Laserfiche WebLink
TABLE 9 <br /> ANALYSIS OF CHROMIUM CONCENTRATIONS AND REDUCTION POTENTIAL <br /> FORMER MARLEY COOLING TOWER SITE <br /> STOCKTON,CALIFORNIA <br /> Page 2 of 3 <br /> Percent Change m Description of Trend for Ke Indicator Parameters <br /> Fourth Quarter 2012 Concentration p � Y Potential for <br /> Monitoring Concentration(µ Concentrations fromg/L) has been Further <br /> Maximum Oxidation Reduction Recommendation` <br /> Well Total Chromium Total Chromium Below 50µg/L Chromium Iron Manganese Total Organic Carbon Potential Chromium <br /> Chromium VI Chromium VI Since e Reduction <br /> Injection Area Wells(Continued) <br /> TW-15 37 36.8 -61% -63%° 1/2009 Possibly increasing, Slightly above WQO Above baseline, <br /> Low Positive Low Continue performance monitoring per the MRP <br /> below WQO and baseline possibly decreasing <br /> TW-16 4J <0.5 -94% NM 1/2009 Stable below WQO Slightly above WQO Above baseline Low Positive Goal achieved Continue performance monitoring per the MRP <br /> (4/2008) and baseline <br /> I-11 305 303 -40% -40% Exceeds Possibly decreasing Near WQO,slightly Baseline(ND) Low Positive Low Continue performance monitoring per the MRP <br /> from high in April 2012 above and baseline <br /> Below WQO and Below WQO and Revert to sitewide compliance monitoring <br /> MW-1 6 NA -67% -24% Before 2008 Stable below WQO baseline baseline program Low Positive Goal achieved d <br /> MW-2 20 19.0 -57% -53% Before 2008 Stable below WQO Below WQO,slightly Baseline(ND) Low Positive Goal achieved Revert to sitewide compliance monitoring <br /> above baseline program <br /> Above WQO and Increased after 2008 <br /> MW-213(I-7) 2,880 2,710 -60% -62% Exceeds Fluctuating baseline and 2010 injections, Low Positive Low Continue performance monitoring per the MRP <br /> now decreaseing <br /> MW-214(I-8) <10 <0.5 -100% -100% 7/2010 Stable below WQO Below WQO and near Decreasing trend,above Low Positive Goal achieved Revert to sitewide compliance monitoring <br /> baseline WQO program <br /> Below WQO near Above baseline(ND) Revert to sitewide compliance monitoring <br /> MW-320 <10 <0.5 -100% -100% Before 2008 Below WQO baseline but below WQO Low Positive Goal achieved program d <br /> Exceeds <br /> ° ° (hexavalent Decreasing relative to Near WQO and Increased in fourth <br /> MW-321 (I-9) 57 49.5 -93% -95% chromium highs in 2010 baseline Above baseline quarter 2012 Positive Moderate Continue performance monitoring per the MRP <br /> slightly below <br /> WQO) <br /> MW-322 15 14.9 -76% -75% 4/2010 Below WQO Above WQO and Above baseline Low Positive Goal achieved Continue performance monitoring per the MRP <br /> baseline <br /> Near WQO and Increase in fourth Revert to sitewide compliance monitoring <br /> MW-323 <10 6.05 -100% -40% Before 2008 Stable below WQO quarter 2012,above Low Positive Goal achieved d <br /> baseline WQO program <br /> MW-324(I-10) 16 15.2 -62% -9% Before 2008 Stable below WQO Above WQO and Baseline(ND) Low Positive Goal achieved Continue performance monitoring per the MRP <br /> baseline <br /> Below WQO and near Near WQO and below Revert to sitewide compliance monitoring <br /> MW-361 <10 NA NM NM Before 2008 Stable below WQO Low Positive Goal achieved d <br /> baseline baseline program <br /> MW-4475 716 700 -91% -91% Exceeds Above WQO, Near WQO Below WQO Low Positive Low Continue performance monitoring per the MRP <br /> decreasing trend <br /> MW-447D 2,300 2,250 -34% -28% Exceeds Stable above WQO Near WQO and Non-detect Increased in fourth Positive Moderate Continue performance monitoring per the MRP <br /> baseline quarter 2012 <br /> MW-4485 2,480 2,470 -5% -3% Exceeds Stable above WQO Near WQO and Non-detect Low Positive Low Continue performance monitoring per the MRP <br /> baseline <br /> MW-448D 2,930 2,860 -77% -77% Exceeds Above WQO, Below WQO and Non-detect Low Positive Low Continue performance monitoring per the MRP <br /> decreasing trend baseline <br /> MW-449S 1,750 1,720 -35% -34% Exceeds NA NA NA NA NA NA New well with only 2 samples;continue <br /> performance monitoring per the MRP <br /> MW-449D 6,320 6,610 0% 0% Exceeds NA NA NA NA NA NA New well with only 2 samples;continue <br /> performance monitoring per the MRP <br /> MW-450S 4,400 4,360 0% 0% Exceeds NA NA NA NA NA NA New well with only 2 samples;continue <br /> performance monitoring per the MRP <br /> MW-450D 85 85 -15% -3% Exceeds NA NA NA NA NA NA New well with only 2 samples;continue <br /> performance monitoring per the MRP <br /> Decreased but above Near WQO and Increase in second half <br /> EW-3 11,400 12,000 -69% -64% Exceeds WQO baseline of 2012 Low Positive Low Continue performance monitoring per the MRP <br /> MW-4 1,050 1,030 0% 0% Exceeds Stable above WQO Slightly above WQO Non-detect Low Positive Low Continue performance monitoring per the MRP <br />