COMPLIANCE INFO 1989 - 2002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
COMPLIANCE INFO 1989 - 2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 1:12:34 PM
Creation date
2/8/2019 9:46:02 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1989 - 2002
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
210
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SVWRCB,January 2002 - Page 5 of <br /> 6. PIPING SUMP TESTING - <br /> Test Method Developed By: ❑Sump Manufacturer Vndustry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: n Pressure ❑Vacuum} Hydrostatic <br /> O Other(Specify) <br /> TcstE9U4WUsed: Al MAI. Z5gr&e W Z3u 44crcrt. EquipmentRes"on: Nrerr."►T6 <br /> Sump# 97 Sump# Z_ -rY Sump#i - Samp#-I[ - - - <br /> Sump Diameter. q7 10 Z�� 4:z•I <br /> Sump Depth: Sar. ss " 5 30s <br /> Sump Material: t S ► LASS t' [a5'S <br /> Height from Tank Top to Top of <br /> Highest Piping P�ation 3�'r <br /> Height from Tank Top to Lowest f, ,r / \ <br /> Electrical Penetration: Z �S�r 2-6 11 <br /> Condition of sump prior to testing. 66D 0 o o;/ n d15 4 o0 <br /> Portion of Sump Tested ►► 3g!Y 3 '� ," <br /> Does turbine shut down when r Yes O No ❑NA <br /> sump sensor detects either product ®Yes D No'-Q NA IdYes D No [INA ■Yes ❑No DNA <br /> or water?' <br /> Turbine shutdown response time?' 27"3-/Se"a /T•v3 5zr .V r 2 S;n C l'S'7 <br /> Is system progratmned for fail-safe O Yeas ❑No D NA <br /> shutdown?� ®Yes-Q No DNA Yes ❑No [INA 2 Yes C1 Nb ❑NA <br /> Was fail-safe verified to be ❑Yes III No ❑NA '111 p <br /> �2. Yes','!No ONS D Yes Ilk No DNA ❑Yes 61,4o ❑NA <br /> Operati <br /> Wait time between applying i <br /> pressurelvacuam/water and starting <br /> test: 10" /•-3 10 M 1 o ID M 10 <br /> Test Start Time: `�: �. :�� !S;7-0 <br /> Initial Reading(It,): t.e bd f/ v v r p, 'r rj,voo 4" <br /> Test End Time: r <br /> Final Reading OZF): 0,00i <br /> Test Duration: / '. /1i(11 / 12 at 1.7 12 Al W 12 m l ij <br /> Change in Reading(I�rR;) fj,oa r n <br /> Pass/Fail Threshold or t • •� `(j ddZ rr t ,Uo�r/ p, 2" D•u oz�' <br /> 9 <br /> Was sensor renwvexl for testing 1 Yes, D No 11 NAW Yes ❑No ❑NA WYes ❑No ❑NA G Yes D No DNA <br /> Was sensor ply mplaced and 111'Yes D No ❑NA lWYes ❑No O NA IeYcs ❑No ❑NA If Yes ❑No ❑NA <br /> verified functional after testin . <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up forfailed tests) <br /> 'If the testing method does not test the entire depth of the sump,specify how much of the sump was tested Methods not testing the <br /> entire sump should only be used if the monitoring system provides fail-safe turbine shutdown. (See SWRCB LG-160) <br /> 'With the submersible pump running,place the sensor in product(discriminating sensors should also be placed in water). The time <br /> between placing the sensor in product and the turbine shutting down is the response time. This should be done if the secondary <br /> containment testing method used does not test the entire volume of the sur <br /> This information is not needed if the entire sump is tested <br />
The URL can be used to link to this page
Your browser does not support the video tag.