riser pipe to the inside,top corresponds to a dipstick measurement of 82". <br /> lip of the storage (A). <br /> 5.) Dipstick number(X)=82" <br /> Upper Tube Length = C + (A) Tank diameter(Y)=92" <br /> (Y)-(X)= (Z) (92 82"= 10") <br /> YES Upper tube length is 6-1/2" plus the riser (Z)= 10" <br /> r � � pipe measurement(A). <br /> Upper Tube Length=6-112"+ (A) C=84, <br /> NOTE: You must find the actual tank capacity 7.) Is 8"less than 6-1/2"? <br /> number that correlates to the 6-1/2" + (A)depth <br /> for the station records. This number may also NO Measure the distance from the top of the <br /> be used for the purposes of calibrating an FSA-400 Face Seat Adaptor installed on the <br /> electronic tank level system. riser pipe to the inside,top lip of the storage <br /> tank and obtain measurement(A). <br /> Registered T.M -Owens Corning Fiberglass Corporation Upper tube length=C+ (A) <br /> 64 <br />