Laserfiche WebLink
TABLE 9 <br /> ANALYSIS OF CHROMIUM CONCENTRATIONS AND REDUCTION POTENTIAL <br /> FORMER MARLEY COOLING TOWER SITE <br /> STOCKTON,CALIFORNIA <br /> Page 1 of 3 <br /> Fourth Quarter 2012 Percent ChangeinConcentration Description of Trend for Key Indicator Parameters Potential for <br /> Monitoring Concentration(µ Concentrations fromg/L) has been Further <br /> Maximum Oxidation Reduction Recommendation` <br /> Well Total Chromium Total Chromium Below 50µg/L Chromium Iron Manganese Total Organic Carbon Potential Chromium <br /> Chromium VI Chromium VI Since e Reduction <br /> Injection Area Wells <br /> Below WQO after spike Revert to sitewide compliance monitoring <br /> MW-6 6J <0.5 -98% -100% 1/2011 in 10/2010 Stable above WQO Stable above WQO Low Positive Goal achieved programd <br /> Above WQO,below Low;gradual decrease <br /> MW-8 195 195 -74% -72% Exceeds baseline Near baseline Stable below WQO following 2008 Positive Low Continue performance monitoring per the MRP <br /> injections <br /> MW-9 6J <0.5 -82% NM Before 2008 Stable below WQO Above WQO, Increasing since 7/2010 Low Positive Goal achieved Continue performance monitoring per the MRP <br /> increasing <br /> 0 o Fluctuating,currently Above WQO, Revert to sitewide compliance monitoring <br /> MW-101 4J <0.5 -100% -100% 1/2009 Stable below WQO below WQO increasing Low Positive Goal achieved pro amd <br /> Stable above WQO, Above WQO,possibly Possibly decreasing, <br /> MW-102 570 568 -53% -47% Exceeds Low Positive Moderate Continue performance monitoring per the MRP <br /> decreasing increasing currently below WQO <br /> 4/2011 Above WQO, Above WQO, Spike after 2010 Revert to sitewide compliance monitoring <br /> MW-104(S-2) 4J <0.5 -100% -100% Stable below WQO Positive Goal achieved d <br /> (5/2008) increasing trend increasing trend injections,decreasing program <br /> 0 o Fluctuating above Fluctuating above Revert to sitewide compliance monitoring <br /> MW-105 <10 <0.5 -100% -100% 4/2008 Stable below WQO WQO WQO program Low Positive Goal achieved d <br /> Stable above WQO, Below WQO and Slightly above baseline <br /> MW-106 155 154 -69% -69% Exceeds Low Positive Low Continue performance monitoring per the MRP <br /> below baseline baseline (ND)but below WQO <br /> MW-204(S-8) 346 322 -92% -91% Exceeds Above WQO, Slightly above WQO Previously increased, Low Positive Low Continue performance monitoring per the MRP <br /> decreasing trend and baseline and possibly decreasing <br /> MW-205(S-7) 340 331 -52% -51% Exceeds Above WQO, Slightly above baseline Baseline(ND) Low Positive Low Continue performance monitoring per the MRP <br /> decreasing trend and WQO <br /> Increased after 2010 <br /> 12/2010 Increased after 2010 Revert to sitewide compliance monitoring <br /> MW-206 5J NS -100% -100% (7/2010) Stable below WQO injections,slightly injections,decreasing Low Possitive Goal achieved program d <br /> below WQO <br /> 0 o Fluctuating near and Above baseline but Near baseline below Revert to sitewide compliance monitoring <br /> MW-207 50 48.2 -67% -68/o at WQO equal to the WQO below WQO WQO Low Positive Low program d <br /> 0 o Slightly above WQO Fluctuating;currently <br /> MW-208 <10 <0.5 -100% -100/o Before 2008 Stable below WQO and baseline above WQO and Low Positive Goal achieved Continue performance monitoring per the MRP <br /> baseline <br /> Above WQO and Near baseline below Revert to sitewide compliance monitoring <br /> MW-300 11 10.50 -63% -48% Before 2008 Stable below WQO baseline WQO Low Positive Goal achieved program d <br /> ° ° Decreasing,below Slightly above WQO Increased above WQO <br /> MW-301 24 23.2 -88/o -83/0 7/2012 Low Positive Low Continue performance monitoring per the MRP <br /> WQO and baseline in 2nd quarter 2012 <br /> MW-303 3J <0.5 -97% -100% Before 2008 Stable below WQO Near baseline Above baseline Spiked in 2009,since Positive Goal achieved Continue performance monitoring per the MRP <br /> decreased <br /> Revert to sitewide compliance monitoring <br /> TW-12 4J <0.5 -88% -100% Before 2008 Stable below WQO Above baseline Above baseline Variable,decreasing Positive Goal achieved d <br /> program <br /> TW-14e <10 <0.5 -97% NM 1/2009(Before Stable below WQO Above baseline Above baseline Low Positive Goal achieved Continue performance monitoring per the MRP <br /> 2008) <br /> 1/2009(Before Decreasing from high <br /> TW-17 3J <0.5 -99% NM 2008) Stable below WQO Above baseline Above baseline after injections Positive Goal achieved Continue performance monitoring per the MRP <br /> EW-1 <10 <0.5 -100% NM 5/2008 Stable below WQO Slightly above baseline Above baseline Low Positive Goal achieved Continue performance monitoring per the MRP <br /> TW-13 262 254 -97% -97% Exceeds Above baseline Above baseline Above baseline Low Positive Low Continue performance monitoring per the MRP <br />