My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
COMPLIANCE INFO 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 2:26:33 PM
Creation date
2/26/2019 12:19:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
268
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page 4 of <br />5. SECONDARY PIPE TESTING <br />Test Method Developed By: ❑ Piping Manufacturer 0 Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: 0 Pressure ❑ Vacuum ❑ Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Calibrated Gauges <br />Piping Run # 87-1 P Piping Run # 87-2 P <br />Equipment Resolution: 0.00" <br />Piping Run #87 siphon Piping Run # 91 P <br />Piping Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Piping Manufacturer: <br />Smith <br />Smith <br />Smith <br />Smith <br />Piping Diameter: <br />3.00" <br />3.00" <br />3.00" <br />3.00" <br />Length of Piping Run: <br />150.00 <br />155.00' <br />15.00' <br />140.00' <br />Product Stored: <br />87 <br />87 <br />87 <br />Method and location of <br />piping -run isolation: <br />Test Boot <br />Test boot <br />Test boot <br />Test boot <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />5 min <br />5 min <br />5 min <br />5 min <br />Test Start Time: <br />10:00am <br />10:00am <br />10:00am <br />10:00am <br />Initial Reading (RI): <br />5.00psi <br />5.00psi <br />5.00psi <br />5.00psi <br />Test End Time: <br />11:00am <br />11:00am <br />11:00am <br />11:00am <br />Final Reading (RF): <br />5.00psi <br />5.00psi <br />5.00psi <br />5.00psi <br />Test Duration: <br />1 hour <br />1 hour <br />1 hour <br />1 hour <br />Change in Reading (RF -Rt): <br />0.00" <br />0.00" <br />0.00" <br />0.00" <br />Pass/Fail Threshold or <br />Criteria: <br />0.002" <br />0.002" <br />0.002" <br />0.002" <br />Test Result: <br />0 Pass ❑ Fail <br />0 Pass ❑ Fail <br />0 Pass ❑ Fail <br />Pass ❑ Fail <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.