FIELD DOCUMENTS AND WORK PLANS 1988
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WAGNER
>
200
>
2900 - Site Mitigation Program
>
PR0009002
>
FIELD DOCUMENTS AND WORK PLANS 1988
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2019 9:26:14 PM
Creation date
2/22/2019 2:35:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
FIELD DOCUMENTS
FileName_PostFix
AND WORK PLANS 1988
RECORD_ID
PR0009002
PE
2960
FACILITY_ID
FA0004040
FACILITY_NAME
SPX COOLING TECHNOLOGIES INC
STREET_NUMBER
200
Direction
N
STREET_NAME
WAGNER
STREET_TYPE
AVE
City
STOCKTON
Zip
95215
APN
14331007
CURRENT_STATUS
01
SITE_LOCATION
200 N WAGNER AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
316
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MCTC Response: <br /> Additional sample locations 5-23 and S-24 will be included in <br /> Work Plan revisions ajnd specifications for sampling efforts. <br /> Analytical requirements will be modified to add chemical <br /> constituents and physical characteristics suggested, and delete <br /> waste extraction tests as suggested since these tests are <br /> unnecessary for characterization purposes. <br /> The term "mutually acceptable maximum background level" <br /> referenced in this citation did not refer to the average <br /> background levels calculated in the 1985 Soil Assessment Plan <br /> Report. In this citation, the intended meaning was that MCTC <br /> wished to work toward establishing a total concentration for each <br /> constituent which would "trigger" performance of waste extraction <br /> tests. Since the waste extraction tests will be deleted for <br /> characterization purposes, this statement will be deleted also. <br /> DNS Comment: <br /> Page 4-6 Table 4-1: <br /> Add locations "S-23" and "S-24" to Table 4-1. Analysis to <br /> be performed on samples collected at the surface and at <br /> 0.25, 0.5, 1.0, and 2.0 feet below land surface. <br /> Table 4-1 should also indicate the additional sampling <br /> depths specified above for locations N-5, N-6, N-7 , and N-9. <br /> MCTC Response: <br /> Table 4-1 will be revised to incorporate additional sample <br /> locations and depths for S-23 and S-24 . Table 4-1A will be added <br /> for specifying deeper samples from locations N-5, N-6, N-7 and <br /> N-9. <br /> DHS Comment: <br /> Page 4-7 Last paragraph, first sentence: <br /> After the word "horizontal" , add "and vertical". <br /> MCTC Response: <br /> The sentence will be revised to read as follows: "Results of the <br /> Phase III groun6water assessment did not fully define the <br /> horizontal and vertical extent of the contaminant plume in the <br /> aquifer. " <br /> DS Comment: <br /> Page 4-8 ^op of page_, first sentence: <br /> After "necessary to plan", add "and monitor" . <br /> 11654 4 <br />