Laserfiche WebLink
SWRCB, January 2002 <br />8. FILL RISER CONTAINMENT SUMP TF.STTNG <br />Page 10 of <br />Facility is Not Equipped With Fill Riser Containment Sums <br />❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: <br />❑Sump Manufacturer <br />0lndustry Standard ❑Professional Engineer <br />[]Other (Specify) <br />Test Method Used: <br />❑Pressure <br />❑ Vacuum <br />ElHydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: TS -STS <br />Equipment Resolution: 0.00° <br />Fill Sump # 91 <br />Fill Sump # 87-1 <br />Fill Sump # 87-2 <br />Fill Sump # 87 Slave <br />Sump Diameter: <br />39.00" <br />39.00" <br />39,00" <br />39.00" <br />Sump Depth: <br />72.00° <br />72.00° <br />72.00" <br />72.00° <br />Height from Tank Top to Top of <br />18.00" <br />18.00" <br />18.00" <br />18.00" <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />ao.00" <br />ao.00" <br />ao.00" <br />ao.00" <br />Condition of sump prior to <br />Clean dry <br />Clean dry <br />Clean dry <br />Clean dry <br />testing: <br />Portion of Sump Tested <br />Highest penetration <br />Highest penetration <br />Highest penetration <br />Highest penetration <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Wait time between applying <br />pressure/vacuum/water and <br />5min <br />5min <br />5min <br />5min <br />starting test: <br />Test Start Time: <br />Initial Reading (R,): <br />SEE INCON RESULTS <br />SEE INCON RESULTS <br />SEE INCON RESULTS <br />SEE INCON RESULTS <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />15min <br />15min <br />15min <br />15min <br />Chane in Reading (RF-Ri): <br />Pass/Fail Threshold or Criteria: <br />0.002" <br />0.002" <br />0.002" <br />0.002° <br />Test Result: <br />O Pass ❑ Fail <br />O Pass ❑ Fail <br />O Pass ❑ Fail <br />0 Pass ❑ Fail <br />Is there a sensor in the sump? <br />O Yes []No <br />O Yes ❑ No <br />0 Yes ❑ No <br />0 Yes ❑ No <br />Does the sensor alarm when <br />either product or water is <br />[]Yes ❑ No ONA <br />OYes ❑No ONA <br />[]Yes []No ONA <br />[]Yes []No ONA <br />detected? <br />Was sensor removed for testing? <br />O Yes No ❑NA <br />[]Yes No ❑NA <br />OYes ❑No [INAOti'es <br />[]No❑ NA <br />Was sensor properly replaced and <br />OYes ❑No 0 N <br />OYes 0 N 0 N <br />OYes ONO ❑NA <br />OYes ❑No [INA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follotir-mp forfailed tests) <br />