Laserfiche WebLink
f r <br /> KYLE CHRISTIE <br /> PAGE 2 <br /> 1711 E. Yosemite, Manteca ARCO Facility #6020 <br /> PHS/EHD contact - Michael Infurna <br /> The underground storage tanks at this facility are scheduled to be removed. The exact <br /> removal date has not yet been determined. The work will probably coincide with the street <br /> widening planned for Yosemite Street in Manteca. The tank closure plan, when submitted to <br /> PHS/EHD, will include a work plan to over-excavate the new tank pit area and to take <br /> confirmation soil samples. This corrective action requires an executive summary and a public <br /> participation period of 1 to 30 days prior to implementation. This site is to remain on an <br /> annual groundwater monitoring and sampling schedule. Upon review and concurrence with the <br /> tank closure report sent to both PHS/EHD and CVRWQCB, documenting successful <br /> remediation of the contaminated soil by over-excavation and destruction of the three monitoring <br /> wells, site certification/closure will be granted. <br /> 7906 N. El Dorado St., Stockton ARCO Facility #2130 <br /> PHS/EHD contact - Michael Infurna <br /> The addendum to the Final Remedial Plan has been received by PHS/EHD and is currently <br /> undergoing review. <br /> The remedial system is currently on line as of last week. <br /> The additional monitoring wells will be installed pending access to the off site locations. <br /> Access agreements were mailed out last month. <br /> Several monitoring wells at the site need to be upgraded or maintained due to disrepair. This <br /> will be taken care of in the next quarter. <br /> 441 W. Charter Way, Stockton ARCO Facility #2168 <br /> PHS/EHD contact - Michael Infurna <br /> The addendum to the Final Remedial Plan has been received by PHS/EHD and is undergoing <br /> review. The current quarterly report has not yet been completed but the upgradient well is still <br /> showing the second highest levels of contamination. A historic search by ARCO on the use of <br /> the property to the west of the site to determine if there were any former underground storage <br /> tanks would be helpful. A file review report completed by EMCON will be submitted to <br /> PHS/EHD. <br /> The underground storage tanks at this site are scheduled to be removed but <br /> the exact date and whether they will be replaced has not yet been determined and is <br /> dependent on a new lease agreement between ARCO and the property owner. <br /> The new legislation regarding commingling plumes was briefly discussed. S6108 requires a <br /> trial period with the City of Blythe but the legislation may be helpful to situations where there <br /> are documented co-mingling plumes. <br /> 800 E. Kettleman, Lodi ARCO Facility 2076 <br /> PHD/EHD contact - Mary Meays <br /> The unauthorized release report filed for this site in September 1994 for a drive off spill was <br /> discussed. The disposition of the absorbent and the contaminated soil from the cleanup will be <br /> included in the next quarterly report or in a separate letter. The third quarter status report was <br /> received at the meeting. <br />