My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AURORA
>
1207
>
3500 - Local Oversight Program
>
PR0543429
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 7:41:03 PM
Creation date
1/31/2019 2:27:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0543429
PE
3528
FACILITY_ID
FA0005340
FACILITY_NAME
J C TRUCKING
STREET_NUMBER
1207
Direction
S
STREET_NAME
AURORA
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
14734404
CURRENT_STATUS
02
SITE_LOCATION
1207 S AURORA ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
175
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 <br /> Based o the aquifer thickness, the conductor casing will be founded approximately half way <br /> through t e aquitard. The conductor casing borehole is then drilled to the target depth into the <br /> aquitard. Drilling is slow as 15-inch augers are needed. Further_; it is critical that the boring be <br /> { advanced slowly and carefully so as to not pass through the aquitard.'' If this were to happen, <br /> a then the t orehole would have to be abandoned and re-drilled elsewhere. <br /> ii <br /> �L <br /> Once the target depth is reached, the conductor casing is placed downhole. The conductor <br /> casing is steel, approximately 9-inches in diameter, and generally comes in either 10 or 20-foot <br /> segments. It is lowered into the borehole one segment at a timer An on-site welder then welds" <br /> i each seg ent as it is lowered downhole. The welding is criticil in order to have a property <br /> sealed casing. Further, working with the heavy steel casing is awkward; a crane is oftentimes <br /> needed fdr lowering and placing the casing. <br /> i Once the proper length of conductor casing is placed, the conductor{casing. is there grouted. <br /> Given tht annulus size, the grout quantity and time required to place the grout is significantly <br /> more thar for a typical monitoring well. <br /> Following grouting, the grout must have sufficient time to set before we can come back and drill <br /> through t ie conductor casing. If.we do not wait long enough, the;impact of the augers banging' <br /> on the c ising during drilling might displace and crack the grout_ This would jeopardize the <br /> integrity the conductor casing seal. This downtime results in additional mob/demob costs. <br /> E. <br /> Additiona ly, what I have done in the past is hydrostatically test the conductor casing to test its <br /> integrity. Generally, this is accomplished by filling the casing' with ,water to near the top, <br /> measuring it accurately, and then checking one to two days later. A drop .in water level would <br /> generally suggest a breach in the casing somewhere. <br /> Once p perly placed and constructed, the deeper wells cane then be drilled through the <br /> conducto casings. The drill rig is brought back to the site and the two deeper wells drilled <br /> through a conductor casings. Once the target depths are reached, the wells are constructed <br /> per typi I standards. When grouted, the interior of the conductor casing serves as the well, <br /> 'annulus", The conductor casings are oftentimes completed as well monuments, with locking lids <br /> r casings. This provides excellent protection to the PVC well <br /> outfitted the top of the conduCto 9 p <br /> casing. <br /> As you n see, the installation of deeper wells requires a fairly rigid and time consuming <br /> i protocol. However, this is very important_ We must take proper measures to ensure that we <br /> have not nadvertently created a conduit between an uncontaminated aquifer and one of known <br /> high love contamination. 'I <br /> I hope thi it this information is helpful. Please feel free to call if you have any questions. <br /> E Dan <br /> E <br /> cc: M . Lori Duncan, Sart Joaquin County Environmental Health <br /> templatelfa�rans.doc <br /> I <br /> E <br /> c <br /> i <br />