Laserfiche WebLink
Well Drill Out or <br /> Designation Pressure Justification <br /> Grout <br /> MW-3A PG Groundwater (GW) was non-detect (ND) for chemicals of concern, <br /> impacted soil at 10' was addressed by well screen interval <br /> MW-313 Drill Out Well passes through impacted soil at 32.5' that was not <br /> addressed by well screens, no confirmation samples <br /> MW-3C Drill Out Well passes through impacted soil at 32.5' that was not <br /> addressed by well screens, no confirmation samples <br /> EW-3 PG GW ND, impacted soil at 10' addressed by well screen <br /> MW-4A Drill Out GW impacted during last sampling event which was during active <br /> groundwater extraction (GWE) period <br /> MW-413 Drill Out GW monitored by the well is ND, but this deeper screened well <br /> passes through impacted water monitored by MW-4A <br /> MW-4C Drill Out GW monitored by the well is ND, but this deeper screened well <br /> passes through impacted water monitored by MW-4A <br /> MW-7A Drill Out Impacted soil addressed by well screen, but last monitoring event <br /> had impacted GW, no post remediation samples. <br /> MW-713 Drill Out Passes through impacted GW monitored by MW-7A and impacted <br /> soil at 30' not addressed by well screen intervals. <br /> MW-613 Drill Out ND soil, but GW impacted last event during GWE period. <br /> MW-6C Drill Out GW ND, but passes through MW-613 impacted GW <br /> EW-813 Drill Out ND soil, but GW impacted last event during GWE period. <br /> EW-96 Drill Out Impacted GW <br /> MW-813 Drill Out Impacted GW <br /> MW-20A Drill Out Impacted GW <br /> MW-20B Drill Out Monitored GW ND, but well passes through impacted GW interval <br /> of MW-20Aa. <br />