Laserfiche WebLink
Advanced <br /> GeoEnvironmental, Inc. =0 <br /> 07 August 2000 <br /> AGE-NC Project No. 96-0232 <br /> Mr. Michael Kith <br /> San Joaquin County Public Health Services -Environmental Health Division <br /> 304 East Weber Avenue,Third Floor <br /> Stockton,CA 95202 - <br /> Subject: Gasoline And Diesel Product Line Testing <br /> FLAG CITY CHEVRON-6421 Capitol Avenue,Lodi, CA 95242 <br /> Dear Mr. Kith: <br /> On behalf of Mr. Richard Bokides,property owner of Flag City Chevron located at 6421 Capitol Avenue <br /> (site), Lodi, California (See Figure 1), Advanced GeoEnvironmental, lnc. (AGE) is hereby requesting to <br /> schedule a standardized pressure test on each primary fuel dispensing product line and a helium tracer test <br /> on each secondary fuel dispensing product line with the San Joaquin County Public Health Services - <br /> Environmental Health Division(PHS-EHD). <br /> On 31 July 2000, Mr. Doug Wilson of the PHS-EHD informed AGE in a telephone conversation that the <br /> PHS-EHD was preparing a letter directive to the Flag City Chevron facility to conduct a"helium tracer test' <br /> on all fuel dispensing product lines. Furthermore,Mr. Wilson iterated that the Flag City Chevron facility <br /> needed to install secondary containment pans beneath each fuel dispenser to satisfy the existing State of <br /> California underground storage tank(UST)laws. <br /> In telephone conversations with Champions Precision Tank Testing(CPTT)and Tanknology,both State of <br /> California certified to perform tank and product line integrity tests, AGE was informed that helium testing <br /> performed on dual walled product line system would only identify a leak at the point of breach in the <br /> secondary product line containment system and not the primary product lines; furthermore, there would be <br /> no way to identify where the breach was in the primary product line from a helium tracer test. Both CPTT <br /> and Tanknology recommended a standard pressure test as the best alternative for evaluating the integrity of <br /> the primary product lines and a helium test to evaluate the integrity of the secondary product line. <br /> Therefore, AGE recommends that a standard pressure test be performed on each primary product line to <br /> satisfy annual tank testing requirements; a helium tracer test should be performed only on the secondary <br /> product lines to satisfy the above mentioned PHS-EHD directive. AGE believes that the proposed standard <br /> pressure test will locate whether or not there are breaches in the primary product line and a helium tracer test <br /> will be tested on the secondary product lines to identify areas of fuel leakage.All fuel leakage detected from <br /> the above mentioned primary and secondary product line tests would require immediate damage repairs to <br /> the associated product line(s)in accordance with San Joaquin County guidelines. <br /> 4005 North Wilson Way. Stockton. California 95205 <br /> Telephone (209)467-1006 FAX(209)467-11 19 <br />